Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1G2240 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

ABB Installation Products 15PCJ1G2240 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786339600


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 30

Multiplier: 30

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 15kV Power Cable Joint, SKU 15PCJ1G2240, is designed for reliable electrical connections in medium-voltage applications. It features a single-piece housing for simplified installation and robust protection. The joint is engineered to accommodate cable insulation diameters ranging from 0.760 inches to 0.950 inches, ensuring compatibility with a specific range of power cables. It is suitable for use with copper conductors, supporting both stranded 1/0 AWG and solid 2/0 AWG conductor sizes. This product is part of ABB's Installation Products catalog, known for its commitment to electrical infrastructure solutions. The UNSPSC code for this item is 39121452, categorizing it within electrical connectors and accessories. The single-piece housing design streamlines the jointing process, reducing potential points of failure and installation time. This joint is a critical component for maintaining the integrity and safety of medium-voltage power distribution systems where precise and durable connections are paramount. Its specifications are tailored for electrical contractors and utility professionals requiring dependable cable termination solutions for specific conductor and insulation sizes.
  • 15kV voltage rating for medium-voltage power distribution
  • Single-piece housing for simplified installation
  • Accommodates cable insulation diameters from 0.760" to 0.950"
  • Designed for copper conductors, 1/0 AWG stranded / 2/0 AWG solid
  • ABB Installation Products quality and reliability

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
1/0 STR AWG , 2/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.9300 L
Package Weight (Metric)
0.4220 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1F2240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ1G2230

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ1H1230

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

25PCJ1H1260

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ1J2240

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 350.

25PCJ1K2300

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 350.
115kV, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 6 - Bore Diameter 2.850 inch, Insulation Range 3.249-3.620 inch, Connector Type - Copper, Conductor Code 52P - 1.563-1.605 inch Diameter, Heatsink Size 6 - 3.250 inch Outside Diameter, Heatsink Bore Diameter Q - 1.625 inch, Type Shield D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit D - 4/0 Bonding Cable 6 foot long quantity 3 with Split Bolts quantity 12, Armour Kit - Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

115TCJN46252P6QDDNB

115kV, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 6 - Bore Diameter 2.850 inch, Insulation Range 3.249-3.620 inch, Connector Type - Copper, Conductor Code 52P - 1.563-1.605 inch Diameter, Heatsink Size 6 - 3.250 inch Outside Diameter, Heatsink Bore Diameter Q - 1.625 inch, Type Shield D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit D - 4/0 Bonding Cable 6 foot long quantity 3 with Split Bolts quantity 12, Armour Kit - Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

35PCJ1L1250

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

Frequently Asked Questions

What is the AC withstand voltage for a 25 kV class joint?

For a 25 kV class joint, the AC withstand at 60 Hz for 1 minute is 52 kV.

What type of connector is included in an aluminum compression kit?

A kit with an aluminum compression connector is suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.

How does the cable entrance simplify installation?

The cable entrance engages the insulation shielding of the cable, which eliminates the need for taping during installation.

What is the maximum pull force the interlock can withstand?

The pin-and-socket interlock is designed to withstand a pull force of up to 500 lb.

What is the largest cable insulation diameter for 15PCJ-1?

The largest cable insulation diameter supported by 15PCJ-1 is 2.120 inches, corresponding to symbol Q.

What voltage classes are available for PCJ joints?

PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What is the short-time current rating of PCJ joints?

The short-time current rating is equal to that of the cable rating, up to 35 kA.

What is the BIL impulse withstand for a 15 kV class joint?

For a 15 kV class joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 110 kV.

What is the continuous current rating of PCJ joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are for copper-to-copper connections only and should not be used on aluminum conductors.

How to Install the 15PCJ1G2240 Single Core Cable Joint

This guide provides detailed instructions for installing the 15PCJ1G2240 single core cable joint, creating a permanent, fully screened, and submersible connection for XLPE or EPR cables. Installation should only be performed by competent personnel trained in high voltage electrical equipment safety practices.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Measuring tape or ruler, Wire brush, Crimping tool, Cleaning solvent, Clean cloth, Soldering iron (or tool for constant force springs), Sandpaper, Heat gun

Supplies needed:

Joint Housing, Conductor Splice (compression connector), PVC Tape (various colors for marking), Lubricant (supplied with kit), Flat Copper Braid, Constant Force Springs (if not soldering), Mastic Tape, Heat Shrink

  1. Prepare Cables: Remove Jacket and Metallic Shield

    De-energize all apparatus. Train cables into final position, leaving approximately 5mm between them. Store the heat shrink on either cable. Remove cable jackets to dimensions A (405-635mm) and metallic tape screen to dimensions B (125-190mm). Secure metallic screen ends with PVC tape, ensuring no overlap onto the non-metallic screen. Refer to the provided table for exact dimensions based on cable size.

  2. Prepare Cables: Remove Non-Metallic Screen and Bevel Insulation

    Carefully remove the cable non-metallic screen from both cables to dimension D (45-70mm). Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension E (150-165mm) from the end of both cables, but DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension B (155-230mm) to locate the splice later. WARNING: Do not nick, cut, or damage the insulation surface or conductor strands.

  3. Temporarily Store Joint Housing and Apply PVC Tape

    Apply one layer (half-lapped) of PVC tape over the metallic screen on Cable 1, starting at the jacket and extending 10mm beyond the metallic screen end. Install a different color PVC tape marker on Cable 1 to dimension B (155-230mm). Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, non-metallic screen, and PVC-taped metallic screen portion of Cable 1. Store the housing onto Cable 1 up to the jacket. WARNING: Cover all sharp edges of the metallic screen with PVC tape to prevent damage to the joint housing.

  4. Remove Cable Insulation

    Carefully remove the cable insulation from both cables to dimension E (45-70mm) from the end. Ensure you DO NOT cut or nick the cable insulation or conductor during this process.

  5. Install Conductor Splice

    Wire brush the exposed conductors of both cables. Immediately insert both conductors fully into the conductor splice. Check the distance between insulations; if it exceeds the 'Before' dimension (108-170mm), do not proceed and re-evaluate. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs. Wipe off excess inhibitor. Verify the distance between cable insulations again; if it exceeds the 'After' dimension (102-165mm), do not proceed and re-evaluate.

  6. Clean and Lubricate Core Surfaces

    Clean the conductor, connector, and Cable 2 insulation surfaces using cleaning solvent and a clean cloth. Always wipe towards the screen end. Lubricate cable insulation surfaces using the supplied lubricant, wiping towards the screen end to create a build-up or ramp of lubricant at the edge of the non-metallic screen. WARNING: Remove all contaminants from the surface of the insulation.

  7. Install Joint Housing

    Slide the joint housing over the crimp connector into its final position. Measure the distance 'X' between the joint housing and the PVC tape marker on each side; ensure these distances are equal. Remove the PVC tape applied in Step C to expose 25mm of copper tape on each side.

  8. Restore Screen

    Wrap flat copper braid around each joint housing, extending the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by soldering or by using a constant force spring.

  9. Restore Outer Jacket

    Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds, being careful not to burn the cables. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it, starting at the center and working towards the ends.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.