nVent A1086CHSCFGW - Continuous Hinge Screw-Cover Window 4X, 10x8x6, Light Gray, Fiberglass
nVent

A1086CHSCFGW

UPC: 783510312107


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A1086CHSCFGW Continuous Hinge Screw-Cover Window Enclosure is a premium fiberglass solution designed for demanding industrial environments where durability, security, and accessibility are critical. Engineered with a Type 4X NEMA rating, this enclosure delivers unmatched protection against corrosion, moisture, dust, and harsh chemicals, making it ideal for outdoor installations, chemical processing plants, water treatment facilities, and marine applications. The light gray fiberglass construction ensures long-term resistance to UV degradation, salt spray, and extreme temperatures, while maintaining a professional aesthetic that blends seamlessly into facility designs. At the heart of this enclosure’s functionality is its continuous hinge design, which provides a secure seal and smooth, unobstructed access to internal components. Unlike traditional enclosures with separate hinges, the continuous hinge distributes stress evenly, reducing wear and tear over time. Paired with double latching mechanisms, this design ensures tamper resistance and enhanced security for sensitive equipment. The screw-cover window feature allows for easy monitoring of internal gauges, displays, or indicators without compromising the enclosure’s protective integrity. The A1086CHSCFGW’s dimensions (10.00" x 8.00" x 6.00") make it a versatile choice for housing control panels, circuit breakers, sensors, or communication devices in both indoor and outdoor settings. Its fiberglass material is inherently non-conductive, providing an added layer of safety in electrical applications. Installation is straightforward, with pre-drilled mounting holes and a design that accommodates standard hardware, reducing labor time and costs. The light gray finish not only meets aesthetic requirements but also reflects heat, further protecting internal components from thermal stress. nVent, a global leader in electrical and thermal management solutions, has engineered this enclosure to meet the rigorous demands of industries such as oil and gas, utilities, manufacturing, and telecommunications. With decades of expertise in protective housing solutions, nVent’s products are trusted by professionals who require reliability under the most challenging conditions. The A1086CHSCFGW is backed by nVent’s commitment to innovation, quality, and customer support, ensuring peace of mind for specifiers and end-users alike. Whether you’re upgrading an existing system or designing a new installation, the nVent A1086CHSCFGW Continuous Hinge Screw-Cover Window Enclosure offers the durability, security, and functionality needed to protect critical infrastructure. Its combination of fiberglass construction, Type 4X rating, and thoughtful design features makes it a standout choice for professionals who prioritize performance and longevity in their equipment housing solutions.
  • Compression-molded fiberglass has outstanding chemical- and temperature-resistance qualities and exhibits excellent weatherability and physical properties
  • Fiberglass is easily punched, drilled, filed or sawed
  • Gasket assures water-tight and dust-tight seal
  • Polyester mounting brackets and stainless steel attachment screws are provided with each enclosure
  • Scratch-resistant polycarbonate windows are permanently bonded in place
  • Molded-in-place threaded brass inserts and plated steel screws are provided for mounting optional panels and terminal block kits
  • Removable hinged cover attached to body with Type 316 stainless steel hinge pin
  • Screw-cover enclosures are secured with two captivated Type 316 stainless steel slotted cover screws
  • Enclosures with quick-release latches have corrosion-resistant polyester latches located in corners that provide unobstructed access to enclosure
  • Hinge pin and bail are corrosion-resistant Type 316 stainless steel

Specifications

Aluminum Panel
A10P8AL
Application
Controls and Drives;Corrosive Environments
Color
Gray
Color
Grey
Color
Light Gray
Color Code
RAL 7035
Cover Style
Solid Screw
Depth
152 mm
Depth
6
Depth
152
Finish
Smooth Matte
Height
10 IN
Height
254 mm
IP Rating
IP66
Material
Fiberglass
Material Quality
Fiberglass
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
10.94 x 6.00 in
NEMA Rating
4X Watertight, corrosion-resistant
NEMA Rating
4X
Overall Dimensions
10.50 x 8.50 in
Overall Dimensions
114 x 88 mm
Panel Size
8.75 x 6.88 in
Panel Size
222 x 175 mm
Protection Rating
NEMA Type 12
Size
10.00x8.00x6.00 in
Steel Panel
A10P8
Thickness
0.15 in
Thickness
51.40mm (2.024")
Type
Window Screw Cover
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Type Number
Type 13
Weight
4.3 lb
Width
8 in
Width
203 mm
Package Dimensions (L x W x H)
13 IN x 11.2 IN x 8.8 IN
Package Dimensions (L x W x H)
33.02 cm x 28.448 cm x 22.352 cm
Package Weight (Imperial)
4.300 L
Package Weight (Metric)
1.951 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A1086CHSCFGW Controller

This guide provides step-by-step instructions for installing and configuring the A1086CHSCFGW Controller, ensuring proper wiring and setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the A1086CHSCFGW controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Connect the power and signal wires to the appropriate terminals on the controller. Use terminal connectors to ensure secure connections.

  3. Ground the equipment

    Ground the controller according to the National Electrical Code requirements. Ensure that all conduit entries are properly grounded to maintain system safety.

  4. Verify connections

    Use a multimeter to verify that all connections are secure and that there are no short circuits. Check voltage levels to ensure proper operation.

  5. Configure the controller

    Follow the manufacturer's instructions to program the controller settings according to your system requirements.

  6. Calibrate the system

    Perform any necessary calibration procedures as outlined in the user manual to ensure optimal performance of the controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.