nVent A20HS1610GQRLP - Fiberglass Disconnect Type 4X, 20.19x16.25x10.00, Lt Gray, Fiberglass
nVent

A20HS1610GQRLP

UPC: 783510132330


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent Fiberglass Disconnect Enclosure (SKU A20HS1610GQRLP) offers robust protection for disconnect switches in demanding industrial environments. Constructed from durable fiberglass-reinforced material, this enclosure meets UL 508A Listed and cUL Listed standards, along with NEMA/EEMAC Type 3, 3R, 4, 4X, 12, and 13 ratings, and IEC 60529 IP66. Its material provides excellent temperature and chemical resistance, with sealed seams for watertight and dust-tight performance. Key specifications include dimensions of 20.19 x 16.25 x 10.00 inches. The enclosure features a light gray finish, both inside and out. Doors are secured with Type 304 stainless steel slotted quarter-turn latches for reliable closure. It includes a bracket affixed to the door for attaching a disconnect door catch (interlock), facilitating secure operation. The fiberglass material is easily workable for modifications. This enclosure is suitable for applications requiring protection from corrosive elements and harsh weather, including chemical processing, water and wastewater treatment, food and beverage, and general manufacturing. Its halogen-free material ensures compliance with specific environmental requirements. Optional panels are available for customization.
  • Fiberglass-reinforced material has excellent temperature and chemical resistance qualities and exhibits outstanding physical properties
  • Seams are sealed; no holes or knockouts
  • Seamless foam-in-place gasket assures water-tight and dust-tight seal
  • Fiberglass material is easily drilled, filed or sawed
  • Hinges are fiberglass reinforced polyester
  • Doors are secured with Type 304 stainless steel slotted quarter-turn latches
  • Data pocket is high-impact thermoplastic
  • Copper flashed steel collar studs for mounting optional panels and terminal block kits
  • Holes provided in body for mounting disconnect operating handle and operating mechanism; disconnect operating handle not included
  • Internal grounding provisions for quarter-turn latches

Specifications

Application
Arc Flash Safety; Corrosive Environments; Controls and Drives
Application
Arc Flash Safety;Controls and Drives;Corrosive Environments
Color
Gray
Color
Grey
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Conductive Panel
A20P16G
Depth
10 IN
Depth
254 mm
Finish
Smooth Matte
Height
513 mm
Height
20.19
IP Rating
IP66
Latch Quantity
2
Material
Fiberglass
Material Quality
Fiberglass
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
21.81 x 10.00 in
NEMA Rating
4X
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
Nema Rating
Type 4X, 12, and 13
Panel
A20P16
Panel Size
432 x 330 mm
Panel Size
17.00 x 13.00 in
Protection Rating
NEMA Type 4X
Size
20.19x16.25x10.00 in
Size
20.19x16.25x10.00
Size
20.19x16.25x10.00 inches
Thickness
0.12 in
Thickness
51.40mm (2.024")
Type
Fiberglass Wall Mounted Industrial Disconnect Enclosures
Type Number
Type 3R
Weight
22.3 lb
Width
16.25
Width
413 mm
Package Dimensions (L x W x H)
25.1 IN x 19.6 IN x 14.3 IN
Package Dimensions (L x W x H)
63.754 cm x 49.784 cm x 36.322 cm
Package Weight (Imperial)
22.300 L
Package Weight (Metric)
10.115 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A20HS1610GQRLP Disconnect Device

This guide provides step-by-step instructions for installing the A20HS1610GQRLP disconnect device in a wall-mounted enclosure.

Estimated time: 45m

Tools needed:

Drill, Screwdriver, Wire strippers

Supplies needed:

Mounting screws, Operating handle, Door catch

  1. Drill mounting holes

    Drill the necessary mounting holes in the panel according to the specific disconnect device being installed. Refer to the disconnect manufacturer's instructions for precise locations.

  2. Install the operating handle

    Attach the operating handle to the enclosure flange using the holes provided. Ensure to follow the disconnect manufacturer's instructions for proper installation.

  3. Mount the disconnect device

    Install the disconnect device onto the panel. Follow the manufacturer's instructions for installation and any necessary adjustments.

  4. Install the door catch

    Install the door catch, provided by the disconnect manufacturer, on the bracket welded or bonded to the inside of the enclosure door. Adjust the door catch to properly interlock with the disconnect operating handle as per the manufacturer's instructions.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.