Contact for Pricing
Overview
- 2000VA capacity, 120V input
- 120 dB Common Mode, 60 dB Transverse Mode Noise Attenuation
- Galvanic Isolation
- UL/CANADA certified (UL 1012, CSA)
- 4 NEMA 5-15R receptacles, 1 L5-30R receptacle, 1 L5-30 plug
Specifications
Application | Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment |
Brand Name | SolaHD |
Connector | (4) 5-R & (1) L5-30R Receptacles |
Frequency Rating | 60 HZ |
Height | 17 IN |
Input | 120, 208, 240, 480 |
Length | 9 IN |
Mounting | Bracket |
Noise Level | 35 to 65 dBA |
Output Power | 120, 208, 240 |
Special Features | +/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode |
Standard | UL, UL 1012, CSA, CE, ANSI/IEEE C62.41 |
Style | 1 |
Type | MCR Hardwired Series Power Line Conditioning with Voltage Regulation |
Width | 13 IN |
Package Dimensions (L x W x H) | 26 IN x 14 IN x 16 IN |
Package Dimensions (L x W x H) | 66.04 cm x 35.56 cm x 40.64 cm |
Package Weight (Imperial) | 111.000 L |
Package Weight (Metric) | 50.350 kg |

63-13-230-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
63-13-215-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
63-13-210-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
63-13-175-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:750VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
63-13-115-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:150VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
63-23-250-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
63-23-230-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
63-32-230-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage:600, Output Voltage: 120/208/240
63-29-250-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240
63-28-275-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240
63-32-220-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage:600, Output Voltage: 120/208/240
63-13-125-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:250VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P PlugFrequently Asked Questions
What is the VA rating and input voltage for model 63-13-220-6?
Model 63-13-220-6 has a 2000 VA rating and operates with a 120V input/output voltage.
What are the physical dimensions of the 63-13-220-6 unit?
The unit measures 11.00 in in height, 11.00 in in width, and 17.00 in in depth.
What types of receptacles and plug does model 63-13-220-6 have?
It features four 5-15R receptacles and one L5-30R receptacle, with an L5-30P plug.
Is maintenance required for the SolaHD MCR Series?
No, the SolaHD MCR Series units are designed to be maintenance-free.
What is the warranty period for this product?
The product comes with a 10 + 2 year limited warranty.
What is the output voltage regulation of the MCR Series?
The MCR Series provides ±3% output voltage regulation for 60 Hz units when the input voltage is between 80% and 110% of nominal.
What noise attenuation capabilities does this product offer?
It offers 120 dB common mode and 60 dB transverse mode noise attenuation.
Does the SolaHD MCR Series provide surge protection?
Yes, it provides surge protection tested to ANSI/IEEE C62.41 Class A & B waveform, with a let-through voltage typically less than 10 V.
What is the operating temperature range for the unit?
The operating temperature range is -20°C to 40°C, with humidity less than 95% non-condensing.
What is the typical efficiency of the unit at full load?
The typical efficiency of the unit at full load is 92%.
Frequently Asked Questions about SolaHD
What certifications and standards do SolaHD products comply with?
SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.
What industries and applications are SolaHD products used for?
SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.
What technical support does SolaHD offer?
SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.
What are the main product lines offered by SolaHD?
SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.
What are the key features of SolaHD products?
SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.
What environmental ratings do SolaHD products have?
SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What accessories are available for SolaHD products?
SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.
How are SolaHD products typically installed?
SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.