nVent F126L06 - Straight Section Lay-in Hinged-Cover Type 12, 12.00x6.00x6.00, Gray, Steel
nVent

F126L06

UPC: 783510187200


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent F126L06 is a robust 12.00" x 6.00" x 6.00" steel straight section lay-in wireway, designed for demanding industrial environments. Manufactured by nVent, a trusted leader in electrical enclosures and connectivity solutions, this NEMA Type 12 rated wireway provides superior protection for your critical wiring and cabling. Engineered for efficiency and durability, the F126L06 features a hinged cover with quick-release latches, allowing for rapid and convenient access to the interior. This design significantly streamlines installation and maintenance, enabling technicians to lay in wires and cables along the entire run without the need for pulling, a common bottleneck in traditional wire management systems. The lay-in design is particularly advantageous in applications where frequent modifications or additions to wiring are anticipated. Its NEMA Type 12 rating signifies its suitability for indoor use where protection against circulating dust, falling dirt, and dripping or light splashing of oil, coolant, or other non-corrosive liquids is essential. This makes the nVent F126L06 an ideal choice for a wide array of industrial settings, including manufacturing plants, processing facilities, assembly lines, and control rooms. The gray, powder-coated steel construction offers excellent resistance to corrosion and mechanical damage, ensuring long-term performance even in harsh operational conditions. Key features and benefits of the nVent F126L06 include: * **Superior Protection:** NEMA Type 12 rating safeguards against dust, dirt, and oil/coolant ingress. * **Lay-In Design:** Facilitates easy wire and cable installation without pulling, saving time and effort. * **Hinged Cover with Quick-Release Latches:** Provides quick and secure access for maintenance and modifications. * **Durable Steel Construction:** Offers robust protection against physical impact and environmental factors. * **Seamless Integration:** Designed to connect with other nVent wireway components for complete system solutions. When selecting wireway solutions for industrial applications, factors such as environmental protection, ease of installation, and long-term reliability are paramount. The nVent F126L06 excels in all these areas, offering a dependable and efficient method for managing and protecting electrical infrastructure. Its US origin further underscores a commitment to quality manufacturing standards. Trust nVent for your critical wireway needs, ensuring operational continuity and safety.
  • Lay-in NEMA Type 12 Wireway fittings are used primarily in industrial applications to protect wiring against exposure to oil and other contaminants
  • This gasketed wireway features quick-release latches for easy access and an opening on one side so wires and cables can be laid in along the entire run without pulling
  • Lay-in design allows for easy wire and cable installation without pulling
  • Hinged cover with quick-release latches for convenient access and maintenance
  • Durable gray steel construction for industrial environments

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Depth
6 in
Depth
152 mm
Depth
13 IN
Finish
Galvanized;Painted
Finish
Galvanized
Height
44 IN
Height
12
Height
305
IP Rating
IP54
Material
Mild Steel;Steel
Material
Mild Steel
Material
Steel
Modification Services
Yes
Nema Rating
Type 12
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Protection Rating
NEMA Type 12
Sealing Plate Quantity
1
Sealing Plate Type
Flat
Size
12.00x6.00x6.00
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Thickness
14 ga
Type
Straight Section
Type
Industrial Lay-in Wireway;Straight Section
Type Number
Type 12
Weight
8.5 lb
Width
6
Width
152
Width
23 IN
Wireway
Lay-In NEMA Type 12 Wireway
Package Dimensions (L x W x H)
14.75 IN x 8.25 IN x 8 IN
Package Dimensions (L x W x H)
37.465 cm x 20.955 cm x 20.32 cm
Package Weight (Imperial)
8.000 L
Package Weight (Metric)
3.629 kg
Reducer Lay-in Hinged Cover, 12x6 to 4x4, Gray, Steel

F126LRE44

Reducer Lay-in Hinged Cover, 12x6 to 4x4, Gray, Steel
N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray

1485FW1

N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

LDPH10IG6-A

The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

How to Install the Lay-In Wireway

This guide provides step-by-step instructions for installing and sealing a Lay-In Wireway, ensuring proper assembly and connection for effective cable management.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wrench

Supplies needed:

Mounting screws, Gaskets, Nuts, Seal plates

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the assembly details.

  2. Seal the joints

    For joints between lay-in sections, position the LSGQR fitting and install it with a shoulder bolt, ensuring gaskets are visible from above. Rotate the cam to lock the position.

  3. Install box entries

    Make a cutout in the control enclosure as specified, position the box connector and gasket inside, and install a 90° angle sealing plate to secure the connection.

  4. Adjust telescope fitting

    Assemble the compression ring, gasket, and retainer on the telescope fitting body. Insert the body into the straight section and adjust to the desired length.

  5. Anchor the telescope fitting

    Drill .25 inch diameter holes through the sides and bottom of the straight section and telescope fitting. Install .25−20x.5 screws and secure with cap nuts and lockwashers.

  6. Calibrate the wireway

    Ensure all sections are level and securely fastened. Verify that the wireway is properly grounded if used for grounding continuity.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.