ABB - Installation Products 15PCJ1M2360 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.

ABB Installation Products 15PCJ1M2360 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786861996


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15PCJ1M2360 is a 15kV power cable joint designed for medium-voltage applications requiring reliable, long-term connections. This joint accommodates cable insulation diameters between 1.370 and 1.630 inches, making it suitable for AWG 750 solid copper conductors. The single-piece housing simplifies installation while ensuring consistent performance in industrial environments. Engineered for compatibility with standard 15kV systems, this joint provides a secure, insulated interface for splicing cables without compromising electrical integrity. Ideal for power distribution, substations, and industrial facilities where downtime is costly, the 15PCJ1M2360 meets stringent electrical and mechanical requirements. Its design minimizes installation time and reduces the risk of faults, ensuring operational reliability. ABB’s Installation Products line delivers trusted solutions for critical infrastructure, and this joint is no exception.
  • Rated for 15kV applications with solid copper AWG 750 conductors
  • Accommodates cable insulation diameters from 1.370 to 1.630 inches
  • Single-piece housing for simplified installation and consistent performance
  • Designed for medium-voltage power distribution and industrial use
  • Compatible with standard 15kV system configurations

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
750 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

15PCJ2N1410-N1380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 750.

15PCJ2M1410-L1360

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.

69TCJS4-5-4

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.

25PCJ1M1300

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ1H1270

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

35PCJ1L2270

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.

25PCJ2L1300

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.

15PCJ2L2360

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.

Frequently Asked Questions

What conductor sizes does this joint support?

This joint supports solid copper conductors sized at AWG 750.

What is the range of cable insulation diameters this joint accommodates?

The joint accommodates cable insulation diameters from 1.370 to 1.630 inches.

What is the maximum operating voltage for this joint?

The joint is rated for 15kV maximum operating voltage.

What type of housing does this joint use?

This joint features a single-piece housing for simplified installation.

Is this joint compatible with stranded copper conductors?

The joint is designed for solid copper conductors only.

How to Install the Single Core Joint (15PCJ1M2360)

This guide provides step-by-step instructions for installing the 15PCJ1M2360 Single Core Joint. It covers cable preparation, connector installation, and final jacket restoration for a permanent, submersible connection.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Wire brush, Cleaning cloth, Soldering iron, Sandpaper, Heat gun

Supplies needed:

Single Core Joint Housing, Compression connectors (copper or aluminum), PVC tape, Mastic tape, Heat shrink, Flat copper braid, Cleaning solvent, Lubricant, Constant force spring (optional)

  1. Prepare for Installation and Ensure Safety

    De-energize all apparatus in the work area before beginning any work. Train the cables into their final position, ensuring approximately 5mm between the cable ends. Store the heat shrink sleeve on one of the cables. Inspect all parts for damage, correct rating, and compatibility with mating parts before proceeding. Failure to follow safety instructions will result in serious or fatal injury.

  2. Remove Cable Jacket and Metallic Shield

    Remove the outer jackets of both cables to the specified dimension 'A' (e.g., 405mm for Size H, J, K). Carefully remove the cable's metallic tape screen for the distance 'B' (e.g., 125mm for Size H, J, K) and secure the ends with PVC tape, ensuring not to overlap onto the non-metallic screen.

  3. Prepare Non-Metallic Screen and Insulation

    Carefully remove the cable's non-metallic screen from both cables to dimension 'D' (e.g., 45mm for Size H, J, K). Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' (e.g., 150mm for Size H, J, K) from the end of both cables, but do not remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B'. WARNING: Do not nick, cut, or damage the insulation surface or conductor strands.

  4. Temporarily Store Joint Housing

    Apply one layer of PVC tape (half-lapped) over the metallic screen of Cable 1, starting at the jacket and extending 10mm beyond the metallic screen end. Install a different color PVC tape marker on Cable 1 to dimension 'B'. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, non-metallic screen, and the PVC-taped portion of the metallic tape screen on Cable 1. Store the joint housing onto Cable 1 up to the jacket. WARNING: Cover any sharp edges of the metallic screen with PVC tape to prevent damage to the joint housing.

  5. Remove Insulation and Crimp Conductor Splice

    Remove the cable insulation from both cables to dimension 'E'. Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring they are fully seated. Do not crimp yet. Verify the distance between insulations is within the 'Before' specification (e.g., 102mm for Size H, J, K). Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs and clean metal chips or filings from the splice joint assembly area. Wipe off all excess inhibitor and verify the distance between insulations is within the 'After' specification (e.g., 108mm for Size H, J, K). WARNING: Do not cut or nick the cable insulation or conductor.

  6. Clean and Lubricate Cable Core

    Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth. Always wipe towards the screen end to avoid contamination. Lubricate the cable insulation surfaces using the supplied lubricant, always wiping toward the screen end to provide a build-up or ramp of lubricant at the edge of the non-metallic screen. WARNING: Remove all contaminants from the surface of the insulation.

  7. Position and Install Joint Housing

    Slide the joint housing over the crimp connector into its final position. Measure the distance 'X' between the joint housing and the PVC tape markers on both sides, ensuring that 'X' is equal on each side of the joint housing. Remove the PVC tape applied in Step C to expose 25mm of copper tape.

  8. Restore Metallic Screen

    Wrap flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by soldering or by using a constant force spring to ensure a secure connection.

  9. Restore Outer Jacket

    Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink sleeve from Cable 1 over the center of the assembly and shrink it, starting at the center and working towards the ends. WARNING: Do not burn cables during the heating process.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.