Overview
- Drip shield top and seam-free sides, front, and back protect from rain, snow, or sleet
- Slip-on removable cover fastened with plated steel screws along bottom edge
- Handles on larger sizes (see table)
- Embossed mounting holes on back of enclosure
- Knockouts in bottom of 16 and 14 gauge enclosures
- Provision for padlocking
- No gasketing
- Enclosures are finished with paint over plated surfaces
- Top and bottom thickness gauge is the same as the body thickness gauge unless otherwise noted in table
Specifications
Application | Power Distribution |
Body Style | B |
Body Thickness | 16 ga |
Color | Gray |
Color Code | ANSI 61 |
Depth | 8 in |
Depth | 13 IN |
Depth, Maximum | 8 |
Depth, Minimum | 8 |
Door Thickness | 14 ga |
Door Thickness | 16 ga |
Finish | Galvanized |
Height | 44 IN |
Height | 24 in |
IP Rating | IP32 |
Knockout Pattern | C-D-E-F-G |
Knockouts | True |
Knockouts Included | Yes |
Material | Galvanized Steel |
Material | Mild Steel;Steel |
Material | Steel |
Modification Services | Yes |
Mounting | 28;330 mm;mm |
Mounting | Wall Mounting Brackets Available |
Mounting | 1.12;13 in;in |
Mounting Type | Horizontal Mounting |
NEMA Rating | Type 3R |
NEMA Rating | NEMA 6 |
NEMA Rating | 3r |
Protection Rating | NEMA Type 3R |
Series | A |
Size | 24x16x8 inches |
Size | 24.00x16.00x8.00 in |
Type | Pull and Junction Boxes |
Type | Screw-Cover Junction Boxes Type 3R |
Type Number | Type 3R |
Weight | 31 lb |
Width | 406 mm |
Width | 16 IN |
Package Dimensions (L x W x H) | 28 IN x 22 IN x 10 IN |
Package Dimensions (L x W x H) | 71.12 cm x 55.88 cm x 25.4 cm |
Package Weight (Imperial) | 31.000 L |
Package Weight (Metric) | 14.062 kg |
How to Install the A24R168 Controller
This guide provides step-by-step instructions for installing and configuring the A24R168 Controller for optimal performance.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors, Padlock staple
- Mount the controller
Secure the A24R168 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the wiring
Strip the ends of the wires and connect them to the appropriate terminals on the controller. Use wire connectors to ensure a secure connection.
- Install the padlock staple
Push the padlock staple through the slot in the bottom of the enclosure from the inside until it snaps in place to secure the enclosure.
- Verify connections
Use a multimeter to check the voltage and ensure all connections are secure and functioning correctly before powering on the controller.
- Power on the controller
Turn on the power supply to the controller and observe the indicator lights to confirm it is operating as expected.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.