Contact for Pricing
Overview
- Five-micron airline filter, 115 V solenoid
- Thermostat
- Ducting kit
- Cooling capacities to 2500 BTU/Hr. (733 W)
- Energy-efficient (117W) with rapid installation and low operational costs
Specifications
Application | Controls and Drives;Power Distribution |
Application | Power Distribution; Controls and Drives |
Btu Rating | 900 |
Color | Unpainted |
Depth | 2 in |
Depth | 51 mm |
Finish | Brushed |
Frequency Rating | 50/60 Hz |
Frequency Rating, Maximum | 60 Hz |
Frequency Rating, Minimum | 50 Hz |
Height | 9.94 in |
Height | 252 mm |
Material | Aluminum |
Nominal Capacity Btu/h | 900 Btu/h |
Nominal Capacity Watts | 264 W |
Nominal Voltage | 115 V |
Product Family | Vortex |
Type | Vortex Coolers |
Voltage AC | 100-120 V |
Voltage Rating | 115 V |
Weight | 2.72 kg |
Weight | 5.5 lb |
Width | 51 mm |
Width | 2 IN |
Package Dimensions (L x W x H) | 12.9 IN x 9.5 IN x 4.4 IN |
Package Dimensions (L x W x H) | 32.766 cm x 24.13 cm x 11.176 cm |
Package Weight (Imperial) | 5.500 L |
Package Weight (Metric) | 2.495 kg |
How to Install the VCool System Model VC0916004
This guide provides step-by-step instructions for installing the VCool System Model VC0916004, ensuring proper setup and configuration for optimal cooling performance.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Locknut, Ducting kit, Cold air muffler, Compressed air filter, Solenoid valve, Thermostat
- Prepare the enclosure
Cut a 1-15/16” (49 mm) hole in the enclosure to accommodate the VCool unit.
- Mount the VCool unit
Insert the VCool into the cut-out and secure it with the locknut, ensuring it is oriented vertically with the silver cap facing up.
- Attach the cold air muffler
Connect the cold air muffler to the outlet of the VCool unit to direct the cooled air into the enclosure.
- Install the ducting kit
Perforate the ducting kit with several 1/8” holes and secure it to the interior of the enclosure, then attach it to the cold air muffler.
- Connect the compressed air components
Wire the compressed air filter, solenoid valve, and thermostat to the VCool unit, ensuring the thermostat is wired directly to the solenoid valve.
- Connect the compressed air supply
Attach the compressed air supply line to the filter, ensuring that the filter is installed in a location where the temperature does not exceed 125°F (52°C).
- Verify installation
Check all connections for leaks and ensure that the VCool unit is functioning properly before closing the enclosure.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.