nVent AXD20SS - Sequestr Retrofit External Disconnect Type 4X, 34x14x20, Brushed, SS304
nVent

AXD20SS

UPC: 783510171858


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent Sequestr Retrofit External Disconnect (SKU: AXD20SS) is a Type 4X enclosure designed for arc flash mitigation in industrial settings. Constructed from 14-gauge 304 stainless steel with a #4 brushed finish, it offers robust corrosion resistance for indoor and outdoor use. This retrofit solution isolates incoming power from main control panels, enhancing safety during maintenance. It is specifically designed to fit nVent's A28S4 main enclosures and supports up to 200A disconnect switches. Key features include continuously welded seams, a 3-point latch system, quarter-turn slotted latches, and a removable door with hidden hinges for secure sealing against dust and water. The AXD20SS meets stringent industry standards, including UL 508A listing, cUL certification, NEMA Type 3R, 4, 4X, 12, and IEC 60529 IP66 ingress protection. An interlock feature prevents door opening when the disconnect is powered, further reducing arc flash risks. Installation is simplified with included hardware and templates, and it features a preferred disconnect cutout and a provision for pass-through power. Ideal for manufacturing, chemical processing, water treatment, and food/beverage industries requiring enhanced electrical safety for legacy systems.
  • Interlocks with doors of main control cabinet when the disconnect switch is powered ON
  • Maintains UL Type 4X rating
  • Provision for pass-through power into the main cabinet - blank plate for customer modification
  • Preferred disconnect cutout
  • Quarter-turn screwdriver slot and 3-point latch
  • Hidden hinges
  • Bonding provision on door
  • Conductive back panel included
  • Installation hardware and templates included
  • Continuously welded and ground seams all around

Specifications

Application
Controls and Drives; Corrosive Environments; Arc Flash Safety
Color
Unpainted
Depth
511 mm
Depth
20.12 in
Finish
Brushed #4
Height
34.45 in
Height
875 mm
IP Rating
IP66
Material
Stainless Steel
Material
Stainless Steel 304
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
Product Family
Sequestr
Protection Rating
NEMA Type 12
Size
20" Deep Retrofit Kit in
Thickness
1.9 mm
Thickness
14 ga
Type
Stainless Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 4X
Weight
87.8 lb
Width
356 mm
Width
14 IN
Package Dimensions (L x W x H)
22 IN x 17 IN x 38 IN
Package Dimensions (L x W x H)
55.88 cm x 43.18 cm x 96.52 cm
Package Weight (Imperial)
87.800 L
Package Weight (Metric)
39.826 kg
Sequestr Retrofit External Disconnect Type 4X, 34x14x24, Brushed, SS304

AXD24SS

Sequestr Retrofit External Disconnect Type 4X, 34x14x24, Brushed, SS304
Sequestr Retrofit External Disconnect Type 4X, 34x14x18, Brushed, SS304

AXD18SS

Sequestr Retrofit External Disconnect Type 4X, 34x14x18, Brushed, SS304
Sequestr External Disconnect Package 1-Door Type 4X, 72x34x18, Brushed, SS304

A72XD3418SSFTCLP

Sequestr External Disconnect Package 1-Door Type 4X, 72x34x18, Brushed, SS304
Sequestr External Disconnect Package 1-Door Type 4X, 90x40x20, Brushed, SS304

A90XD4020SSFTCLP

Sequestr External Disconnect Package 1-Door Type 4X, 90x40x20, Brushed, SS304
Sequestr External Disconnect Package 3-Door Type 4X, 72x118x18, Brushed, SS304

A72XD3EW18SSFTCLP

Sequestr External Disconnect Package 3-Door Type 4X, 72x118x18, Brushed, SS304
Sequestr External Disconnect Package 2-Door Type 4X, 72x66x18, Brushed, SS304

A72XD6618SSFTCLP

Sequestr External Disconnect Package 2-Door Type 4X, 72x66x18, Brushed, SS304
Sequestr External Disconnect Package 2-Door Type 4X, 72x54x18, Brushed, SS304

A72XD5418SSFTCLP

Sequestr External Disconnect Package 2-Door Type 4X, 72x54x18, Brushed, SS304
Sequestr External Disconnect Package 1-Door Type 4X, 72x28x18, Brushed, SS304

A72XD2818SSFTCLP

Sequestr External Disconnect Package 1-Door Type 4X, 72x28x18, Brushed, SS304
Sequestr External Disconnect Package 1-Door Type 4X, 72x40x18, Brushed, SS304

A72XD4018SSFTCLP

Sequestr External Disconnect Package 1-Door Type 4X, 72x40x18, Brushed, SS304
Sequestr External Disconnect Package 2-Door Type 4X, 90x78x20, Brushed, SS304

A90XD7820SSFTCLP

Sequestr External Disconnect Package 2-Door Type 4X, 90x78x20, Brushed, SS304
Sequestr External Disconnect Package 1-Door Type 4X, 84x40x24, Brushed, SS304

A84XD4024SSFTCLP

Sequestr External Disconnect Package 1-Door Type 4X, 84x40x24, Brushed, SS304
Sequestr External Disconnect Package 2-Door Type 4X, 90x78x24, Brushed, SS304

A90XD7824SSFTCLP

Sequestr External Disconnect Package 2-Door Type 4X, 90x78x24, Brushed, SS304

How to Install the Sequestr External Disconnect Enclosure

This guide provides step-by-step instructions for installing the Sequestr external disconnect enclosure to a control enclosure, ensuring proper mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Volt meter, Wire strippers

Supplies needed:

Mounting screws, Terminal connectors, Hoffman hole seal, Hoffman blank adapter plate

  1. Power Down the System

    Turn off the local disconnect in the control enclosure and the feeder disconnect. Wear appropriate Personal Protective Equipment (PPE) and test for power using a volt meter.

  2. Prepare the Control Enclosure

    Remove the existing disconnect from the control enclosure and seal the hole with a Hoffman hole seal. Cover all components in the control enclosure to protect them.

  3. Mount the Sequestr Enclosure

    Remove the subpanel from the Sequestr enclosure. Drill a hole for the power line entrance, then hang the Sequestr enclosure on the control enclosure using M6x16mm bolts and secure it with washer head cap screws.

  4. Install Circuit Breaker/Disconnect Switch

    Drill mounting holes for the circuit breaker or disconnect switch on the panel. Install the device according to the manufacturer's instructions and secure the panel back into the Sequestr enclosure.

  5. Connect Wiring

    Install conduit and connect wires to the incoming side of the circuit breaker/disconnect switch in the Sequestr enclosure. Ensure all connections are secure and properly insulated.

  6. Power Up the System

    Remove any protective coverings, ensure the operator handle is in the 'OFF' position, close and latch the Sequestr and control enclosure doors, then turn on the feeder disconnect switch and verify system operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.