ABB Installation Products 161LRJS-C-5230 15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable…
UPC: 075114185509
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV, 200 Amp continuous and loadbreak operation
- Accommodates cable insulation diameters from .805" to 1.060"
- Bi-metal compression lug for copper or aluminum conductors
- Fully shielded, submersible molded rubber housing
- Meets ANSI/IEEE Standard 386 with 95kV BIL impulse rating
Specifications
Amperage Rating | 200 A |
Application | The 161LRJS is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection Type | Loadbreak Jacket Seal Elbow Connector |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal, Insulated |
Material | Bi-Metal Compression Lug |
Series | 161LRJS-C |
Size | Cable Insulation Diameter 0.805 inch to 1.060 inch |
Size | 0.805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Built in Cable Jacket Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector and Jacket Seal |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K656YSR-H0230
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
161LRJS-C-5240
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
755LRTP-M0330-DRG
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
161LRJS-C-5270
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug
161LRJS-C5260
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
755LRTP-L0270-DRG
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
162LR-B-2250
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
162LR-B-2230
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Copper Compression LugFrequently Asked Questions
What is the maximum cable insulation diameter for this elbow connector?
This elbow connector is designed to accommodate cable insulation diameters ranging from .805 inches to 1.060 inches.
What wire size is compatible with the bi-metal compression lug?
The bi-metal compression lug is suitable for #1 stranded wire size.
What is the current rating of the ABB 161LRJS-C-5230 connector?
The ABB 161LRJS-C-5230 connector has a current rating of 200 Amps.
What is the voltage rating for this loadbreak elbow connector?
This loadbreak elbow connector has a voltage rating of 15kV.
How to Install Elastimold 161LRJS/162LRJS Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 161LRJS and 162LRJS Loadbreak Elbow Connectors on UD cable, covering cable preparation, elbow assembly, and neutral connection.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Crimp tool, Wire brush, Wire strippers, Cable cutting tool, Hotstick (for operation)
Supplies needed:
161LRJS or 162LRJS Elbow Connector Kit (includes housing, compression lug, probe, lubricant, 3 sealing strips), Separate copper wire (No. 14 AWG / 2.5mm), Appropriate ground connector, Vinyl tape, UD cable
- Prepare the Cable
DANGER: Ensure all apparatus is de-energized during installation. Train the UD cable to provide 24-26 inches of slack beyond the bushing centerline. Remove the outer jacket 7 3/4 to 8 inches back. Unwrap neutral wires past the centerline and cut the cable squarely. Wrap one mastic strip around the jacket, embed neutral wires, then wrap a second (and third if needed) mastic strip, covering with vinyl tape. Remove insulation shield and insulation, then wire brush bare aluminum conductors. Immediately install the compression lug, aligning its threaded hole with the bushing bore, and crimp it according to the chart. Bevel the insulation end 1/8 inch maximum and thoroughly clean the insulation.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Connect the Concentric Neutral
Pull the hood over the concentric neutral seal area on the cable by pulling the tabs or rolling the seal down. Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow, twisting it tightly without damaging the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for future elbow operation.
- Connect the Elbow to the Bushing Plug
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. WARNING: Lubricate only if the transformer and elbow are known to be de-energized. Do not operate by hand; use a fully insulated hotstick type live-line tool as per operating instructions to securely connect the elbow to the bushing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.