nVent A62H60DLP - Two-Door with Floorstand Type 4, 62.06x60.06x12.06, Gray, Steel
nVent

A62H60DLP

UPC: 783510264109


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent Type 4 Enclosure (SKU: A62H60DLP) is a robust, two-door industrial-grade housing designed to safeguard critical control systems, instrumentation, and automation components in challenging environments. Engineered with a durable gray steel construction and protected by a high-performance polyester powder coating, this enclosure delivers unmatched resistance to moisture, dust, and non-corrosive contaminants—making it an essential asset for outdoor installations, food processing facilities, and other wet or high-hygiene applications. The Type 4 rating ensures compliance with stringent NEMA and IP standards, providing reliable protection against splashing water, hose-directed liquids, and airborne particulates, while the continuous hinge with clamps and integrated floor stand offers superior structural integrity and ease of access for maintenance and cleaning beneath the unit. Designed for versatility and long-term performance, the nVent Type 4 Enclosure supports flexible internal configurations, allowing equipment to be mounted on either solid panels or modular racks. This adaptability simplifies integration with existing control systems, enabling engineers to optimize space and airflow while maintaining compliance with industry-specific safety and sanitation protocols. The floor stand elevates the enclosure, providing additional clearance for cleaning and reducing the risk of contamination in food-grade or pharmaceutical environments. Additionally, the continuous hinge design ensures smooth operation and secure closure, while the powder-coated finish resists chipping, fading, and corrosion—extending the product’s lifespan even in harsh or corrosive atmospheres. Selecting the right industrial enclosure is critical to protecting sensitive electronics and ensuring operational reliability. Professionals in industries such as food and beverage processing, water treatment, chemical handling, and outdoor telecommunications rely on Type 4 enclosures like the nVent A62H60DLP to meet regulatory requirements and mitigate environmental risks. The Type 4 rating is particularly valued in applications where exposure to moisture, cleaning agents, or high-pressure washdowns is common, as it provides a sealed barrier that prevents ingress of liquids and particulates. nVent, a global leader in thermal management and electrical protection solutions, is trusted for its engineering excellence and adherence to rigorous quality standards, ensuring that every enclosure delivers consistent performance and durability. Installation of the nVent Type 4 Enclosure is straightforward, with pre-drilled mounting holes and a modular design that accommodates various mounting orientations. The floor stand not only enhances stability but also improves accessibility for technicians, reducing downtime during inspections or repairs. For outdoor applications, the enclosure’s corrosion-resistant properties and UV-stable coating ensure long-term performance, even in extreme weather conditions. Whether deployed in a factory floor, processing plant, or remote telecom site, this enclosure provides a secure, compliant, and low-maintenance housing solution for critical control systems. Backed by nVent’s reputation for innovation and reliability, the A62H60DLP Type 4 Enclosure is a trusted choice for engineers and facility managers seeking a durable, high-performance solution for protecting sensitive equipment. With its combination of rugged construction, flexible mounting options, and compliance with industry standards, this enclosure delivers peace of mind in even the most demanding environments.
  • Seams continuously welded and ground smooth
  • Body stiffeners for added strength
  • Removable centerpost permits easy panel installation
  • Panel supports
  • Return flange around three sides of door and along top of enclosure opening channels away liquids and contaminants
  • Stainless steel door clamps on three sides of each door assure water-tight seal
  • Heavy gauge continuous hinge with stainless steel hinge pin
  • Hasp and staple for padlock
  • Data pocket is high-impact thermoplastic
  • 12-in. floor stands bolted-on to enclosure

Specifications

Application
Controls and Drives;Power Distribution
Application
Power Distribution; Controls and Drives
Body Stiffener
533 mm
Body Stiffener
21 in
Body Stiffener
0
Clamp Quantity
16
Color
Gray
Color Code
ANSI 61
Conductive Panel
A60P60G
Depth
12.06
Depth
306
Depth
306 mm
Finish
Powder Coated
Height
62.06
Height
1,576
Height
1,576 mm
IP Rating
IP66
Material
Steel
Modification Services
Yes
Mounting Type
Floorstand
Nema Rating
Type 4
NEMA Rating
4
NEMA Rating
4 Watertight
Panel
A60P60
Panel Size
533 mm
Panel Size
21 in
Protection Rating
NEMA Type 12
Size
62.06x60.06x12.06 in
Size
62.06x60.06x12.06
Thickness
51.40mm (2.024")
Thickness
2.66 mm
Thickness
12 ga
Type
Mild Steel Freestanding Industrial Enclosures
Type Number
Type 4
Weight
471 lb
Width
60.06
Width
1,526
Width
1,526 mm
Package Dimensions (L x W x H)
68 IN x 30 IN x 85 IN
Package Dimensions (L x W x H)
172.72 cm x 76.2 cm x 215.9 cm
Package Weight (Imperial)
471.000 L
Package Weight (Metric)
213.646 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A24R208NK Controller

This guide provides step-by-step instructions for installing and configuring the A24R208NK Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the A24R208NK controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure that the connections are secure and insulated.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage as specified in the manual.

  4. Configure the controller settings

    Access the controller's configuration menu using the interface. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure the controller operates accurately. This may involve adjusting settings based on feedback from connected sensors.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.