Overview
- 5000VA power rating for medium to large industrial loads
- 120 dB common-mode and 60 dB transverse-mode noise attenuation
- Galvanic isolation for electrical safety and fault protection
- Input voltage range: 120/208/240/480 VAC, Output: 120/208/240 VAC
- Compatible with PLCs, motor drives, and control systems
Specifications
Application | Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment |
Brand Name | SolaHD |
Connection Type | Not explicitly stated |
Current Rating | 5000 VA |
Frequency | 50/60 Hz |
Frequency | Not explicitly stated |
Frequency Rating | 60 HZ |
Height | 19 IN |
Input | 120, 208, 240, 480 |
Length | 9 IN |
Material | Not explicitly stated |
Mounting | Bracket |
Mounting Type | Not explicitly stated |
Noise Level | 35 to 65 dBA |
Output Power | 120, 208, 240 |
Phase | 1 |
Poles | Not explicitly stated |
Primary Voltage | 120/208/240/480 |
Regulation | +/-3 |
Secondary Voltage | 120/208/240 VAC |
Series | 63-23 |
Series | 63-23-250-8 |
Series | 63-23-250 |
Special Features | +/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode |
Standard | UL, UL 1012, CSA, CE, ANSI/IEEE C62.41 |
Style | 1 |
Type | MCR Hardwired Series Power Line Conditioning with Voltage Regulation |
Voltage Rating | 120/208/240/480 VAC (Input), 120/208/240 VAC (Output) |
Voltage Rating | 120/208/240/480 VAC Input / 120/208/240 VAC Output |
Voltage Rating | Input: 120/208/240/480 VAC, Output: 120/208/240 VAC |
Wattage | 5000 VA |
Width | 13 IN |
Package Dimensions (L x W x H) | 17 IN x 34 IN x 16.5 IN |
Package Dimensions (L x W x H) | 43.18 cm x 86.36 cm x 41.91 cm |
Package Weight (Imperial) | 217.000 L |
Package Weight (Metric) | 98.431 kg |

63-28-275-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240
63-23-230-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
63-23-710-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
63-23-730-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
63-23-750-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
63-28-775-8
MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240
63-28-810-8
MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240
63-28-815-8
MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240Frequently Asked Questions
What is the output voltage regulation for 60 Hz MCR series units?
The output voltage regulation for 60 Hz MCR series units is ±3%. For 50 Hz units, it is ±5%.
What is the noise attenuation for the SolaHD MCR Hardwired Series?
The noise attenuation is 120 dB for common mode and 60 dB for transverse mode.
What surge protection is offered by the MCR series?
Surge protection is tested to ANSI/IEEE C62.41 Class A & B Waveform with less than 10 V let through typical.
What are the operating temperature and storage temperature limits?
The operating temperature is -20° to 50°C, and the storage temperature is -20° to 85°C.
What is the typical Mean Time Between Failure (MTBF) for the MCR series?
The MCR series has a typical MTBF of 25 years.
Does the MCR series require maintenance?
No, the MCR series requires no maintenance.
What is the maximum output harmonic distortion for the MCR series?
The output harmonic distortion is 3% total RMS content at full load within the input range.
What is the overload protection setting for the MCR series?
The overload protection is current limited at 1.65 times the rated current at nominal input voltage.
What is the input voltage range for continuous operation at full load?
The input voltage range for continuous operation at full load is +10% to -20% of nominal.
What is the input voltage tolerance for temporary surges or sags?
For temporary surge or sags, the input voltage tolerance is +20% to -35% of nominal.
Frequently Asked Questions about SolaHD
What certifications and standards do SolaHD products comply with?
SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.
What industries and applications are SolaHD products used for?
SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.
What technical support does SolaHD offer?
SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.
What are the main product lines offered by SolaHD?
SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.
What are the key features of SolaHD products?
SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.
What environmental ratings do SolaHD products have?
SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What accessories are available for SolaHD products?
SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.
How are SolaHD products typically installed?
SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.