nVent F66WBSS - Box Connector, 6.00x6.00, Brushed, SS304
nVent

F66WBSS

UPC: 783510156503


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent F66WBSS is a 6.00 x 6.00-inch feed-through box connector manufactured by nVent. Constructed from SS304 stainless steel with a brushed finish, this connector is designed for wireway systems. It serves as a secure junction point for wire and cable management, offering corrosion resistance suitable for industrial applications. This product is part of nVent's CADDY wire and cable management solutions.
  • Feed-Through Stainless Steel Box Connectors are used inside enclosure when wireway is connected to ensure a tight seal
  • Connects to other wireway sections and fittings and protects wires and cables in frequently hosed down, very wet or highly corrosive applications
  • Brushed finish for a clean aesthetic
  • Designed for feed-through wireway systems
  • Provides a secure junction point for wire and cable management

Specifications

Application
Corrosive Environments;Hygienic Environments;Power Distribution
Application
Hygienic Environments; Corrosive Environments; Power Distribution
Color
Brushed
Color
Unpainted
Finish
No. 2B
Height
44 IN
Height
6
Height
152
Material
Stainless Steel 304
Material
SS304 Stainless Steel
Material
SS304
Modification Services
Yes
Mounting Type
Feed-Through
NEMA Rating
4X
NEMA Rating
4X Watertight, corrosion-resistant
Protection Rating
NEMA Type 4X
Series
nVent CADDY
Size
6.00x6.00
Size
6.00x6.00 inch
Thickness
16 ga
Thickness
1.59 mm
Thickness
51.40mm (2.024")
Type
Box Connector
Type
Box Connector;Industrial Feed-Through Wireway
Weight
1.16 lb
Width
6
Width
152
Width
23 IN
Wireway
Stainless Steel Feed-Through NEMA Type 4X Wireway
Package Dimensions (L x W x H)
12.3 IN x 10 IN x 0.5 IN
Package Dimensions (L x W x H)
31.242 cm x 25.4 cm x 1.27 cm
Package Weight (Imperial)
1.160 L
Package Weight (Metric)
0.526 kg
Gasket and Screws Feed-Through, fits 6.00x6.00, Brushed, SS304

F66WGSS

Gasket and Screws Feed-Through, fits 6.00x6.00, Brushed, SS304
N4X Wireway, Drop Hanger - Fits 6 x 6 - 304SS

1487DL1SS

N4X Wireway, Drop Hanger - Fits 6 x 6 - 304SS
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

T702BIW10

Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

Frequently Asked Questions

What are the dimensions of the nVent F66WBSS box connector?

The nVent F66WBSS box connector measures 6.00 x 6.00 inches (152 x 152 mm).

What material is the nVent F66WBSS box connector made from?

The nVent F66WBSS box connector is constructed from SS304 stainless steel.

What type of finish does the nVent F66WBSS box connector have?

The nVent F66WBSS box connector features a brushed finish.

What is the primary application for the nVent F66WBSS box connector?

The nVent F66WBSS box connector is designed for feed-through wireway systems for wire and cable management.

How to Install the Feed-Through Wireway

This guide provides step-by-step instructions for installing and configuring the Feed-Through Wireway, ensuring proper assembly and secure connections.

Estimated time: 45m

Tools needed:

Screwdriver, Drill, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Gaskets, Terminal connectors, Lockwashers

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the assembly details.

  2. Install the telescope fitting

    Assemble the telescope fitting parts in the correct order, insert the body into the straight section, and adjust to the desired length. Ensure the gasket is properly positioned and secure it with the compression ring and screws.

  3. Anchor the telescope fitting

    If the telescope fitting is used vertically, drill .25 inch diameter holes through the straight section and telescope fitting. Install .25−20x.5 screws from the outside and secure with cap nuts and lockwashers.

  4. Cut the wireway to length

    Cut the wireway body to the desired length, ensuring a square cut. Weld an extra flange to the body and grind off any sharp edges.

  5. Install the swivel nipple

    Position the wireway section, flange gasket, swivel ring, and swivel nipple in order. Secure the swivel nipple with clips, screws, and nuts.

  6. Make box entries

    For box entries, cut out the necessary openings in the enclosure as specified. Position the box connector and gasket inside the enclosure and secure the wireway section to the outside.

  7. Install hangers

    Assemble the hangers as shown in the details and attach them to the wireway flanges in the desired positions.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.