ABB Installation Products 15PCJ1H1230 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786341795
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Fully shielded, fully submersible straight splice for 15kV applications
- Accommodates 0.850–1.050" cable insulation diameters
- Supports AWG stranded #1 or solid 1/0 aluminum conductors
- Molded conductive shield with grounding eye for deadfront construction
- Pin-and-socket interlock withstands up to 500 lbs of pull force
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | #1 STR AWG , 1/0 SOL AWG |
Connection | Compression |
Insulation | Yes |
Material | Aluminum |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | 15PCJ1H |
Size | 14-3/8 inch long |
Size | 0.850 inch to 1.050 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.7500 L |
Package Weight (Metric) | 0.7940 kg |

15PCJ1F2230
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
25PCJ1H1260
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
25PCJ1J2240
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25PCJ1K2300
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 350.
115TCJN46252P6QDDNB
115kV, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 6 - Bore Diameter 2.850 inch, Insulation Range 3.249-3.620 inch, Connector Type - Copper, Conductor Code 52P - 1.563-1.605 inch Diameter, Heatsink Size 6 - 3.250 inch Outside Diameter, Heatsink Bore Diameter Q - 1.625 inch, Type Shield D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit D - 4/0 Bonding Cable 6 foot long quantity 3 with Split Bolts quantity 12, Armour Kit - Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.
35PCJ1L1250
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15PCJ2J1230-G1230
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15PCJ1J1240
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.Frequently Asked Questions
What voltage classes are available?
The PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What standards do the joints meet?
The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404.
What is the phase-to-ground voltage for 35 kV class?
For the 35 kV class, the phase-to-ground voltage is 20.2 kV.
What is the purpose of Style 2 joints?
Style 2 PCJ power cable joints include separate cable adapters to allow for transition splicing between two different cable sizes.
What is the purpose of Style 1 joints?
Style 1 PCJ power cable joints are designed for straight splicing of two similar cables.
What is the housing material?
The power cable joints feature permanently crimped connectors inside ethylene propylene diene monomer (EPDM) rubber housings.
What is the maximum pull force resistance?
The pin-and-socket interlock design of the PCJ power cable joints can withstand a pull force up to 500 lb.
What is the short-time current rating?
The short-time current rating is equal to that of the cable rating, up to 35 kA.
What is the continuous current rating?
The continuous current rating of the PCJ power cable joint is equal to that of the cable rating.
What is the maximum conductor size?
The PCJ power cable joints can be used with conductors up to 1250 kcmil.
How to Install the 15PCJ1H1230 Single Core Joint
This guide provides step-by-step instructions for the permanent installation of a fully screened, submersible single core joint for extruded solid dielectric cables, ensuring proper preparation, connection, and restoration.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Utility knife, Measuring tape or ruler, Wire brush, Crimping tool, Sandpaper, Heat gun, Soldering iron (optional, if not using constant force spring)
Supplies needed:
Joint Housing, PVC tape, Conductor splice (copper or aluminum compression connector), Cleaning solvent, Clean cloth, Lubricant, Flat copper braid, Constant force spring (optional, if not soldering), Mastic tape, Heat shrink
- Prepare Cables and Remove Jacket/Metallic Shield
DANGER: Ensure all apparatus is de-energized during installation. Train both cables into their final position and square cut them, leaving approximately 5mm between the cable ends. Store the heat shrink supplied with the kit onto either cable. Remove the outer jackets of both cables to the dimensions specified in the 'STEP A' table (e.g., 405mm for Size H, J, K). Carefully remove the cable metallic tape screen for the distance shown in the table and secure the ends with PVC tape. Ensure the PVC tape is only on the copper tape and does not overlap onto the non-metallic screen.
- Remove Non-Metallic Screen and Prepare Insulation
WARNING: Do not nick, cut, or damage the insulation surface or conductor strands. Carefully remove the cable non-metallic screen (semi-conductive shield) from both cables to the point specified in the 'STEP B' table (e.g., 45mm for Size H, J, K). Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' (e.g., 150mm for Size H, J, K) from the end of both cables, but DO NOT remove the insulation at this stage. Install a PVC tape marker on Cable 2 to dimension 'B' (e.g., 155mm for Size H, J, K) to locate the splice later.
- Temporarily Store Joint Housing and Prepare Cable 1
WARNING: The forward edge and any other sharp edges of the metallic screen must be covered with PVC tape to prevent damage to the joint housing. Beginning at the jacket and extending 10mm beyond the end of the metallic screen, apply one layer (half-lapped) of PVC tape over the metallic screen on Cable 1. Install a different color PVC tape marker on Cable 1 to dimension 'B' (e.g., 155mm for Size H, J, K) to locate the splice later. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and the PVC taped portion of the cable metallic tape screen on Cable 1. Store the joint housing onto Cable 1 up to the jacket; DO NOT store the splice housing on the exposed metallic tape shield.
- Remove Cable Insulation and Install Connector
Remove the cable insulation from both cables to expose the conductor. DO NOT cut or nick the cable insulation or conductor. Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring both conductors are fully seated. DO NOT CRIMP yet. Check the distance between the insulations; if it exceeds the 'Check Dim (Before)' in the 'STEP E' table (e.g., 108mm for Size H, J, K), review instructions and redo. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs and ensure all metal chips or filings are removed from the splice joint assembly area. Wipe off any excess inhibitor. Check the distance between cable insulations again; if it exceeds the 'Check Dim (After)' in the 'STEP E' table (e.g., 133mm for Size H, J, K), review instructions and redo.
- Clean and Lubricate Core
WARNING: Remove all contaminants from the surface of the insulation. Clean the conductor, connector, and Cable 2 insulation surfaces thoroughly with cleaning solvent and a clean cloth. Always wipe towards the screen end. Lubricate the cable insulation surfaces using the supplied lubricant. Always wipe toward the screen end to provide a build-up or ramp of lubricant at the edge of the non-metallic screen.
- Position Joint Housing
Slide the joint housing over the crimp connector into its final position. Measure the distance between the joint housing and the PVC tape marker on both sides. The distance 'X' should be equal on each side of the joint housing. Remove the PVC tape applied in Step C to expose 25mm of copper tape on each side.
- Restore Screen
Wrap flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by soldering or by using a constant force spring.
- Restore Outer Jacket
Lightly sand the outer surface of the jacket of both cables for a distance of 130mm from the joint housing. Heat both sanded areas for approximately 15 seconds; DO NOT BURN CABLES. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it, starting at the center and working toward the ends.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.