Authorized nVent Distributor
nVent UU504020 - Ultrx Enclosure Solid Door Type 4X, 500x400x200mm, Lt Gray, Fiberglass

nVent UU504020 Ultrx Enclosure Solid Door Type 4X, 500x400x200mm, Lt Gray, Fiberglass

UPC: 783510336806


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent Ultrx Enclosure (SKU: UU504020) is a fiberglass, solid-door enclosure designed for industrial environments requiring NEMA Type 4X protection. Measuring 500x400x200mm, this enclosure provides a lightweight yet durable housing for electrical and electronic components in harsh conditions. Its fiberglass construction resists corrosion, chemicals, and UV exposure, ensuring long-term performance in aggressive atmospheres like chemical processing, water treatment, and food manufacturing. The solid door design enhances protection against water spray, dust, and corrosive agents, meeting NEMA Type 4X standards. With a light gray finish, the enclosure is non-conductive and easy to install, reducing labor and maintenance costs. This enclosure is part of the Ultrx series, which includes multiple sizes (e.g., 500x400x300mm, 600x600x200mm) for varied application needs. Ideal for outdoor infrastructure and industrial facilities, the Ultrx Enclosure delivers reliable protection for critical equipment.
  • Compression-molded fiberglass material has excellent temperature and chemical resistance qualities and exhibits outstanding physical properties, including high-impact resistance
  • Fiberglass is easily punched, drilled, filed or sawed
  • Seamless foam-in-place gasket assures water-tight and dust-tight seal
  • Enclosure may be rotated 180 degrees for left and right hinging
  • Molded-in drip shields are standard with each enclosure
  • Impact-resistant polycarbonate window is permanently bonded in place
  • Fiberglass mounting brackets and stainless steel attachment screws are provided with each enclosure
  • Unique hinge design allows for standard 180 degree door opening with a maximum opening of 270 degrees
  • Door hinges are replaceable
  • Type 316 stainless steel quarter-turn latch

Specifications

Application
Controls and Drives;Corrosive Environments
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Conductive Panel
A20P16G
Cubic Capacity
2637 in3
Depth
8.98 in
Depth
228 mm
Depth
228
Door Style
Solid
Door Type
Solid
External Dimensions
513 x 413 mm
External Dimensions
20.20 x 16.26 in
Finish
Smooth Matte
Height
513 mm
Height
20.2 in
Internal Dimensions
119 x 119 x 92 mm
Internal Dimensions
19.53 x 15.59 x 8.66 in
IP Rating
IP66
Material
Fiberglass
Material Quality
Fiberglass
Modification Services
Yes
Mounting
14.13 x 18.07 in
Mounting
Wall Mounting Brackets Available
NEMA Rating
4X Watertight, corrosion-resistant
NEMA Rating
4X
Nema Rating
Type 4X
Panel
A20P16
Panel Size
17.00 x 12.99 in
Panel Size
432 x 330 mm
Product Family
Ultrx
Protection Rating
NEMA Type 12
Series
ULTRX
Size
500x400x200 mm
Size
20.20 x 16.26 in
Thickness
0.15 in
Thickness
51.40mm (2.024")
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Type Number
Type 3R
Weight
21.8 lb
Width
413 mm
Width
413
Width
16.26 in
Package Dimensions (L x W x H)
24.7 IN x 18.1 IN x 11.3 IN
Package Dimensions (L x W x H)
62.738 cm x 45.974 cm x 28.702 cm
Package Weight (Imperial)
25.000 L
Package Weight (Metric)
11.340 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Connect Conduit to the UU504020 Enclosure

Instructions for connecting conduit to the UU504020 enclosure, ensuring proper grounding and environmental sealing.

Estimated time: 15m

Tools needed:

Screwdriver, Wire strippers

Supplies needed:

UL listed or recognized conduit hubs, Grounding bushing, Jumper wires

  1. Prepare Conduit Hubs

    Connect the UL listed or recognized conduit hubs to the conduit. Ensure the hubs have the same environmental type rating as the enclosure.

  2. Mount the Enclosure

    Mount the UU504020 enclosure using the mounting holes located in the base, external to the equipment cavity. Ensure the enclosure is securely fastened.

  3. Connect Conduit to Enclosure

    Connect the prepared conduit hubs to the enclosure.

  4. Install Grounding

    WARNING: This composite enclosure does not automatically provide grounding between conduit connections. Install a grounding bushing and use jumper wires as part of the installation to ensure proper grounding.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.