All Categories

Electrical Systems and Lighting and Components and Accessories and Supplies

Electrical Equipment, Components, and Supplies

Electrical Lugs Plugs And Connectors

Subcategories

    Automatic Wire Or Cable Connector

    Backshell connectors

    Battery Terminal

    Cable Gland Connector

    Cable Joint

    Cable Or Wire Lug

    Circular Connectors

    Coaxial Connectors

    Connecting Leads or Wires

    Connector And Cable Seal

    Crab Joint

    Electrical Connector Assembly

    Electrical Extension Cable

    Electrical Metallic Tubing Emt Connectors

    Electrical Metallic Tubing Emt Elbow

    Electrical plug/receptacle adapter

    Electrical Plugs

    Electrical Receptacles

    Electrical Sleeves

    Electrical Taps

    Electrical Terminals

    Electrical Underground Bus Connector

    Electronic Connector Caps

    Flex Connectors

    Flexible Braid

    Heavy Duty Connector Hood & Housing

    Heavy Duty Connector Insert & Contact

    Input Output Connector Cover

    Jack for Plug

    Jumper Bar

    Liquid Tight Connectors

    Locking Plug

    Mechanical Connector Lug and Cap

    Mechanical Connectors

    Panel Interface Connector

    Power Distribution Blocks

    Printed Circuit Board Pcb Press Fit Header Connector

    Rj Jack And Module

    Tap Off

    Telecommunication Connector

    Terminal Block Accessories

    Terminal Block Covers

    Terminal Block Markers and Marking Accessories

    Terminal Block Separator

    Terminal Blocks

    Terminal Strips

    Twist On Wire Connector

    Wire Connectors

    Wire Or Cable Compression Connector

    Wire Or Cable Compression Reducer

    Wire Or Cable Compression Splice

    Wire Terminal Connector Kit

    Wire Terminal Disconnect

    Wiring Taps

Showing 25-36 of 544 results

ABB - Installation Products 54635 - Copper Cable Joint, Wire Range Min: 6 #8 Str, Max: 2 #4 with 2 #8 Sol or Str, Tin Plated, Black Die
ABB - Installation Products · Color-Keyed

54635


Copper Cable Joint, Wire Range Min: 6 #8 Str, Max: 2 #4 with 2 #8 Sol or Str, Tin Plated, Black Die

Contact for Pricing

Minimum Qty: 100

Multiplier: 100

*Contact for lower quantities*

ABB - Installation Products PT66M - Nylon Insulated Crimp-On Wire Joint Connector, Length .50 Inches, Base Diameter .93 Inches, Wire Range 2-#18 to 3-#12, Steel, Tin Plated
ABB - Installation Products · Sta-Kon

PT66M


Nylon Insulated Crimp-On Wire Joint Connector, Length .50 Inches, Base Diameter .93 Inches, Wire Range 2-#18 to 3-#12, Steel, Tin Plated

Contact for Pricing

Minimum Qty: 100

Multiplier: 100

*Contact for lower quantities*

ABB - Installation Products PT80 - Non-Insulated Crimp-On Wire Joint, Length .62 Inches, Base Diameter .35 Inches, Wire Rage 2-#16 to 4-#10 Steel, Copper Plated
ABB - Installation Products · Sta-Kon

PT80


Non-Insulated Crimp-On Wire Joint, Length .62 Inches, Base Diameter .35 Inches, Wire Rage 2-#16 to 4-#10 Steel, Copper Plated

Contact for Pricing

Minimum Qty: 100

Multiplier: 100

*Contact for lower quantities*

ABB - Installation Products TN14-WJ-XV - Insulated Nylon Wire Joint for Wire Range 16-14 , White, Reusable Packaging
ABB - Installation Products · CATAMOUNT

TN14-WJ-XV


Insulated Nylon Wire Joint for Wire Range 16-14 , White, Reusable Packaging

Contact for Pricing

Minimum Qty: 75

Multiplier: 75

*Contact for lower quantities*

ABB - Installation Products 69TCJS44 - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4
ABB - Installation Products · ABB

69TCJS44


69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4

Contact for Pricing

ABB - Installation Products 69TCJS44B54P45SLNNB - 69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Copper/No Connector Required, Conductor Code 54P - 1.648-1.746 inch Diameter, Heatsink Size 4 - 2.500 inch Outside Diameter, Heatsink Bore Diameter S - 1.750 inch, Type Shield L - Lead and Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.
ABB - Installation Products · ABB

69TCJS44B54P45SLNNB


69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Copper/No Connector Required, Conductor Code 54P - 1.648-1.746 inch Diameter, Heatsink Size 4 - 2.500 inch Outside Diameter, Heatsink Bore Diameter S - 1.750 inch, Type Shield L - Lead and Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

Contact for Pricing

ABB - Installation Products 69TCJS1RA46PNNNNNN - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required
ABB - Installation Products · ABB

69TCJS1RA46PNNNNNN


69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required

Contact for Pricing

ABB - Installation Products 69TCJS1R242PNLNNB - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
ABB - Installation Products · ABB

69TCJS1R242PNLNNB


69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

Contact for Pricing

ABB - Installation Products 69TCJS1R140PVBNNB - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - V - 2.046 inch Diameter. Type Shield - B - Copper Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
ABB - Installation Products · ABB

69TCJS1R140PVBNNB


69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - V - 2.046 inch Diameter. Type Shield - B - Copper Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

Contact for Pricing

ABB - Installation Products 69TCJS1Q233PRCBNB - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 33P - Conductor Diameter Range - .781-.815 inch (19.84-30.70mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
ABB - Installation Products · ABB

69TCJS1Q233PRCBNB


69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 33P - Conductor Diameter Range - .781-.815 inch (19.84-30.70mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

Contact for Pricing

ABB - Installation Products 35PCJ1M - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch.
ABB - Installation Products · ABB

35PCJ1M


35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch.

Contact for Pricing

ABB - Installation Products 35PCJ1N1380-S - 35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Jacket Seal included.
ABB - Installation Products · ABB

35PCJ1N1380-S


35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Jacket Seal included.

Contact for Pricing

Showing 25-36 of 544 results