Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1K1300 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.

ABB Installation Products 15PCJ1K1300 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786626526


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB 15PCJ1K1300 Style 1 power cable joint for 15kV aluminum conductors. Single-piece housing, suitable for cable insulation diameters 0.640" to 2.120". Accommodates AWG 350 stranded conductor. Meets IEEE Standard 404 (Latest Revision). Impulse Withstand: 110kV BIL. AC Withstand: 35kV. DC Withstand (manufacture): 70kV. DC Withstand (installation): 56kV. Corona Extinction @ 3pC: 13kV AC. Continuous current rating: Cable rating. Short-time current rating: Up to 35kA (cable rating). Shield design: IEEE Standard 592 (Latest Revision). Cyclic Aging: 30 days at 26.1kV AC continuous, 8 hrs/day load current, 130°F conductor temp. Connectors: ANSI C119.4 Class A and Class 3. Molded conductive shield for deadfront construction. Fully shielded, submersible molded rubber housing. Molded conductive insert prevents electrical stress on entrapped air. Grounding eye for ground wire connection. Cable entrance engages insulation shielding, no taping required. SKU: 15PCJ1K1300.
  • 15kV Voltage Class, meets IEEE Standard 404
  • Suitable for cable insulation diameters from 1.090" to 1.310"
  • Designed for AWG 350 stranded aluminum conductors
  • Fully shielded, fully submersible molded rubber housing
  • Provides a permanent, fully shielded, fully submersible straight splice

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
350 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.2500 L
Package Weight (Metric)
1.4740 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 350.

15PCJ1G2300

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 350.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750.

35PCJ1N2380

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 350.

15PCJ1J2300

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 350.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 250.

35PCJ1L2280

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1H1240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

35PCJ1J1240-1230

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. CTN.

25PCJ1H (CTN)

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. CTN.
35kV Power Cable Joint, Cable Insulation Diameter 1.370 inch to 1.630 inch.

35PCJ-M

35kV Power Cable Joint, Cable Insulation Diameter 1.370 inch to 1.630 inch.

Frequently Asked Questions

What is the voltage rating of this cable joint?

The ABB 15PCJ1K1300 power cable joint has a voltage rating of 15 kV.

What cable insulation diameter is this joint designed for?

This joint is designed for cable insulation diameters ranging from 1.090 inches to 1.310 inches.

What type of conductor material is this joint compatible with?

This joint is designed for use with aluminum conductors.

What is the conductor size for this ABB cable joint?

The joint is designed for AWG 350 stranded aluminum conductors.

What is the housing style of this power cable joint?

This is a Style 1 power cable joint with a single-piece housing.

How to Install the 15PCJ1K1300 Single Core Joint

Installation guide for the 15PCJ1K1300 single core joint for extruded solid dielectric cables.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, PVC tape, Cleaning solvent, Clean cloth, Lubricant, Soldering iron or constant force spring tool, Heat gun

Supplies needed:

Joint Housing, Conductor splice, Flat copper braid, Mastic tape, Heat shrink tubing

  1. Prepare the Cables

    Train cables into position and square cut. Remove jackets to specified dimensions. Carefully remove metallic screen and secure ends with PVC tape. Remove non-metallic screen, bevel Cable 1, and cut insulation to 'E' dimension without removing it. Install PVC tape marker on Cable 2 to dimension 'B'.

  2. Prepare and Store the Joint Housing

    Apply PVC tape over the metallic screen. Install a different color PVC tape marker on Cable 1 to dimension 'B'. Lubricate both cable entrances of the splice housing. Clean and lubricate Cable 1 insulation, non-metallic screen, and PVC taped portion. Store the housing onto Cable 1 up to the jacket, ensuring the metallic screen is covered with PVC tape to prevent housing damage.

  3. Remove Cable Insulation and Install Connector

    Remove cable insulation from both cables without nicking. Wire brush exposed conductors. Insert conductors into the conductor splice, ensuring they are fully seated. Crimp the conductor splice according to the provided chart. Remove any sharp protrusions or burrs and clean the area. Wipe off excess inhibitor.

  4. Clean and Lubricate Core Surfaces

    Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth, wiping towards the screen end. Lubricate cable insulation surfaces using the supplied lubricant, wiping towards the screen end to create a ramp.

  5. Install the Joint Housing

    Slide the joint housing over the crimp connector into its final position. Ensure the distance 'X' between the joint housing and the PVC tape marker is equal on each side. Remove PVC tape to expose 25mm of copper tape.

  6. Restore Screen and Outer Jacket

    Wrap flat copper braid around each joint housing, overlapping onto the metallic tape screen by 20mm on each side. Attach the braid ends to the metallic tape screen by soldering or using a constant force spring. Lightly sand the outer surface of the jacket on both cables for 130mm and heat for 15 seconds. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it from the center outwards.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.