ABB - Installation Products 168FLR1-C0230 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.

ABB Installation Products 168FLR1-C0230 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 783786468584


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Molded Current Limiting Fuse Housing (SKU: 168FLR1-C0230) is designed for reliable protection in medium-voltage electrical systems. Rated for a nominal fuse voltage of 8.3kV, this housing is engineered to accommodate current limiting fuses, providing essential overcurrent protection. It features two integrated capacitive test ports, facilitating safe and efficient testing of fuse status and system integrity without requiring removal of the fuse or housing. The compact design of this small housing ensures efficient use of space within electrical enclosures. It is suitable for cable insulation diameters ranging from 0.805 to 1.060 inches (20-27mm). For conductor connections, the housing supports aluminum conductors of 1 AWG stranded/compressed or 1/0 AWG solid/compact sizes. This product is part of ABB's Installation Products catalog, known for its dependable electrical components. Its construction and specifications are geared towards ensuring operational safety and system reliability in industrial and utility applications where precise overcurrent protection is paramount.
  • Nominal Fuse Voltage Rating: 8.3kV
  • Fuse Test Port: Two Capacitive Test Ports
  • Cable Insulation Diameter: 0.805 - 1.060 inch / 20-27mm
  • Aluminum Conductor Size: 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact
  • Manufacturer: ABB - Installation Products

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
Aluminum
Material
EPDM-Rubber
Series
168FLR1
Size
Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.

168FLR1-B0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.

168FLR1-B0260

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

168FLR1-A0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

168FLR3-B0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact

168AFLR3D0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

274FLR3-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.

168FLR3-B0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.

Frequently Asked Questions

What is the DC 15-minute withstand voltage?

The DC 15-minute withstand voltage is 53kV DC.

What is the AC one-minute withstand voltage?

The AC one-minute withstand voltage is 34kV AC.

What is the impulse withstand rating of the Fused Elbow?

The impulse withstand (BIL) rating is 95kV (1.2 x 50 microsecond wave).

What types of conductors are compatible with the compression lugs?

Copper compression lugs are for copper conductors only. Bi-metal compression lugs with universal aluminum barrels are suitable for copper or aluminum conductors.

What items are included in each Fused Elbow kit?

Each kit contains an elbow connector housing, a crimp connector, a probe lug, lubricant tubes, installation instructions, and a crimp chart.

Is the Elastimold Fused Elbow suitable for submersible applications?

Yes, the Elastimold Fused Elbow is fully sealed and submersible, making it suitable for underground distribution systems.

What industry standards does the Fused Elbow meet?

The Elastimold® Fused Elbow meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47 standards.

What is the symmetrical interrupting capability?

The symmetrical interrupting capability of the Fused Elbow is 50,000 Amp.

What is the nominal and maximum fuse voltage?

The nominal fuse voltage is 8.3kV, and the maximum rated fuse voltage is 10kV for the 15kV voltage class.

What is the DC 15-minute withstand voltage?

The DC 15-minute withstand voltage is 53kV DC.

How to Install the 168FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe and proper installation of the 168FLR Loadbreak Fused Elbow Connector, including cable preparation, assembly, and neutral connections.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush, Crimp tool (for compression lug), Probe Wrench (supplied with kit), Torque-limiting Allen Wrench (supplied with kit)

Supplies needed:

168FLR Cable Half Housing, 168FLR Elbow Half Housing, Fuse (supplied with kit), Compression Lug (supplied with kit), Probe (supplied with kit), Probe Connector (supplied with kit), Hose Clamp (supplied with kit), Lubricant (supplied with kit), No. 14 AWG / 2.5mm copper wire (for grounding), Appropriate ground connector, Optional 200ECS Cold Shrink Cable Seal

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility with mating parts. Failure to follow these instructions will result in damage to the product and serious or fatal injury.

  2. Prepare Workspace and Tools

    Gather all required tools and supplies. Maintain cleanliness throughout the procedure. Check package contents to ensure they are complete and undamaged. Check all components to ensure proper fit with the cable and/or mating products. Verify threads by threading the probe into the compression lug; if resistance is encountered, check for damage and replace the component.

  3. Cable Training and Jacket Removal

    Using the bushing centerline as reference, cut excess cable off 20 inches minimum beyond the bushing. Remove the jacket from the excess cable length remaining AND the distance of “A” (11-1/2” for FLR-1) + 7-3/8” from the bushing centerline. If a Cable Seal kit is used, follow its instructions; otherwise, unwrap and fold the Concentric Neutral wires back over the jacket, and bind them. Squarely cut off the cable a distance of “A” from the bushing centerline, leaving 7-3/8” minimum of cable to terminate.

  4. Conductor Preparation and Lug Installation

    Cut 1-1/8” from the cable end, squarely, taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor. Crimp the unthreaded end of the compression lug to the conductor (refer to the crimp chart packaged with the lug for recommended tool information). Start the crimp at the crimp line mark and rotate 180 degrees for each successive crimp. Carefully wipe excess inhibitor from the outside of the lug and cable.

  5. Insulation Shield Removal and Cleaning

    Remove the insulation shield 5-1/2” from the end of the lug. Bevel the insulation end a maximum of 1/8”. Thoroughly clean the insulation to remove all traces of conductive residue.

  6. Lubricate and Insert Cable into Elbow Half

    Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. DO NOT SUBSTITUTE lubricant. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface “A”. This allows the fuse to be tightened before bottoming on the rubber.

  7. Install and Hand Tighten Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. HAND TIGHTEN. CAUTION: The fuse stud will fracture if over-torqued. Pull the housing up against the bottom of the tightened fuse.

  8. Assemble and Lock Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position by tightening the setscrews using the special torque-limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  9. Assemble Elbow Halves and Insert Probe

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half. The cuff of the cable half will overlap the elbow half by 3/4”. Make sure that the probe connector faces the opening of the fused elbow half and that the two test points are in line with each other. Insert the probe into the probe connector; it may be necessary to push on the cable to get the probe to line up with the fuse. Start the threads by hand, taking care not to cross-thread the probe. To tighten, use the special torque-limiting allen wrench supplied; tighten until the wrench bends and remains bent.

  10. Secure with Hose Clamp

    Position the hose clamp as shown in the diagram and tighten it. DO NOT OVERTIGHTEN.

  11. Connect Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eye. Finish installing the 200ECS jacket seal if used. Twist all neutral wires, exercise care not to damage grounding eyes, and connect to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  12. Prepare for Connection to Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Do not operate by hand; use a full insulated “hotstick” type tool for connection.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.