Contact for Pricing
Overview
- 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
- Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
- Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
- Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
- Door bar system present on all doors (including window doors)
- Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
- 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
- Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
- Two grounding studs present on each door
- Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)
Specifications
Application | Controls and Drives; Power Distribution |
Color | Light Gray |
Color Code | RAL 7035 |
Depth | 31.69 |
Depth | 805 |
Door Quantity | 2 |
Finish | Powder Coated |
Height | 86.69 |
Height | 2,202 |
Material | Mild Steel |
Max Rack Mount Unit | 47 |
Max Subpanel Size | 82.9 x 36.5 in |
Max Subpanel Size | 2106 x 928 mm |
Product Family | ProLine |
Type | Mild Steel Modular Industrial Enclosures |
Weight | 398 lb |
Width | 39.67 |
Width | 1,008 |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackFrequently Asked Questions
What is the load rating of the ProLine G2 frame?
The ProLine G2 frame has a 15% higher load rating than the competition.
What is the maximum weight the subpanel can hold?
The subpanel can hold greater than 45% more weight than previous models.
What materials are used in the ProLine G2 frame?
The frame is made of 12 gauge (2.5 mm) roll-formed steel.
What is the weight capacity of the mobile base?
The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).
What are the available frame sizes for ProLine G2?
Frame heights range from 600 mm to 2200 mm, with various widths and depths.
How can I customize my ProLine G2 enclosure?
You can select from over 400 standard components and accessories to create a custom solution.
What safety features are included with ProLine G2?
Safety features include mechanical and electrical interlocks, as well as anti-tip brackets.
What type ratings are available for ProLine G2?
ProLine G2 is available in Type 12 and Type 3R ratings.
What are the EMC options for ProLine G2?
EMC options are available for various components, including frames, covers, and doors.
How do I install the internal components?
Internal components can be mounted using grid straps and various mounting brackets provided.
How to Install the P2K18106E Controller
This guide provides step-by-step instructions for installing and configuring the P2K18106E Controller, ensuring proper setup and calibration.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the P2K18106E Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Connect the power supply
Using wire connectors, connect the power supply wires to the designated terminals on the controller. Verify that the connections are secure and insulated.
- Configure the controller settings
Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements and save the settings.
- Calibrate the controller
Perform a calibration check by following the on-screen instructions. Use a multimeter to verify output signals and adjust settings as necessary.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.