Contact for Pricing
Overview
- Permanently mounted voltage tester for 3-phase AC systems up to 600V
- Performs absence of voltage test before panel opening to prevent electrical hazards
- Improves personnel safety and reduces operational downtime
- Includes 2' system cable, 3' sensor leads, and industrial lithium battery
- Robust design for industrial environments
Specifications
Application | For use in 1, 2 or 3-phase AC or DC systems |
Special Features | NA |
Standard | UL 1436, UL 508, CSA-C22.2 No. 14, CAN/CSA-C22 No.160, CAN/CSA-C22.2 No.107.1, IEC/UL/CSA C22.2 No. 61010-1, IEC/UL.CSA C22.2 No 61010-2-030, IEC 61508-1, -2 and -3 (SIL Rating) |
Type | Absence of Voltage Tester |
Voltage Rating | 600 V |
Package Dimensions (L x W x H) | 16.77 IN x 10.11 IN x 3.58 IN |
Package Weight (Imperial) | 2.86 lbs |

VS-AVT-C08-L10A
The VS-AVT-C08-L10A VeriSafe 1.0 Absence of Voltage Tester is a permanently mounted voltage tester for use in 3-phase AC systems up to 600 V. Activating VeriSafe performs an absence of voltage test before opening the panel, helping prevent possible exposure to electrical hazards, improving safety, and reducing downtime. This SKU includes a three-phase AVT tester equipped with 3.0m sensor leads, 2.4m system cable and an industrial lithium battery. Optimized for APAC markets.
VS-AVT-RKP1
The VS-AVT-RKP1 VeriSafe AVT Retrofit Kit is the complete kit to retrofit equipment with the VeriSafe Absence of Voltage Tester. Activating VeriSafe performs an absence of voltage test before opening the panel, helping prevent possible exposure to electrical hazards and improving safety. Kit includes AVT tester with 10ft. sensor leads, 8ft. system cable, VeriSafe Insulation Piercing Connection Kit 14-6 AWG power connectors, (12) cable ties, (6) cable ties mounts, (1) wire marker card.
VS-AVT-RKP2
The VS-AVT-RKP2 VeriSafe AVT Retrofit Kit is the complete kit to retrofit equipment with the VeriSafe Absence of Voltage Tester. Activating VeriSafe performs an absence of voltage test before opening the panel, helping prevent possible exposure to electrical hazards and improving safety. Kit includes AVT tester with 10ft. sensor leads, 8ft. system cable, VeriSafe Insulation Piercing Connection Kit 4- 3/0 AWG power connectors, (12) cable ties, (6) cable ties mounts, (1) wire marker card.
VS-AVT2-C02L03
VeriSafe Absence of Voltage Tester for Class 1 Division 2 hazardous locations - 2 ft. system cable, 3 ft. sensor leads.
VS-AVT2-C08L10
The VS-AVT2-C08L10 VeriSafe Absence of Voltage Tester is the first-of-its-kind voltage tester that determines the absence of voltage with just a push of a button for Class 1 Division 2 hazardous locations. Activating VeriSafe performs an absence of voltage test before opening the panel, helping prevent possible exposure to electrical hazards, improving safety, and reducing risk. Includes AVT tester equipped with 10' sensor leads, 8' system cable, and industrial Lithium battery.How to Install the VS-AVT-C02-L03 Absence of Voltage Tester
Install the VS-AVT-C02-L03 Absence of Voltage Tester (AVT) to verify a circuit is de-energized before opening an electrical enclosure.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter, Crimping tool (if using certain connectors)
Supplies needed:
Mounting screws (for Isolation Module if not using DIN rail), Wire connectors (rated for application), Terminal blocks or power distribution blocks (optional), Yellow Instruction Label
- Prepare the Installation Location
Identify all sources of electrical energy in the equipment. Determine the point in the circuit where you will normally test for voltage. Mark this location on the yellow Instruction Label and prepare to apply it to the outside of the enclosure near the Indicator Module after installation.
- Mount the Indicator Module
Mount the Indicator Module into a standard 30 mm knockout with a notch on the electrical enclosure. Ensure the notch is positioned at the top. The maximum panel thickness for mounting is 0.25 inches (6.35 mm).
- Mount the Isolation Module
Mount the Isolation Module. This can be done by securing it to a DIN rail using the integrated clip or by surface mounting it using screws. Ensure the module is securely fastened.
- Connect Sensor Lead Wires
Connect the sensor lead wires to the circuit conductors and the protective earth (ground). Each conductor (L1, L2, L3, and GND) should have at least one sensor lead set. Do not mechanically connect sensor leads of the same label designation to each other. Trim excess sensor lead length; do not extend with a splice. Use approved connection methods and follow local codes and standards. Ensure the AVT is solidly grounded and bonded to the protective conductor terminal of the enclosure.
- Connect the AVT System Cable
Connect the Indicator Module and the Isolation Module using the provided AVT System Cable. Ensure the AVT System Cable is separated from sensor leads and other circuits by a minimum of 0.25 inches (6 mm).
- Verify Installation and Functionality
Apply the yellow Instruction Label to the outside of the enclosure near the Indicator Module. Perform the commissioning checklist to verify the correct function of the device after installation. Refer to the 'Commissioning Checklist' section in the manual for detailed procedures.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.