Authorized SolaHD Distributor
SolaHD 63-32-220-8 - Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage:600, Output Voltage: 120/208/240
SolaHD

63-32-220-8

UPC: 783472136100


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD 63-32-220-8 is a robust 2000VA isolation transformer designed for industrial applications requiring high voltage isolation and superior noise attenuation. With a voltage rating of 120/208/240 V, it easily integrates into existing power distribution systems in both North American and Canadian facilities. The transformer delivers an impressive 120 DB common‑mode noise reduction and 60 DB transverse‑mode attenuation, ensuring clean, interference‑free operation for sensitive equipment. It features galvanic isolation to protect downstream circuits from voltage spikes and surges, and is UL (CANADA AND US), UL 1012, CSA, and ANSI/IEEE C62.41 certified, meeting stringent safety and reliability standards. Whether used in data centers, manufacturing lines, or industrial control rooms, the SolaHD 63-32-220-8 provides reliable performance, energy efficiency, and long service life. Its rugged construction and compliance with major safety standards make it a dependable choice for critical infrastructure, while its compact design allows for easy installation in tight spaces. Choose SolaHD for a transformer that combines high capacity, superior noise suppression, and certified safety for demanding industrial environments.
  • 2000VA power rating
  • 120/208/240 V voltage compatibility
  • 120 DB common‑mode noise attenuation
  • 60 DB transverse‑mode noise reduction
  • Galvanic isolation with UL/CSA certification

Specifications

Application
Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment
Brand Name
SolaHD
Frequency Rating
60 HZ
Height
17 IN
Input
600 VAC
Length
7 IN
Mounting
Bracket
Noise Level
35 to 65 dBA
Output Power
120, 208, 240 VAC
Special Features
+/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode
Standard
cULus Listed: (500VA-3kVA Units) UL 1012, CSA C22.2 No. 66; CSA Certified (5kVA-15kVA Units) CSA C22.2 No. 66, RoHS Compliant
Style
1
Type
MCR Hardwired Series Power Line Conditioning with Voltage Regulation
Width
9 IN
Package Dimensions (L x W x H)
24 IN x 14 IN x 16 IN
Package Dimensions (L x W x H)
60.96 cm x 35.56 cm x 40.64 cm
Package Weight (Imperial)
108.000 L
Package Weight (Metric)
48.989 kg
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-215-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240

63-29-275-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240

63-28-275-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240

63-29-250-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US, UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240

63-29-310-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US, UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240

63-29-315-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-250-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-230-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

Frequently Asked Questions

Can this unit act as a step-up or step-down transformer?

Yes, the MCR Hardwired Series can act as both a step-up or step-down transformer.

What is the warranty period for this product?

The product comes with a 10 + 2 year limited warranty.

What is the recommended minimum load for the unit?

It is recommended that the unit run at a minimum of 40-50% load.

What certifications does the 63-32-220-8 have?

The 63-32-220-8 is UL 1012 and CSA C22.2 No. 107.1 listed, and RoHS compliant.

Is maintenance required for the SolaHD MCR series?

No, the SolaHD MCR Hardwired Series requires no maintenance.

What is the storage temperature range for the unit?

The storage temperature range is -20° to +85°C with humidity less than 95% non-condensing.

What is the operating temperature range for the unit?

The operating temperature range is -20° to 50°C with humidity less than 95% non-condensing.

Does the 63-32-220-8 provide surge protection?

Yes, it provides surge protection with less than 10V let-through, tested to ANSI/IEEE C62.41 Class A & B Waveform.

What noise attenuation capabilities does this product offer?

It offers 120 dB common mode and 60 dB transverse mode noise attenuation.

What is the output voltage regulation for 63-32-220-8?

The 63-32-220-8, being a 60 Hz unit, provides ±3% output voltage regulation.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.