Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1L1250 - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

ABB Installation Products 35PCJ1L1250 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786350988


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35PCJ1L1250 is a 35kV power cable joint designed for medium-voltage cable systems requiring permanent, fully shielded, and fully submersible straight splices. This joint features a single-piece molded rubber housing for simplified installation and consistent performance, accommodating cable insulation diameters from 1.180 inch to 1.465 inch. The aluminum conductor supports stranded 2/0 AWG or solid 3/0 AWG configurations, providing flexibility for different load requirements. Rated per IEEE Standard 404 for 35kV voltage class, the 35PCJ1L1250 delivers a 200kV BIL impulse withstand (1.2 x 50 microsecond wave), 69kV AC withstand, and 30kV AC corona extinction at 3pC sensitivity. The continuous current rating matches the cable rating, with a short-time current rating up to 35kA. The molded conductive shield ensures a virtually indestructible ground shield for true deadfront construction, while the grounding eye provides a convenient point for ground wire connection. This joint is engineered for use in industrial, utility, and commercial power distribution systems, including substations, industrial plants, renewable energy installations, and underground cable systems. It withstands pulls of up to 500 lbs and is suitable for direct burial or vault installations. The pin and socket interlock design ensures electrical and water seal integrity, making it ideal for new installations or repairs to broken cables. The shield design meets IEEE Standard 592, and connectors comply with ANSI C119.4 Class A and Class 3 ratings. Typical applications include joining cable runs in medium-voltage systems or repairing damaged cables in existing installations. The single-piece housing reduces assembly time and minimizes installation errors, while the robust construction ensures mechanical strength and environmental resistance.
  • Single-piece molded rubber housing for simplified installation
  • Accommodates cable insulation diameters from 1.180" to 1.465"
  • Aluminum conductor supports stranded 2/0 AWG or solid 3/0 AWG
  • Rated per IEEE Standard 404 for 35kV voltage class
  • Fully shielded, fully submersible, withstands pulls up to 500 lbs

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
2/0 STR AWG , 3/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
35PCJ1L
Size
14-3/8 inch long
Size
Cable Insulation Diameter 1.180 inch to 1.465 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.2500 L
Package Weight (Metric)
1.4740 kg
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

35PCJ2L2250

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ2J1230-G1230

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1J1240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.

15PCJ1H1280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1Q242PNDNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. With Customer Specific Modifications

15PCJ2J127P-G125P

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. With Customer Specific Modifications
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

25PCJ1J1260

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 750.

15PCJ2L1360

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 750.

Frequently Asked Questions

What material are PCJ cable joints made from?

Elastimold PCJ power cable joints feature permanently crimped connectors inside EPDM rubber housings.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 allows for transition splicing between different cable sizes.

What type of connector is included in the N1 kit?

The N1 kit includes an aluminum compression connector suitable for splicing aluminum to aluminum or aluminum to copper conductors.

What is the short-time current rating for PCJ joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating for PCJ joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What safety standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings.

Is taping required for PCJ joint cable entrances?

No, the cable entrance engages the insulation shielding of the cable, eliminating the need for taping.

What conductor materials are compatible with PCJ joints?

PCJ power cable joints are compatible with both copper and aluminum conductors.

What voltage classes are available for PCJ joints?

PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

Where can PCJ power cable joints be installed?

PCJ power cable joints can be installed in direct-burial, underground vault, and overhead applications.

How to Install the 15/25/35PCJ1 Straight Joint

This guide provides step-by-step instructions for the safe and proper installation of the 15/25/35PCJ1 straight joint for wire shielded cables, designed for permanent, fully shielded, and submersible applications.

Estimated time: 1h 30m

Tools needed:

Cable stripping tools, Wire brush, Crimping tool, T&B WT3D tool (for 35kV only)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding wires), DELTECt Cable ties (for 35kV only), #14 AWG copper wire (or equivalent, if needed), Cable jacket repair material (if applicable)

  1. Ensure Safety and Prepare Workspace

    De-energize all apparatus in the work area. Inspect package contents and all components for damage, proper rating, and compatibility. Gather all required tools and maintain cleanliness throughout the procedure. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Prepare Cables for Jointing

    Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires and cut both cables at the joint centerline.

  3. Prepare Cable 1 and Position Joint Housing

    Taper the edge of Cable 1 insulation from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1 up to the shield wires.

  4. Prepare Cables for Splice

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2 according to the specified dimensions ("X" and "Y" from the table). Ensure not to cut or nick the cable insulation or conductor during this process.

  5. Install and Crimp the Splice

    If conductors are aluminum, wire-brush them immediately before insertion into the splice. Insert conductors into the splice and crimp it according to the splice manufacturer's recommendations. Wipe off any excess inhibitor. Verify the distance between cable insulations against the "Max Check After" dimension in the table; redo assembly if it exceeds. Remove any sharp protrusions or burrs from the crimped splice and clean the splice and joint assembly area. Clean and lubricate the cables where indicated, building up lubricant at the edge of the insulation shield.

  6. Finalize Joint Assembly and Grounding

    Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations only, install two DELTECt Cable ties on each end of the cable entrance as specified, using a T&B WT3D tool if available, and remove the yellow pin from the joint grounding eye. Retrain shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, repeating for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket over both cables and the joint housing where applicable.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.