Authorized SolaHD Distributor
SolaHD 63-13-115-6 - Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:150VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

SolaHD 63-13-115-6 Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic…

UPC: 783472561476


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The SolaHD 63-13-115-6 power conditioner delivers industrial-grade power conditioning for sensitive electronic equipment. Rated at 150VA with a 120V input, this unit provides clean, stable power to protect downstream devices from electrical noise and transients. It features 120 dB of common-mode noise attenuation and 60 dB of transverse-mode attenuation, effectively suppressing interference that can disrupt control systems, data acquisition, and precision instrumentation. Galvanic isolation between input and output prevents ground loops and electrical faults, enhancing system safety and reliability. Certified to UL 1012 and CSA standards for use in both Canada and the United States, the 63-13-115-6 meets stringent safety and performance requirements. The unit includes four NEMA 5-15R receptacles for connecting multiple devices and a single NEMA 5-15P plug for input power. This configuration supports flexible deployment in industrial control rooms, data centers, laboratories, and manufacturing environments where clean power is critical. Designed for applications requiring stable voltage and minimal electrical interference, the SolaHD 63-13-115-6 is ideal for protecting PLCs, sensors, communication equipment, and other sensitive electronics. Its compact form factor and standard NEMA-rated connectors simplify integration into existing systems. With no moving parts and a focus on noise suppression, this power conditioner ensures consistent performance in high-precision operations.
  • 150VA power capacity
  • 120V input voltage
  • 120 dB common mode noise attenuation
  • 60 dB transverse mode noise attenuation
  • Galvanic isolation for enhanced safety
  • Four NEMA 5-15R receptacles and one NEMA 5-15P plug
  • UL (Canada and US) and CSA certified to UL 1012

Specifications

Application
Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment
Brand Name
SolaHD
Connector
(4) 5-R Receptacles
Frequency Rating
60 HZ
Height
9 IN
Input
120, 208, 240, 480
Length
5 IN
Mounting
Bracket
Nema Rating
NEMA 5-15R/NEMA 5-15P
Noise Level
35 to 65 dBA
Output Power
120
Special Features
+/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode
Standard
RoHS Compliant, UL Listed: UL 1012, cULus Listed: (1500VA Units) UL 1012, CSA C22.2 No. 66; CSA Certified: (70VA-1kVA Units), CSA C22.2 No. 66
Style
1
Type
MCR Hardwired Series Power Line Conditioning with Voltage Regulation
Voltage Rating
120 V
Width
4 IN
Package Dimensions (L x W x H)
14.9 IN x 9.1 IN x 12.7 IN
Package Dimensions (L x W x H)
37.846 cm x 23.114 cm x 32.258 cm
Package Weight (Imperial)
18.400 L
Package Weight (Metric)
8.346 kg
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:750VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-175-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:750VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-210-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:250VA, Input Voltage: 120/208/240/480, Output Voltage: 120

63-23-125-4

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:250VA, Input Voltage: 120/208/240/480, Output Voltage: 120
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:21000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-220-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:21000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug

63-13-230-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-210-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-215-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:2000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug

63-13-220-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:2000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug

Frequently Asked Questions

What is the VA rating of product 63-13-115-6?

The SolaHD 63-13-115-6 has a VA rating of 150 VA.

What is the input/output voltage for model 63-13-115-6?

The input and output voltage for model 63-13-115-6 is 120 V.

What are the dimensions of the 63-13-115-6 unit?

The unit measures 6.00 in height, 7.00 in width, and 9.00 in depth.

What type of receptacles does the 63-13-115-6 have?

The 63-13-115-6 unit is equipped with four 5-15R receptacles.

What type of plug does the 63-13-115-6 use?

The 63-13-115-6 unit uses a 5-15P plug.

Does the SolaHD MCR Series require maintenance?

No, the SolaHD MCR Series units, including this model, require no maintenance.

What noise attenuation does the MCR Series offer?

The MCR Series offers 120 dB common mode and 60 dB transverse mode noise attenuation.

What is the operating temperature range for this product?

The operating temperature range for 70-1000 VA, 60 Hz portable models is -20°C to +40°C.

What certifications does the 63-13-115-6 model have?

This 150 VA unit is RoHS Compliant, UL 1012 Listed, and CSA C22.2 No. 66 Certified.

What is the typical Mean Time Between Failure (MTBF)?

The typical Mean Time Between Failure (MTBF) for these units is 25 years.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.