nVent A1086CHSCFG - Continuous Hinge Screw-Cover Enclosure 4X, 10x8x6, Light Gray, Fiberglass
nVent

A1086CHSCFG

UPC: 783510296803


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A1086CHSCFG Continuous Hinge Screw-Cover Enclosure (SKU: A1086CHSCFG) is a 10×8×6 inch fiberglass enclosure designed for harsh industrial environments. This light gray enclosure meets NEMA Type 4X and IP66 standards, providing protection against dust, water ingress, and corrosive atmospheres. The fiberglass construction resists chemicals, moisture, and UV exposure, ensuring long-term durability in demanding conditions. The continuous hinge design eliminates separate hardware components, reducing failure points and simplifying installation. A double latching mechanism with corner latches enhances security for critical control systems, while tool-free screw-cover access enables quick maintenance. Standard mounting provisions accommodate flexible installation. Certified to UL 508A (Type 3, 3R, 4, 4X, 12, 13) and cUL Listed per CSA C22.2 No 94, this enclosure is ideal for oil and gas, chemical processing, water treatment, and renewable energy applications. Protect PLCs, motor starters, and control panels with a corrosion-resistant, high-integrity housing.
  • Compression-molded fiberglass has outstanding chemical- and temperature-resistance qualities and exhibits excellent weatherability and physical properties
  • Fiberglass is easily punched, drilled, filed or sawed
  • Gasket assures water-tight and dust-tight seal
  • Polyester mounting brackets and stainless steel attachment screws are provided with each enclosure
  • Scratch-resistant polycarbonate windows are permanently bonded in place
  • Molded-in-place threaded brass inserts and plated steel screws are provided for mounting optional panels and terminal block kits
  • Removable hinged cover attached to body with Type 316 stainless steel hinge pin
  • Screw-cover enclosures are secured with two captivated Type 316 stainless steel slotted cover screws
  • Enclosures with quick-release latches have corrosion-resistant polyester latches located in corners that provide unobstructed access to enclosure
  • Hinge pin and bail are corrosion-resistant Type 316 stainless steel

Specifications

Aluminum Panel
A10P8AL
Application
Corrosive Environments; Controls and Drives
Application
Controls and Drives;Corrosive Environments
Color
Gray
Color
Grey
Color
Light Gray
Color Code
RAL 7035
Cover Style
Solid Screw
Depth
152 mm
Depth
6
Depth
152
Finish
Smooth Matte
Height
10 IN
Height
254 mm
IP Rating
IP66
Material
Fiberglass
Material Quality
Fiberglass
Modification Services
Yes
Mounting
10.94 x 6.00 in
Mounting
Wall Mounting Brackets Available
Nema Rating
Type 4X
NEMA Rating
4X Watertight, corrosion-resistant
NEMA Rating
4X
Overall Dimensions
114 x 88 mm
Overall Dimensions
10.50 x 8.50 in
Panel Size
8.75 x 6.88 in
Panel Size
222 x 175 mm
Protection Rating
NEMA Type 12
Size
10.00x8.00x6.00
Size
10.00x8.00x6.00 in
Steel Panel
A10P8
Thickness
0.15 in
Thickness
51.40mm (2.024")
Type
Solid Screw Cover
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Type Number
Type 13
Weight
4.3 lb
Width
203 mm
Width
8 in
Package Dimensions (L x W x H)
13.1 IN x 11.2 IN x 8.9 IN
Package Dimensions (L x W x H)
33.274 cm x 28.448 cm x 22.606 cm
Package Weight (Imperial)
4.300 L
Package Weight (Metric)
1.951 kg
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
1/2 Inch, 90 Degree, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN20DA

1/2 Inch, 90 Degree, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A1086CHSCFG Controller

This guide provides step-by-step instructions for installing and configuring the A1086CHSCFG controller, ensuring proper wiring and setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the A1086CHSCFG controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Connect the power and signal wires to the appropriate terminals on the controller. Use terminal connectors to ensure a secure connection.

  3. Ground the equipment

    Ground the controller according to the National Electrical Code requirements. Ensure that all conduit entries are properly grounded to maintain system safety.

  4. Verify connections

    Use a multimeter to verify that all connections are secure and that there is continuity in the grounding system.

  5. Configure the controller

    Follow the manufacturer's instructions to program the controller settings according to your specific application needs.

  6. Calibrate the system

    Perform any necessary calibration procedures as outlined in the user manual to ensure optimal performance of the controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.