Authorized Panduit Distributor
Panduit R4PATCWH - Seals the top of an R4P or R4P36 for containment, improving airflow management and thermal efficiency.It features an adjustable length to fit a 30" deep R4P or a 36" deep R4P36. Designed to be used withPR2V or PE2V top caps and PR2V/PE2V containment end panels to create a thermally contained solution

Panduit R4PATCWH Seals the top of an R4P or R4P36 for containment, improving airflow management and…

UPC: 613056900561


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetVideo Clip

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit R4PATCWH top seal is a precision-engineered accessory for R4P and R4P36 containment enclosures, designed to optimize thermal efficiency and airflow management in data center environments. This adjustable-length seal fits both 30" deep R4P and 36" deep R4P36 enclosures, ensuring a secure fit without custom fabrication. When paired with PR2V or PE2V top caps and PR2V/PE2V containment end panels, the R4PATCWH creates a fully contained thermal solution that minimizes hot-aisle/cold-aisle mixing. The seal’s design reduces cooling system workload by improving containment integrity, leading to measurable energy savings in high-density server deployments. Constructed from durable materials, it withstands continuous operation in data center conditions while maintaining dimensional stability. Installation requires no specialized tools, integrating seamlessly with Panduit’s containment ecosystem for rapid deployment. Ideal for retrofits or new builds, this seal is a cost-effective way to enhance existing containment systems without replacing infrastructure.
  • Adjustable length fits 30" deep R4P or 36" deep R4P36 enclosures
  • Compatible with PR2V or PE2V top caps and containment end panels
  • Enhances thermal containment to reduce cooling system workload
  • Durable construction for continuous data center operation
  • No specialized tools required for installation

Specifications

Color
White
Finish
Powder-coated
Length
36 in
Length
914.4 mm
Material
Steel
Standard
RoHS Compliant
Type
Rack Top Cap
Width
24.02 in
Width
610.108 mm
Package Dimensions (L x W x H)
37.625 IN x 24.8 IN x 1.625 IN
Package Dimensions (L x W x H)
95.5675 cm x 62.992 cm x 4.1275 cm
Package Weight (Imperial)
5.0000 L
Package Weight (Metric)
2.2680 kg
Seals the top of an AR4P for containment, improving airflow management and thermal efficiency.It features an adjustable length to fit an AR4P set at a 30" or 36" depth. Designed to be used with PR2V or PE2V top caps and PR2V/PE2V containment end panels to create a thermally contained solution

AR4PATCWH

Seals the top of an AR4P for containment, improving airflow management and thermal efficiency.It features an adjustable length to fit an AR4P set at a 30" or 36" depth. Designed to be used with PR2V or PE2V top caps and PR2V/PE2V containment end panels to create a thermally contained solution
15 inch Nylon beaded strap. Black.

S28612

15 inch Nylon beaded strap. Black.
Seals the top of an R4P or R4P36 for containment, improving airflow management and thermal efficiency.It features an adjustable length to fit a 30" deep R4P or a 36" deep R4P36. Designed to be used withPR2V or PE2V top caps and PR2V/PE2V containment end panels to create a thermally contained solution

R4PATC

Seals the top of an R4P or R4P36 for containment, improving airflow management and thermal efficiency.It features an adjustable length to fit a 30" deep R4P or a 36" deep R4P36. Designed to be used withPR2V or PE2V top caps and PR2V/PE2V containment end panels to create a thermally contained solution
Designed to enhance airflow containment by sealing gaps that form in the backbone of a 12" wide PE2V when blanking panels or network equipment is installed. Prevents bypass airflow, improving cooling efficiency and optimizing thermal management in data centers. Backbone panel ensures a secure fit, enhancing overall containment effectiveness while maintaining accessibility for cable maangement.

PE2V12BBP

Designed to enhance airflow containment by sealing gaps that form in the backbone of a 12" wide PE2V when blanking panels or network equipment is installed. Prevents bypass airflow, improving cooling efficiency and optimizing thermal management in data centers. Backbone panel ensures a secure fit, enhancing overall containment effectiveness while maintaining accessibility for cable maangement.
Designed to enhance airflow containment by sealing gaps that form in the backbone of a 10" wide PE2V when blanking panels or network equipment is installed. Prevents bypass airflow, improving cooling efficiency and optimizing thermal management in data centers. Backbone panel ensures a secure fit, enhancing overall containment effectiveness while maintaining accessibility for cable maangement.

PE2V10BBP

Designed to enhance airflow containment by sealing gaps that form in the backbone of a 10" wide PE2V when blanking panels or network equipment is installed. Prevents bypass airflow, improving cooling efficiency and optimizing thermal management in data centers. Backbone panel ensures a secure fit, enhancing overall containment effectiveness while maintaining accessibility for cable maangement.
Designed to enhance airflow containment by sealing gaps that form in the backbone of a 8" wide PE2V when blanking panels or network equipment is installed. Prevents bypass airflow, improving cooling efficiency and optimizing thermal management in data centers. Backbone panel ensures a secure fit, enhancing overall containment effectiveness while maintaining accessibility for cable maangement.

PE2V08BBP

Designed to enhance airflow containment by sealing gaps that form in the backbone of a 8" wide PE2V when blanking panels or network equipment is installed. Prevents bypass airflow, improving cooling efficiency and optimizing thermal management in data centers. Backbone panel ensures a secure fit, enhancing overall containment effectiveness while maintaining accessibility for cable maangement.
Designed to enhance airflow containment by sealing gaps that form in the backbone of a 6" wide PE2V when blanking panels or network equipment is installed. Prevents bypass airflow, improving cooling efficiency and optimizing thermal management in data centers. Backbone panel ensures a secure fit, enhancing overall containment effectiveness while maintaining accessibility for cable maangement.

PE2V06BBP

Designed to enhance airflow containment by sealing gaps that form in the backbone of a 6" wide PE2V when blanking panels or network equipment is installed. Prevents bypass airflow, improving cooling efficiency and optimizing thermal management in data centers. Backbone panel ensures a secure fit, enhancing overall containment effectiveness while maintaining accessibility for cable maangement.
Seals the top of a 12" PR2V for containment, improving airflow management and thermal efficiency. Top caps are reversable to be compatible with either 60% forward facing or 60% rear facing. Includes brushed pass through for sealed cable routing. It is adjustable to match the depth of a 30" deep R4P, a 36" deep R4P36 or an AR4P set at a 30" or 36" depth. Designed to be used with AR4P or R4P top caps and PR2V/PE2V containment end panels to create a thermally contained solution

PR2V12ATC

Seals the top of a 12" PR2V for containment, improving airflow management and thermal efficiency. Top caps are reversable to be compatible with either 60% forward facing or 60% rear facing. Includes brushed pass through for sealed cable routing. It is adjustable to match the depth of a 30" deep R4P, a 36" deep R4P36 or an AR4P set at a 30" or 36" depth. Designed to be used with AR4P or R4P top caps and PR2V/PE2V containment end panels to create a thermally contained solution

Frequently Asked Questions

What is the PatchRunner 2 cable manager made of?

It consists of a metal backbone with molded plastic cable management fingers.

What accessories can the cable manager accept?

It accepts 19 in. EIA accessories like patch panels, strain relief bars, blanking panels, and PDUs mounted vertically in a zero RU format.

Do the cable manager fingers provide bend radius control?

Yes, the molded plastic fingers provide integral bend radius control throughout their entire length.

Are the cable manager finger sections removable?

Yes, the finger sections of the cable manager are designed to be removable.

What type of door does the cable manager use?

The manager accepts a metal, hinged, push-to-close door that can open to either the right or left.

Does the manager require horizontal cable managers?

No, the vertical panel can manage all cables on the rack without needing horizontal cable managers.

How do I order a white cable manager?

To order a white cable manager, add "WH" to the end of the part number.

Does this manager save space in high-density environments?

Yes, its depth and integral Zero RU patching save up to half the space compared to traditional cabling management systems.

What safety standards does the manager meet?

The PatchRunner 2 cable manager meets UL 2416 and CSA C22.2 standards.

What is the depth of the cable manager?

The cable manager has an extra deep 26.8 in. depth, providing high capacity for switches and Category 6A cabling.

How to Install the R4PATCWH Vertical Cable Manager

This guide provides step-by-step instructions for installing the R4PATCWH Vertical Cable Manager on a 4-post rack, ensuring proper alignment and secure attachment.

Estimated time: 45m

Tools needed:

Ratchet with M8, M10 & M17 socket, Screwdriver, Wire strippers

Supplies needed:

M5 flange nuts, M10 serrated flange bolts, M10 flange nuts, M6 screws, Push-in rivets, Mounting screws

  1. Prepare the Rack

    Align the holes for the Top Panel with the rack top angle bracket and secure in place using M8 nuts and bolts.

  2. Install the Bottom Panel

    Align the Bottom Panel with the designated holes and install (4) #6 self-drilling screws. Do not tighten yet.

  3. Secure the Bottom Panel

    Move the Bottom Panel to the up-most forward position and tighten the #6 self-drilling screws to secure it firmly.

  4. Attach the Vertical Cable Manager

    Place the Vertical Cable Manager in the correct orientation and secure it using (3) M10 serrated flange bolts and (3) M10 serrated flange nuts.

  5. Install Backbone Panels

    Place Backbone panels on both sides of the manager and secure them using (2) provided push-in rivets per side.

  6. Install the VCM Top Cap

    Position the VCM Top Cap with the brush entry oriented as desired and secure it to the front of the VCM using the 5/16" screw and the rear closing clip to the rack using the M10 bolt and nut.

  7. Calibrate and Verify Installation

    Ensure all components are securely fastened and verify the alignment of the Vertical Cable Manager with the rack.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.