Contact for Pricing
Overview
- Feed-Through Telescope Fittings are for adjusting wireway length without cutting or welding
- Length is easily adjustable from 1.50 inch to 13.50 inch (343 mm)
- Connects to other wireway sections and fittings and protects wires and cables against dust in a broad range of industrial applications
- Integrates with nVent wireway sections for extended cable routing
- Protects wires and cables from dust, debris, and mechanical damage
Specifications
Application | Power Distribution |
Color | Gray |
Color Code | ANSI 61 |
Finish | Powder Coated |
Finish | Painted;Powder Coat |
Height | 44 IN |
Height | 4 |
Height | 102 |
IP Rating | IP54 |
Material | Mild Steel |
Material | Mild Steel;Steel |
Modification Services | Yes |
NEMA Rating | 12 Indoor, dust-resistant |
NEMA Rating | 12 |
Protection Rating | NEMA Type 12 |
Thickness | 14 ga |
Thickness | 1.9 mm |
Thickness | 51.40mm (2.024") |
Type | Industrial Feed-Through Wireway;Telescope Fitting |
Type | Telescope Fitting |
Weight | 6.4 lb |
Width | 4 |
Width | 102 |
Width | 23 IN |
Wireway | Feed-Through NEMA Type 12 Wireway |
Package Dimensions (L x W x H) | 16.25 IN x 5.75 IN x 5.75 IN |
Package Dimensions (L x W x H) | 41.275 cm x 14.605 cm x 14.605 cm |
Package Weight (Imperial) | 7.000 L |
Package Weight (Metric) | 3.175 kg |

LDPH10IG6-A
The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.How to Install the Feed-Through Wireway
This guide provides step-by-step instructions for installing and configuring the Feed-Through Wireway, ensuring proper assembly and connection.
Estimated time: 1h
Tools needed:
Screwdriver, Drill, Wire strippers
Supplies needed:
Mounting screws, Gaskets, Terminal connectors, Cap nuts, Lockwashers
- Assemble the wireway sections
Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the assembly details.
- Install the telescope fitting
Assemble the telescope fitting parts in the correct order, insert the body into the straight section, and adjust to the desired length. Ensure the gasket is properly positioned and secure with screws and nuts.
- Anchor the telescope fitting
If the telescope fitting is used vertically, drill .25 inch diameter holes through the straight section and telescope fitting. Install .25−20x.5 screws from the outside and secure with cap nuts and lockwashers.
- Cut the wireway to length
Cut the wireway body to the desired length, ensuring it is cut squarely. Weld an extra flange to the body and grind off any burrs or sharp edges.
- Install swivel nipples
Position the wireway section, flange gasket, swivel ring, and swivel nipple in the correct order. Secure with clips, screws, and nuts.
- Make box entries
For box entries, make a cutout in the enclosure as specified, position the box connector and gasket inside, and ensure another gasket is placed between the wireway and the enclosure.
- Install hangers
Assemble the hangers according to the provided details, ensuring they are attached to the wireway flanges in various positions as needed.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.