Contact for Pricing
Overview
- 24" x 24" mild steel enclosure for industrial switches
- Includes 8 Cat 6A STP copper patch cords and Mini-Com modules
- Features 2 MM LC fiber patch cords with 6 LC adaptors
- Integrated backplane and cable management included
- Pre-configured for rapid deployment
Specifications
Application | Industrial Automation |
Color | Gray |
Depth | 11.6 In. |
Material | Mild Steel |
Mounting | Wall mount |
Standard | UL 508A Standard for Industrial Control Panels, UL Type 4/12 or 4X, IP66 Rated, RoHS Compliant |
Type | Pre-Configured Network Zone System Enclosure |
Width | 24 In. |
Package Dimensions (L x W x H) | 44 IN x 44 IN x 17 IN |
Package Weight (Imperial) | 170 lbs |

Z22U-S16
Universal Network Zone System, 24" x 24", mild steel enclosure, for one industrial switch, includes (8) Cat 6 UTP copper patch cords and jacks, (2) MM LC fiber uplink patch cords with (6) adaptors and redundant power supplies, battery UPS, PoE
Z23C-6
Pre-Configured Network Zone System, 24" x 36", 316 stainless steel enclosure, for two industrial switches, includes (16) Cat 6 UTP copper patch cords and jacks, (4) MM LC fiber patch cords with (6) adaptors, backplane and cable management. NEMA 4X/4/12, IP66
DIRLC25S23W
The air inlet duct directs cooling air from the cold aisle into the intake fans of switches. It fits in a 3 RU footprint and is designed for Cisco Catalyst 6880 switch.
CUEOR12CPW1
The Net-Contain End of Row Cap is part of the Universal Aisle Containment system for cold aisle or hot aisle contaiment in a floor-mounted structure compatible with most cabinet brands and sizes. The End of Row Cap is for 4-foot (1200mm) aisle widths. It is white.
FCP9PP-2323GG
The rack-mount fiber optic splitter tray fits in 19" racks, occupies 1 RU, and uses a planar lightwave circuit to split one signal to thirty-two signals for passive optical network applications. The splitter tray includes two SC-APC inputs and thirty-two SC-APC outputs on the front of the device.
DIRLC3210S17W
The air inlet duct directs cooling air from the cold aisle into the intake fans of switches. It requires 3 RU above the switch and 2 RU below the switch and is designed for Cisco Catalyst 6807-XL switch.
FCP9PP-2163GG
The rack-mount fiber optic splitter tray fits in 19" racks, occupies 1 RU, and uses a planar lightwave circuit to split one signal to sixteen signals for passive optical network applications. The splitter tray includes two SC-APC inputs and sixteen SC-APC outputs on the front of the device.Frequently Asked Questions
What are the dimensions of the Z23C-SS enclosure?
The Z23C-SS enclosure dimensions are 36.0 in. x 24.0 in. x 11.7 in. (914mm x 610mm x 297mm).
What is the maximum operating temperature?
The enclosure is validated to operate at a maximum temperature of 140°F (60°C).
What materials are used for the Z23C-SS enclosure?
The enclosure is made of gray 14 gauge cold roll steel or 316 stainless steel.
What safety features does the Z23C-SS include?
It includes an isolation barrier to segregate high voltage from lower voltage equipment for safety.
What standards does the Z23C-SS comply with?
The Z23C-SS complies with UL 508A, UL Type 4/12 or 4X, and is IP66 rated.
What is the humidity rating for the Z23C-SS?
The enclosure can operate at up to 95% non-condensing humidity.
How is the Z23C-SS mounted?
The Z23C-SS can be wall-mounted with an optional outside-mount flange.
What accessories are included with the Z23C-SS?
Included accessories are DIN rails, cable management components, and an isolation barrier.
What is the purpose of the removable back plate?
The removable back plate with DIN rails allows for rapid installation of components.
What type of power supply is required?
The Z23C-SS is designed for use in an EtherNet/IP zone architecture with a compatible power supply.
How to Install the Z22C-6S Network Zone System
This guide provides step-by-step instructions for installing and configuring the Z22C-6S Network Zone System, including mounting, wiring, and initial setup.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Ground wire
- Mount the enclosure
Drill holes 22.5 inches apart horizontally and 25.56 inches apart vertically on the wall. Secure the enclosure to the wall using 3/8-inch bolts and sealing washers, ensuring it is level and stable.
- Install the switch
Remove wires from terminal blocks and then remove the terminal blocks. Install the switch according to the manufacturer's instructions and the supplied Field Wiring Diagram.
- Wire the system
Connect the ground wire to the switch and ensure all connections are secure. Use a multimeter to verify that there are no short circuits before applying power.
- Configure the system
Follow the configuration instructions provided in the documentation to set up the network parameters and ensure proper operation of the Z22C-6S system.
- Calibrate the system
Perform any necessary calibration procedures as outlined in the documentation to ensure optimal performance of the Network Zone System.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.