Authorized nVent Distributor
nVent A90XD7820SSFTCLP - Sequestr External Disconnect Package 2-Door Type 4X, 90x78x20, Brushed, SS304

nVent A90XD7820SSFTCLP Sequestr External Disconnect Package 2-Door Type 4X, 90x78x20, Brushed, SS304

UPC: 783510279462


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Enhance safety and operational efficiency in industrial environments with the nVent Sequestr External Disconnect Package (SKU: A90XD7820SSFTCLP). This robust solution is engineered to significantly mitigate arc flash hazards when performing maintenance or adjustments on interior enclosure components. By providing a secure external isolation point for incoming power, it effectively separates the main power supply from the primary enclosure, allowing personnel to work with greater confidence and reduced risk. The enclosure is meticulously constructed from high-quality 304 stainless steel, a material renowned for its exceptional resistance to corrosion and its durability in both non-corrosive and mildly corrosive atmospheric conditions. This makes the Sequestr package an ideal choice for a wide array of applications, including chemical processing plants, food and beverage facilities, wastewater treatment operations, and general manufacturing settings, where environmental resilience is paramount. Its Type 4X rating ensures superior protection against water and dust ingress, safeguarding sensitive electrical equipment from the elements. Each Sequestr External Disconnect Package includes a main enclosure and a dedicated Sequestr box, designed for seamless integration. The disconnect switch and fuse block or circuit breaker are conveniently mounted within the external Sequestr enclosure. Terminal connections are strategically placed to facilitate the efficient transfer of power to the main enclosure, simplifying installation and wiring. Key benefits and features include: * **Arc Flash Mitigation:** Dramatically reduces arc flash risk by isolating incoming power externally. * **Durable Construction:** Manufactured from 304 stainless steel for superior corrosion resistance and longevity. * **Environmental Protection:** Type 4X rating provides robust defense against water and dust. * **Integrated Solution:** Package includes main enclosure and Sequestr box for a complete system. * **Flexible Retrofitting:** Sequestr boxes are available for separate purchase, enabling retrofitting of existing enclosures. * **Simplified Maintenance:** Facilitates safer and more efficient access to interior enclosure components. This package is particularly valuable in industries where downtime is costly and personnel safety is a top priority. The ability to isolate power externally means that routine inspections, component replacements, or troubleshooting can be performed without exposing workers to the inherent dangers of live electrical systems. The 90x78x20 inch dimensions offer ample space for standard disconnect and protection devices, while the two-door design of the main enclosure allows for convenient access and organization of internal wiring and components. nVent is a globally recognized leader in electrical enclosure solutions, known for its commitment to innovation, quality, and safety. The Sequestr External Disconnect Package exemplifies this dedication, offering a reliable and effective solution for managing electrical hazards in demanding industrial environments. Professionals trust nVent products for their performance, durability, and adherence to stringent industry standards, ensuring peace of mind and operational continuity.
  • Package includes a main enclosure and a Sequestr box.
  • Main enclosure 12 gauge Type 304 stainless steel
  • Sequestr enclosure is 14 gauge Type 304 stainless steel
  • Seams continuously welded and ground smooth
  • Interlocks doors of main control cabinet when disconnect switch is powered ON
  • Mechanical interlock on main control enclosure activated by primary door, preventing secondary door from being opened first
  • Provision for pass-through power into the main enclosure
  • Preferred Disconnect cutout
  • Quarter-turn, screwdriver slot latch on Sequestr Enclosure
  • Heavy-duty 3-point latching mechanism operated by Type 316L stainless steel PowerGlide padlocking handle on all doors

Specifications

Application
Arc Flash Safety; Controls and Drives; Corrosive Environments
Color
Unpainted
Conductive Panel
A90PM78G
Depth
511 mm
Depth
20.12 in
Finish
Brushed #4
Height
2,289 mm
Height
90.12 in
Material
Stainless Steel
Material
Stainless Steel 304
Modification Services
Yes
NEMA Rating
4X Watertight, corrosion-resistant
Panel
A90PM78
Panel Size
1981 x 1829 mm
Panel Size
78.00 x 72.00 in
Product Family
Sequestr
Protection Rating
NEMA Type 12
Size
90.12 x 78.5 x 20.12 in
Thickness
1.98 mm
Thickness
14 ga
Type
Stainless Steel Freestanding Industrial Disconnect Enclosures
Weight
1,205 lb
Width
78.5 in
Width
1,994 mm
Package Dimensions (L x W x H)
85 IN x 38 IN x 100 IN
Package Dimensions (L x W x H)
215.9 cm x 96.52 cm x 254 cm
Package Weight (Imperial)
1205.000 L
Package Weight (Metric)
546.588 kg
Sequestr External Disconnect Package 2-Door Type 4X, 90x78x24, Brushed, SS304

A90XD7824SSFTCLP

Sequestr External Disconnect Package 2-Door Type 4X, 90x78x24, Brushed, SS304
Switch Box Extension, 3.5 Cubic Inches, 7/8 Inch Maximum Adjustable Depth, Pre-Galvanized Steel, Fits Snugly Inside All Single Gang Switch Boxes, Furnished with 1-1/4 Inch Long Screws for Mounting

SBEX

Switch Box Extension, 3.5 Cubic Inches, 7/8 Inch Maximum Adjustable Depth, Pre-Galvanized Steel, Fits Snugly Inside All Single Gang Switch Boxes, Furnished with 1-1/4 Inch Long Screws for Mounting
Sequestr External Disconnect Package 1-Door Type 4X, 72x28x18, Brushed, SS304

A72XD2818SSFTCLP

Sequestr External Disconnect Package 1-Door Type 4X, 72x28x18, Brushed, SS304
Sequestr External Disconnect Package 2-Door Type 4X, 84x78x24, Brushed, SS304

A84XD7824SSFTCLP

Sequestr External Disconnect Package 2-Door Type 4X, 84x78x24, Brushed, SS304
Sequestr External Disconnect Package 3-Door Type 4X, 72x100x18, Brushed, SS304

A72XD3EQ18SSFTCLP

Sequestr External Disconnect Package 3-Door Type 4X, 72x100x18, Brushed, SS304
Sequestr External Disconnect Package 3-Door Type 4X, 84x118x24, Brushed, SS304

A84XD3EW24SSFTCLP

Sequestr External Disconnect Package 3-Door Type 4X, 84x118x24, Brushed, SS304
Sequestr External Disconnect Package 3-Door Type 4X, 90x118x24, Brushed, SS304

A90XD3EW24SSFTCLP

Sequestr External Disconnect Package 3-Door Type 4X, 90x118x24, Brushed, SS304
Sequestr External Disconnect Package 3-Door Type 4X, 84x118x18, Brushed, SS304

A84XD3EW18SSFTCLP

Sequestr External Disconnect Package 3-Door Type 4X, 84x118x18, Brushed, SS304

How to Safely Handle and Install Large Hoffman Enclosures

This guide provides instructions for safely handling and installing large Hoffman enclosures, emphasizing precautions to prevent injury and equipment damage.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device (e.g., crane), Slings with load-rated hooks or shackles, ROLL•A•LIFT™ or similar device (for some models)

Supplies needed:

3000 lb.-rated chain or strap (for securing to forklift mast), Rigging equipment (for overhead lifting)

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and all personnel are at a safe distance.

  2. Prepare for Movement

    Ensure the enclosure is stabilized before removing any strapping. Verify that the lifting equipment (forklift or overhead device) has a sufficient load rating for the enclosure's weight and size. Only trained and authorized personnel should operate the lifting equipment.

  3. Position Forklift Forks

    For forklift handling, spread the forks to the maximum distance or as dictated by the skid width. Enter the skid from the rear (Side A) of the enclosure. Position the enclosure carefully on the forks, keeping the load against the carriage/mast and tilting the load backward towards the mast.

  4. Secure Enclosure to Forklift

    If using a forklift, secure the enclosure to the forklift mast before moving. Insert a 3000 lb.-rated chain or strap through the eye bolts provided on top of the enclosure and fasten it securely to the forklift mast assembly. Ensure sufficient tension to prevent tipping.

  5. Lift and Transport Enclosure

    Lift the enclosure a minimum distance so the skid is just clear of the floor. Start and stop the forklift slowly and gradually, avoiding jerky movements. Drive slowly with the forks carried as low to the ground as possible. Never attempt to move more than one enclosure at a time.

  6. End Loading/Unloading (if applicable)

    For end loading/unloading on trailers, spread forks to match pallet end slot openings and enter from the narrow side (C or D). Secure the enclosure to the forklift mast using chains or straps. Tilt the mast to take weight off the opposite end and slide/push the enclosure as required. Do not use chains or straps to lift the enclosure.

  7. Overhead Lifting (if applicable)

    If using overhead lifting, attach rigging to the eye bolts, ensuring the angle between lifting cables and the vertical does not exceed 45 degrees. Use slings with adequate load-rated hooks or shackles. Ensure the load rating of the lifting device and rigging is sufficient. Do not use ropes or cables through eye bolts.

  8. Final Placement

    Once the enclosure is at its final location, carefully position it. Ensure it is stable and permanently installed according to any specific product instructions not covered in this general handling guide. Refer to the nameplate or datasheet for model-specific details.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.