Authorized SolaHD Distributor
SolaHD 63-13-215-6 - Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
SolaHD

63-13-215-6

UPC: 783472561674


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD 63-13-215-6 is a 1500VA industrial power supply designed for critical applications requiring stable, clean power and superior noise suppression. Operating at 120 VAC, this unit delivers a robust 12.5 A current rating, making it suitable for powering motors, control panels, and other heavy-duty industrial equipment. Its advanced noise attenuation capabilities include 120 dB of common-mode noise reduction and 60 dB of transverse-mode noise reduction, effectively minimizing electromagnetic interference (EMI) and ensuring signal integrity for sensitive electronics. Galvanic isolation is a key feature, providing a crucial layer of protection against voltage spikes, ground loops, and electrical faults, thereby enhancing the safety of both personnel and connected equipment. Compliance with stringent industry standards is assured, as the SolaHD 63-13-215-6 is certified to UL 1012 and CSA (Canada and US). Installation is straightforward in standard industrial settings, thanks to its configuration of six NEMA 5-15R receptacles and one NEMA 5-15P plug. Ideal for manufacturing lines, HVAC systems, automation, and any environment where reliable, low-noise power is paramount, this SolaHD power supply combines durability, safety, and performance in a compact and easy-to-install package. Its 60 Hz frequency ensures compatibility with standard North American power grids.
  • 1500VA power capacity at 120V input
  • 120 dB common-mode and 60 dB transverse-mode noise attenuation
  • Galvanic isolation for protection against voltage spikes and ground loops
  • UL 1012 and CSA certified for North American safety standards
  • Six NEMA 5-15R receptacles and one NEMA 5-15P plug for flexible connectivity

Specifications

Application
Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment
Brand Name
SolaHD
Connector
(4) 5-R & (1) L5-30R Receptacles
Frequency Rating
60 HZ
Height
17 IN
Input
120, 208, 240, 480
Length
7 IN
Mounting
Bracket
Noise Level
35 to 65 dBA
Output Power
120, 208, 240
Special Features
+/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode
Standard
UL, UL 1012, CSA, CE, ANSI/IEEE C62.41
Style
1
Type
MCR Hardwired Series Power Line Conditioning with Voltage Regulation
Width
9 IN
Package Dimensions (L x W x H)
16.5 IN x 25.5 IN x 21 IN
Package Dimensions (L x W x H)
41.91 cm x 64.77 cm x 53.34 cm
Package Weight (Imperial)
111.000 L
Package Weight (Metric)
50.350 kg
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-210-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-612-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-720-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (240 V Delta)

STF0150-24D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (240 V Delta)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0 2, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (240 V Delta)

STF2000-24D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0 2, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (240 V Delta)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 30.0, Minimum Wire Size AWG 10, Fuse/Circuit Breaker Ampacity: Suggested 30A, Maximum 37.5A, Three Phase (240 V Delta)

STF0300-24D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 30.0, Minimum Wire Size AWG 10, Fuse/Circuit Breaker Ampacity: Suggested 30A, Maximum 37.5A, Three Phase (240 V Delta)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (120.208 Vac wye)

STF0150-10Y

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (120.208 Vac wye)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 50.0, Minimum Wire Size AWG 4, Fuse/Circuit Breaker Ampacity: Suggested 50A, Maximum 62.5A, Three Phase (240 V Delta)

STF0500-24D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 50.0, Minimum Wire Size AWG 4, Fuse/Circuit Breaker Ampacity: Suggested 50A, Maximum 62.5A, Three Phase (240 V Delta)

Frequently Asked Questions

What is the input/output voltage for this model?

Product 63-13-215-6 operates with a nominal input and output voltage of 120V.

What are the physical dimensions of the 63-13-215-6?

The unit measures 11.00 in in height, 11.00 in in width, and 17.00 in in depth.

What is the shipping weight of the 63-13-215-6?

The shipping weight for model 63-13-215-6 is 95.0 lbs (43.09 kg).

What type of receptacles and plug does it have?

Model 63-13-215-6 features six 5-15R receptacles and a 5-20P plug.

Does this product require any maintenance?

No, the SolaHD MCR Series, including this model, requires no maintenance.

What certifications does the 1500 VA unit hold?

The 1500 VA units are RoHS Compliant, UL 1012 Listed, CSA C22.2 No. 66 Listed, and cULus certified.

What is the typical Mean Time Between Failure (MTBF)?

The typical Mean Time Between Failure (MTBF) for this series is 25 years.

What is the noise attenuation capability?

The unit offers 120 dB common mode and 60 dB transverse mode noise attenuation.

What is the output voltage regulation of the unit?

The unit provides ±3% output voltage regulation for 60 Hz units when the input voltage is between 80% and 110% of nominal.

What is the operating temperature range?

The operating temperature range for the unit is -20°C to 40°C, with humidity less than 95% non-condensing.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.