ABB - Installation Products 25PCJ1J2240 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

ABB Installation Products 25PCJ1J2240 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786343034


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 25kV Power Cable Joint (SKU: 25PCJ1J2240) is a single-piece housing joint designed for medium-voltage power cable systems rated at 25kV. This joint accommodates cable insulation diameters between 0.980 inch and 1.180 inch, making it suitable for 1/0 AWG stranded or 2/0 AWG solid copper conductors. The single-piece housing simplifies installation by eliminating multiple assembly steps, reducing labor time and potential error points compared to traditional multi-piece designs. This joint is part of ABB’s medium-voltage cable accessory portfolio, which is widely used in utility, industrial, and commercial power distribution networks where reliable, long-term cable connections are required. The joint’s construction ensures consistent dielectric performance and mechanical integrity, meeting industry standards for 25kV class applications. It is intended for use in environments where medium-voltage power cables require splicing or termination, such as substations, switchgear, and underground distribution systems. The copper conductor compatibility supports high current carrying capacity, ensuring minimal voltage drop in power transmission applications. This product is not rated for direct burial without additional protective measures as per installation guidelines.
  • Rated for 25kV medium-voltage power cable systems
  • Single-piece housing simplifies installation and reduces assembly errors
  • Accommodates cable insulation diameters from 0.980" to 1.180"
  • Compatible with 1/0 AWG stranded or 2/0 AWG solid copper conductors
  • Designed for utility, industrial, and commercial power distribution networks

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
1/0 STR AWG , 2/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.0000 L
Package Weight (Metric)
0.9070 kg
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ2J1240-H1240

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 350.

25PCJ1K2300

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 350.
115kV, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 6 - Bore Diameter 2.850 inch, Insulation Range 3.249-3.620 inch, Connector Type - Copper, Conductor Code 52P - 1.563-1.605 inch Diameter, Heatsink Size 6 - 3.250 inch Outside Diameter, Heatsink Bore Diameter Q - 1.625 inch, Type Shield D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit D - 4/0 Bonding Cable 6 foot long quantity 3 with Split Bolts quantity 12, Armour Kit - Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

115TCJN46252P6QDDNB

115kV, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 6 - Bore Diameter 2.850 inch, Insulation Range 3.249-3.620 inch, Connector Type - Copper, Conductor Code 52P - 1.563-1.605 inch Diameter, Heatsink Size 6 - 3.250 inch Outside Diameter, Heatsink Bore Diameter Q - 1.625 inch, Type Shield D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit D - 4/0 Bonding Cable 6 foot long quantity 3 with Split Bolts quantity 12, Armour Kit - Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

35PCJ1L1250

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ2J1230-G1230

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1J1240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.

15PCJ1H1280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1Q242PNDNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

Frequently Asked Questions

What are the available voltage classes for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What is the BIL impulse withstand for a 25 kV class joint?

For a 25 kV class joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 150 kV.

What is the overall length of a 25PCJ1GX joint?

The overall length (Dimension A) for a 25PCJ1GX joint is 14 3/8 inches.

Can copper connectors be used on aluminum conductors?

No, copper compression connectors are suitable for splicing copper conductors to copper conductors only and should not be used on aluminum conductors.

What type of connector is included for aluminum conductors?

The kit includes an aluminum compression connector suitable for splicing aluminum-to-aluminum or aluminum-to-copper conductors.

What is the corona extinction voltage for a 35 kV class joint?

The corona extinction voltage with 3 pC sensitivity for a 35 kV class joint is 30 kV.

What standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404.

What installation environments are suitable for PCJ joints?

PCJ power cable joints provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables, while Style 2 uses separate cable adapters for transition splicing between different cable sizes.

What types of conductors are compatible with PCJ joints?

PCJ power cable joints can be used with both copper and aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.

How to Install the 15/25/35PCJ1 Cable Joint

This guide provides step-by-step instructions for installing the 15/25/35PCJ1 series straight joint, a permanent, fully shielded, and submersible joint for connecting aluminum to aluminum or aluminum to copper wire shielded cables.

Estimated time: 2h 30m

Tools needed:

Wire-brush, Crimping tool, T&B WT3D tool (for 35kV only), Wire strippers

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Connector (user supplied), DELTECt Cable ties (for 35kV ONLY), #14 AWG copper wire (or equivalent)

  1. De-energize and Inspect Components

    DANGER: Ensure all apparatus is de-energized before beginning installation. Inspect all parts for damage, proper rating, and compatibility with mating components. Verify package contents are complete and undamaged.

  2. Gather Tools and Maintain Cleanliness

    Have all required tools readily available and maintain a clean work area throughout the entire installation procedure to prevent contamination.

  3. Prepare Cable Lengths and Jackets

    Overlap both cables and cut them to 12 inches (305mm) from the joint's centerline. Remove the cable jacket from Cable 1 to 37 inches (940mm) and from Cable 2 to 21 inches (530mm). Fold back the shield wires and then cut both cables at the joint's centerline.

  4. Taper Cable 1 and Lubricate

    Taper the edge of Cable 1's insulation shield from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends.

  5. Store Joint Housing on Cable 1

    Slide the joint housing onto Cable 1, pushing it up to the folded-back shield wires. This procedure is designed to prevent contamination of electrical interfaces.

  6. Remove Cable Insulation and Shield

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2, according to the 'X' and 'Y' dimensions provided in the documentation for your specific conductor size. WARNING: Do not cut or nick the cable insulation or conductor during this process.

  7. Install and Crimp Splice

    If conductors are aluminum, wire-brush them immediately before insertion into the splice. Insert conductors into the splice and crimp it according to the manufacturer's recommendations. Verify the dimension between cable insulations against the 'Max Check Before' and 'Max Check After' tables in the documentation, redoing the assembly if it exceeds the maximum.

  8. Clean and Lubricate Splice Area

    Wipe off any excess inhibitor from the splice. Remove any sharp protrusions or burrs generated during crimping, ensuring all metal chips and filings are cleared from the splice and joint assembly area. Clean the cables where indicated and lubricate them in the direction of the arrows to create a ramp of lubricant at the edge of the insulation shield.

  9. Position Joint Housing

    Slide the joint housing into its final position. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.

  10. Install Cable Ties and Remove Grounding Pin (35kV Only)

    For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance. Position the outer ties approximately 1/4 inch (6mm) from the splice edge, and the second ties approximately 1/4 inch (6mm) from the first, with an offset of the locking heads. Use a T&B WT3D tool to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye.

  11. Secure Shield Wires and Grounding

    Retrain the shield wires and secure them to the ends of the joint as shown in the diagrams. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector.

  12. Reconstruct Cable Jacket

    Where applicable, reconstruct the cable jacket over both cables and the joint housing to complete the installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.