nVent F126LRE44 - Reducer Lay-in Hinged Cover, 12x6 to 4x4, Gray, Steel

nVent F126LRE44 Reducer Lay-in Hinged Cover, 12x6 to 4x4, Gray, Steel

UPC: 783510188900


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent F126LRE44 Reducer Lay-In Hinged Cover provides a durable steel transition between 12x6 and 4x4 wireways while maintaining lay-in wire access. Constructed from a 16-gauge steel body and a 12-gauge cover, this reducer cover ensures structural integrity in demanding environments, including control panels, switchgear rooms, and electrical distribution centers. The hinged design allows quick access for wire management and future modifications without removing the cover entirely, reducing installation labor compared to alternative transition methods. Measuring 12.00 x 6.00 x 4.00 inches (305 x 152 x 102 mm), the F126LRE44 integrates seamlessly with nVent wireway systems for conduit size transitions. The gray steel finish resists corrosion and provides EMI shielding for sensitive electronic systems, making it suitable for industrial applications where protection against electromagnetic interference is critical. The cover includes four screws for secure attachment and features a 10.75-inch (273 mm) opening diameter, ensuring ample space for wire routing and access. This reducer cover meets industrial requirements for wireway transitions while maintaining durability and ease of use in high-performance electrical installations.
  • Lay-In Hinged Cover Reducer allows the lay-in feature to be retained when reducing to a smaller wireway size
  • 16-gauge steel body with 12-gauge hinged cover for durability
  • Lay-in wire access maintained during conduit size transitions
  • Gray steel finish resists corrosion and provides EMI shielding
  • Four cover screws secure hinged access for easy wire management

Specifications

Application
Power Distribution
Color
Gray
Color
Grey
Color Code
ANSI 61
Finish
Galvanized
Height
44 IN
Height
305
Height
12 IN
IP Rating
IP54
Material
Mild Steel
Material
Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Reduces From
12.00 x 6.00 in
Reduces From
4.00 x 4.00 in
Reduces To
4.00 x 4.00 in
Reduces To
2.50 x 2.50 in
Sealing Plate Quantity
0
Sealing Plate Type
None
Series
F126LRE44
Size
12x6 to 4x4
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Thickness
14 ga
Type
Reducer
Type
Industrial Lay-in Wireway;Reducer
Type Number
Type 12
Weight
6.4 lb
Width
152
Width
6 IN
Width
23 IN
Wireway
Lay-In NEMA Type 12 Wireway
Package Dimensions (L x W x H)
14 IN x 8 IN x 4.4 IN
Package Dimensions (L x W x H)
35.56 cm x 20.32 cm x 11.176 cm
Package Weight (Imperial)
6.400 L
Package Weight (Metric)
2.903 kg
Reducer Lay-in Hinged Cover, 12x6 to 6x6, Gray, Steel

F126LRE66

Reducer Lay-in Hinged Cover, 12x6 to 6x6, Gray, Steel
Type 3R Wiring Trough - 6x6x60 - Galv/Gray

C3RWT660

Type 3R Wiring Trough - 6x6x60 - Galv/Gray
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

LDPH10IG6-A

The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.
Sealing Plate 90-Degree Angle Lay-in HC Type 12 and 3R, 12.00x6.00, Gray, Steel

F126LSAG

Sealing Plate 90-Degree Angle Lay-in HC Type 12 and 3R, 12.00x6.00, Gray, Steel
Cutoff Fitting Lay-in, 6.00x6.00, Gray, Steel

F66LXL

Cutoff Fitting Lay-in, 6.00x6.00, Gray, Steel
Telescope Fitting Lay-In Hinged Cover, 4.00x4.00, Gray, Steel

F44LA

Telescope Fitting Lay-In Hinged Cover, 4.00x4.00, Gray, Steel
Tee Fitting Lay-in Hinged Cover Outside Top Opening, 6.00x6.00, Gray, Steel

F66LTC

Tee Fitting Lay-in Hinged Cover Outside Top Opening, 6.00x6.00, Gray, Steel

How to Install the Lay-In Wireway

This guide provides step-by-step instructions for installing and sealing a Lay-In Wireway for effective cable management.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wrench

Supplies needed:

Mounting screws, Gaskets, Nuts, Sealing plates

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the installation details.

  2. Seal the joints

    For joints between lay-in sections, position the LSGQR fitting and install it with a shoulder bolt, ensuring the gaskets are visible from above. Rotate the cam to lock the position.

  3. Install box entries

    Make a cutout in the control enclosure for the wireway entry. Position the box connector and gasket inside the enclosure, then install a 90° sealing plate as described in the installation details.

  4. Adjust and anchor telescope fitting

    Assemble the compression ring, gasket, and retainer on the telescope fitting. Insert it into the straight section and adjust to the desired length. Drill holes and install screws to anchor the fitting if necessary.

  5. Calibrate the wireway

    Ensure all sections are level and securely fastened. Check for grounding continuity if the wireway is to be used as ground.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.