ABB - Installation Products 168FLR1-B0260 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.

ABB Installation Products 168FLR1-B0260 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 783786496914


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168FLR1-B0260 Molded Current Limiting Fuse Housing is a compact, high-voltage protection solution engineered for medium-voltage distribution systems. Rated for 8.3kV nominal fuse voltage, this housing accommodates cable insulation diameters from 0.635 inch to 0.905 inch (16-23mm) and supports both stranded/compressed 3/0 AWG and solid/compact 4/0 AWG aluminum conductors. The unit features two capacitive test ports for safe, non-invasive voltage verification during maintenance or fault diagnostics, eliminating the need for direct contact with live components. The small housing design optimizes space in switchgear and control panels while maintaining robust dielectric integrity, ensuring reliable performance in confined installations. This fuse housing is ideal for utility, industrial, and commercial applications requiring precise current limiting and reliable fault interruption in medium-voltage circuits. The molded construction ensures consistent performance under thermal and mechanical stress, while the aluminum conductor compatibility aligns with standard utility-grade installations. The product is designed for compatibility with ABB and third-party current-limiting fuse links, providing a versatile solution for 8.3kV class systems. Order by SKU 168FLR1-B0260 for direct replacement or new installations.
  • Rated for 8.3kV nominal fuse voltage
  • Accommodates cable insulation diameters 16-23mm (0.635-0.905 inch)
  • Supports 3/0 AWG stranded/compressed and 4/0 AWG solid/compact aluminum conductors
  • Two capacitive test ports for safe, non-invasive voltage verification
  • Compact design optimizes space in switchgear and control panels

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
EPDM-Rubber
Material
Molded Construction, Aluminum
Mounting Type
Small Housing for Switchgear/Control Panels
Series
168FLR1
Size
Cable Insulation Diameter 0.635-0.905 inch (16-23mm)
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.7900 L
Package Weight (Metric)
3.5340 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact. Bi-Metal Connector.

168FLR1-C5260

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact. Bi-Metal Connector.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

168FLR1-A0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

168FLR3-B0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact

168AFLR3D0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

274FLR3-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.

168FLR3-B0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR3-C0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed.

168AFLR3C0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed.

Frequently Asked Questions

What are the main applications of the Elastimold 168FLR?

The 168FLR combines full-range current-limiting fusing with 15kV hot stick operable, loadbreak elbow switching. It protects light duty underground distribution systems, including sub-loops and radial taps.

How do I select the correct housing size for the 168FLR?

Select the housing size (H Code) based on the desired fuse. Size 1 is for 3-45A 8.3kV and 6-20A 15.5kV fuses, while Size 3 is for 65-80A 8.3kV and 3-45A 17.2kV fuses.

What is the operating frequency rating for the 168FLR?

The operating frequency rating for the 168FLR is 50/60 Hz.

What are the AC and DC withstand voltage ratings?

The product has a 34kV AC one-minute withstand rating and a 53kV DC 15-minute withstand rating.

What items are included in each 168FLR kit?

Each kit contains one elbow connector housing, one crimp connector, one probe lug, four tubes of lubricant, installation instructions, and a crimp chart.

What types of conductors are compatible with the compression lugs?

Copper compression lugs are suitable for all copper conductors only. Bi-metal compression lugs with a universal aluminum barrel are suitable for both copper or aluminum conductors.

What cable insulation diameters are compatible with the 168FLR?

Compatible cable insulation diameters range from 0.575 in to 1.220 in, depending on the specific W Code selected.

Is the 168FLR Loadbreak Fused Elbow submersible?

Yes, the 168FLR Loadbreak Fused Elbow is fully sealed and submersible.

What is the current rating range for the 168FLR?

The current rating for the 168FLR ranges from 3 to 80 Amps.

What is the symmetrical interrupting capability of the 168FLR?

The 168FLR has a symmetrical interrupting capability of 50,000 Amps. It also features full-range current-limiting fusing with 50kA interrupting capability.

How to Install the 168FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the installation and initial setup of the 168FLR Loadbreak Fused Elbow Connector, designed to provide in-line current limiting fusing and terminate UD cable.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Torque-limiting Allen Wrench, Wire brush, Crimp tool, Hotstick

Supplies needed:

Lubricant, No. 14 AWG Copper Wire, Grounding Connector, Optional 200ECS Cold Shrink Cable Seal

  1. De-energize Apparatus and Inspect Components

    De-energize all apparatus in the work area before beginning installation or removal of parts, except for test point caps and indicators. Inspect all parts for damage, correct rating, and compatibility with mating parts. Verify proper fit of all components with the cable and/or mating products. Check threads by hand-threading the probe into the compression lug; if resistance is encountered, check for damage and replace the component.

  2. Perform Cable Training

    Cut excess cable 20 inches minimum beyond the bushing, referencing the bushing centerline. If using, slide the optional 200ECS Cold Shrink Cable Seal onto the cable. Remove the cable jacket for 'A' + 7-3/8 inches from the bushing centerline ('A' is 11-1/2" for FLR-1, 15-3/4" for FLR-3). If using a Cable Seal kit, follow its instructions; otherwise, unwrap and bind concentric neutral wires back over the jacket. Squarely cut the cable a distance of 'A' from the bushing centerline, leaving 7-3/8 inches minimum for termination.

  3. Prepare the Cable End

    Cut 1-1/8 inches squarely from the cable end, avoiding conductor nicks. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Crimp the unthreaded end of the lug to the conductor per the crimp chart, starting at the crimp line and rotating 180 degrees for successive crimps. Wipe excess inhibitor from the lug and cable. Remove insulation shield 5-1/2 inches from the lug end. Bevel insulation end 1/8 inch max. Thoroughly clean insulation to remove all conductive residue.

  4. Lubricate and Insert Cable into Cable Half Housing

    Apply the supplied lubricant to the outside of the connector, the cable insulation, the conductive shield, and the cable entrance end of the Fused Elbow cable half. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A' of the housing. This allows the fuse to be tightened before bottoming on the rubber.

  5. Install the Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and hand-thread it into the cable connector. CAUTION: Hand tighten the fuse only; over-torquing will fracture the fuse stud. Pull the cable half housing up against the bottom of the tightened fuse.

  6. Assemble the Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the mating bushing. Lock the probe connector in position and tighten the setscrews using the special torque-limiting Allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  7. Assemble Elbow Half Housing and Probe

    Apply lubricant to the elbow half. Assemble the elbow half to the cable half, ensuring the cable half cuff overlaps by 3/4 inch. Verify the probe connector faces the elbow half opening and test points align. Insert the probe into the probe connector; push cable if needed for alignment. Hand-start probe threads, avoiding cross-threading. Tighten probe with the special torque-limiting Allen wrench (insert short end into probe hole, tighten until wrench bends and remains bent). Position and tighten the hose clamp as shown. DO NOT OVERTIGHTEN.

  8. Connect Concentric Neutral

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through each grounding eye on the elbow housing and cable housing. Twist the wire tightly, taking care not to damage the grounding eyes. Finish installing the 200ECS jacket seal if it was used. Twist all neutral wires together, exercising care not to damage the grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the neutral wires for elbow operation.

  9. Connect Elbow to Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Operate the connection using a full insulated 'hotstick' type tool, following the operating instructions. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.