Authorized ABB Distributor (Installation Products)
ABB - Installation Products 115TCJN46252P6QDDNB - 115kV, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 6 - Bore Diameter 2.850 inch, Insulation Range 3.249-3.620 inch, Connector Type - Copper, Conductor Code 52P - 1.563-1.605 inch Diameter, Heatsink Size 6 - 3.250 inch Outside Diameter, Heatsink Bore Diameter Q - 1.625 inch, Type Shield D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit D - 4/0 Bonding Cable 6 foot long quantity 3 with Split Bolts quantity 12, Armour Kit - Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

ABB Installation Products 115TCJN46252P6QDDNB 115kV, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4…

UPC: 783786348473


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 115kV Transmission Cable Joint, SKU 115TCJN46252P6QDDNB, is engineered for reliable power transmission infrastructure. Designed with a non-shieldbreak housing type and Housing Style 4, it features Housing Size 6 with a 2.850-inch bore diameter. The insulation range accommodates conductors from 3.249 to 3.620 inches, ensuring a secure fit for a variety of cable types. The connector is constructed from high-grade copper, providing excellent conductivity and durability. This joint is specifically designed for Conductor Code 52P, which corresponds to a conductor diameter range of 1.563 to 1.605 inches. The integrated heatsink, Size 6 with a 3.250-inch outside diameter and a 1.625-inch bore diameter, aids in thermal management. The metallic screen continuity is achieved through Type Shield D, utilizing copper tape and neutral wire, and includes a Metallic Screen Continuity Kit D. This kit comprises three 6-foot lengths of 4/0 bonding cable and twelve split bolts for secure connections. An Outer Jacket Restoration Kit B, featuring standard heat shrink, is included for complete installation. The Armour Kit is not required for this configuration. This transmission cable joint is suitable for 115 kV applications where robust and dependable connections are paramount.
  • 115 kV Voltage Rating for high-power transmission.
  • Copper Connector ensures superior electrical conductivity.
  • Housing Size 6 with 2.850-inch Bore Diameter for precise cable fit.
  • Insulation Range: 3.249-3.620 inches.
  • Includes Metallic Screen Continuity Kit D with 4/0 bonding cable and split bolts.

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Conductor Range
1.563 to 1.605 in
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Non-Shieldbreak
Voltage Rating
115 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
115 kV, TCJ - Transmission Cable Joint, Housing Type N - Non-Shieldbreak, Housing Style 4 - 57.2mm to 91.96mm (2.25 inch to 3.62 inch)

115TCJN4-DP0592567

115 kV, TCJ - Transmission Cable Joint, Housing Type N - Non-Shieldbreak, Housing Style 4 - 57.2mm to 91.96mm (2.25 inch to 3.62 inch)
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

35PCJ1L1250

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ2J1230-G1230

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1J1240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.

15PCJ1H1280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1Q242PNDNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. With Customer Specific Modifications

15PCJ2J127P-G125P

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. With Customer Specific Modifications
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

25PCJ1J1260

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

Frequently Asked Questions

What is the voltage class of TCJ cable joints?

TCJ transmission cable joints are designed for 46 kV through 138 kV class systems.

What is the maximum system voltage for 69 kV class joints?

The maximum system voltage for 69 kV class joints is 72.5 kV.

What type of connectors are compatible for joining conductors?

Conductors can be joined using a compression, welded, or other type of connector.

What standards do TCJ joints meet for type tests?

TCJ transmission cable joints meet type test standards per IEC 60840/IEEE 404.

What is the maximum continuous conductor temperature?

The maximum continuous conductor temperature for TCJ joints is 90 °C.

What is the continuous current rating for TCJ joints?

The continuous current rating for TCJ transmission cable joints is equal to the cable's rating.

What is the maximum system voltage for 138 kV class joints?

The maximum system voltage for 138 kV class joints is 145 kV.

What materials are used in TCJ joint housing?

The void-free joint housing consists of peroxide-cured EPDM insulation bonded under pressure to peroxide-cured molded semi-conductive elements.

Do TCJ joints require field molding or tape?

No, TCJ joints do not require field molds, wrapping machines, or pre-stretch, simplifying field assembly.

What are the typical applications for TCJ cable joints?

TCJ cable joints provide permanent, fully shielded, fully submersible cable joints for direct-burial or vault applications.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.