Authorized ABB Distributor (Installation Products)
ABB - Installation Products 164J2-4 - 200 Amp, 15kV, 2-Point Junction Rubber only with out straps

ABB Installation Products 164J2-4 200 Amp, 15kV, 2-Point Junction Rubber only with out straps

UPC: 783786550517


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 164J2-4 is a 200 Amp, 15kV 2-point junction component designed for medium-voltage electrical distribution systems. This unit is constructed from a fully shielded, molded rubber housing with 100% peroxide-cured insulation and conductive EPDM materials, ensuring reliable performance in demanding environments. The 2-point configuration provides two distinct connection interfaces for termination and distribution of electrical power. Rated for 200 Amp continuous and loadbreak operation, the 164J2-4 meets ANSI/IEEE Standard 386 for 15kV class distribution systems. Key electrical ratings include 8.3kV phase-to-ground operating voltage, 14.4kV maximum phase-to-phase voltage, 95kV BIL impulse withstand, and 34kV AC one-minute withstand. The junction is designed for submersible applications, including subsurface, vault, or padmount installations. This model is supplied as the rubber component only, without straps, and is intended for use with compatible Elastimold® elbow connectors. Typical applications include sectionalizing, looping, tapping, and equipment bypass in medium-voltage distribution networks. Refer to ABB installation manuals for specific compatibility and installation guidelines.
  • 200 Amp, 15kV rated medium-voltage junction component
  • Fully shielded, molded rubber housing with peroxide-cured EPDM insulation
  • 2-point configuration for dual connection interfaces
  • Designed for submersible, subsurface, vault, or padmount applications
  • Compatible with Elastimold® elbow connectors for sectionalizing and tapping

Specifications

Application
15 kV, 200 Amps
Current Rating
200 A
Material
Rubber
Series
164J2-4
Type
Junction 2-Point
Voltage Rating
15kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, Left Parking Stand.

J4-6226-15-L

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, Left Parking Stand.
Universal Mounting Bracket Prepack, 15/25kV, Includes Stainless Steel Channel Bracket, Stainless Steel Angle Bracket, and Hardware: Hex Head Cap Screws, Lockwashers and Hex Nuts.

1501-114

Universal Mounting Bracket Prepack, 15/25kV, Includes Stainless Steel Channel Bracket, Stainless Steel Angle Bracket, and Hardware: Hex Head Cap Screws, Lockwashers and Hex Nuts.
200 Amp, 15/25kV, Straight Receptacle Pin Contact and Crimp Barrel Assembly. Wire Size #2 Stranded.

151-SRC-1AX

200 Amp, 15/25kV, Straight Receptacle Pin Contact and Crimp Barrel Assembly. Wire Size #2 Stranded.
3-way Junction Hardware Package Brackets and Straps only

164J3-6

3-way Junction Hardware Package Brackets and Straps only
200 Amp, 15kV, 4-Point Junction rubber only without straps.

164J4-4

200 Amp, 15kV, 4-Point Junction rubber only without straps.
4-Way Junction Hardware package Brackets and Straps only

164J4-6

4-Way Junction Hardware package Brackets and Straps only
2-Way Junction Hardware package Brackets and Straps only

164J2-6

2-Way Junction Hardware package Brackets and Straps only
Non LoadBreak Parking Stand, 304 Stainless Steel, Length 2 inch. Assembly includes Bracket, Spring and Rivet

151-PS

Non LoadBreak Parking Stand, 304 Stainless Steel, Length 2 inch. Assembly includes Bracket, Spring and Rivet

Frequently Asked Questions

What are the key specifications of the 164J2 junction?

The 164J2 is a 15kV, 200 Amp Loadbreak 2-Way Junction with a fully shielded, fully submersible molded rubber housing.

What is the operating voltage for the 15kV class junction?

For the 15kV voltage class, the operating voltage is 8.3kV Phase-to-Ground, with a maximum phase-to-phase of 14.4kV.

What is the momentary and fault close rating?

The momentary and fault close rating is 10kA Symmetrical for 10 cycles.

What is the continuous and loadbreak current rating?

The continuous and loadbreak current rating is 200 Amp.

What is the corona extinction voltage rating?

The corona extinction voltage is 11kV AC at 3pC sensitivity.

What are the AC and DC withstand voltage ratings?

The one-minute AC withstand voltage is 34kV, and the 15-minute DC withstand voltage is 53kV.

What is the impulse withstand rating of the junction?

The impulse withstand rating is 95kV BIL (1.2 x 50 microsecond wave).

What standard does the 164J2 junction meet?

The 164J2 junction meets ANSI/IEEE Standard 386, Latest Revision.

What tilt mounting angles do the universal brackets support?

The universal brackets provide tilt mounting angles from 0° to 90° in 15° increments.

What are the primary applications of the 164J2 junction?

The 164J2 junction can be used for sectionalizing, looping, tapping, and equipment bypass on 15-kV class distribution systems.

How to Install the ELASTIMOLD 160DRG/167DRG Insulated Cap with Ground Lead

This guide provides step-by-step instructions for the safe installation of the ELASTIMOLD 160DRG and 167DRG insulated caps, designed for insulating, shielding, and watersealing 15kV class loadbreak bushing interfaces. All apparatus must be de-energized during installation. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

Estimated time: 30m

Tools needed:

Eight-foot fully insulated hotstick

Supplies needed:

ELASTIMOLD 160DRG or 167DRG Insulated Cap with Ground Lead, ELASTIMOLD approved lubricant

  1. Connect Grounding Wire

    Connect the free end of the electrostatic grounding wire to the system ground. Ensure enough slack is left for hot-stick operation of the insulated cap. CAUTION: Train the grounding wire so it does not contact the bushing interface during operation. WARNING: If the ground lead disconnects during operation, do not attempt to reattach without first pulling the insulated cap off the bushing with the hotstick.

  2. Prepare and Lubricate the Cap

    Remove the protective cover from the insulated cap. Lubricate the cap’s internal mating surface using only the supplied or ELASTIMOLD approved lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful to this product and its mating products. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when the cap is not in use.

  3. Attach Cap to Bushing

    Firmly attach the hotstick to the insulated cap's pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing. Push the cap home with a fast, firm, straight motion, making certain it is fully mated with the locking ring seated. Detach the hotstick from the insulated cap.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.