Contact for Pricing
Overview
- 432-pair (108-port) Category 6 termination kit
- High-density design for space efficiency
- Includes sturdy legs for stable placement
- Facilitates efficient field installations
- Ensures reliable data transmission
Specifications
Color | Beige |
Connection Type | Punchdown |
Depth | 3.35 In. |
Material | Polycarbonate |
Material | Poly |
Model | Base with Legs |
Mounting Type | Field Termination with Legs |
Series | Category 6 |
Size | 432-pair (108-port) |
Standard | Exceeds all channel and component requirements of ANSI/TIA-568.2-D Category 6 standard, Standard density exceeds all channel requirements of ANSI/TIA-568.2-D Category 6A standard, Meets IEC 60352-4 requirements; can withstand repeated terminations up to 2 |
Type | High Density Termination Kit |
Width | 10.67 In. |
Package Dimensions (L x W x H) | 12.5 IN x 10.8 IN x 0.1 IN |
Package Weight (Imperial) | 2.84 lbs |

P110B100R2Y
The Two 100 Pair 110 Punchdown Bases Pre-Mounted To 19 Rack Mount Panel is for use with Pan-Punch 110-style Bases, Connectors and Systems.Frequently Asked Questions
Is calibration recommended before testing?
Yes, it is STRONGLY RECOMMENDED that the tester is calibrated prior to testing.
What is the recommended software version for Fluke testers?
The recommended software version for Fluke testers is V2.24 or later for the firmware and V6.0 or later for Linkware Software.
What is the recommended software version for Agilent testers?
The recommended software version for Agilent testers is 4.0.9 or later for both WireScope Pro Software and ScopeData Pro II.
Where can I find the latest firmware for Fluke testers?
The latest firmware for Fluke testers can be found on the Fluke Networks website.
Where can I find the latest firmware for Agilent testers?
The latest firmware for Agilent testers can be found on the Agilent Technologies website.
What should be done if using a different DualRemote?
The tester must be recalibrated if using a different DualRemote or upgrading the software.
What is the part number for the Cat6A Permanent Link Adapter?
The part number for the Cat6A Permanent Link Adapter is DTX PLA002.
What is the part number for the Cat6A Channel Adapter?
The part number for the Cat6A Channel Adapter is DTX-CHA001A.
What is the part number for Agilent's Universal Cat6A Link SmartProbes?
The part number for Agilent's Universal Cat6A Link SmartProbes is N2644A-101.
What is the part number for Agilent's Universal Cat6A Channel SmartProbe?
The part number for Agilent's Universal Cat6A Channel SmartProbe is N2644A-100.
How to Install the GPKBW432Y Punchdown System
This guide provides step-by-step instructions for installing and configuring the GPKBW432Y Punchdown System for efficient wiring management.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter, Punchdown tool
Supplies needed:
Mounting screws, Terminal connectors, Cable identification labels
- Mount the base
Use appropriate mounting hardware to install the base on a sturdy surface, ideally 68 inches from the floor for optimal height. Ensure the Panduit lettering is upright.
- Route the cables
Carefully route the cables through the designated slots in the base, ensuring that the cable jacket end is within 1/2 inch from where the cable pairs will be inserted.
- Prepare cable pairs
Strip back the cable jacket only as required for termination, maintaining the twists of the pairs up to the point of connection. Inspect the color placement of the cable pairs before proceeding.
- Terminate the wires
Using a punchdown tool, secure the cable pairs into the connecting block, ensuring the tool is perpendicular to the base for a proper termination.
- Install cross-connect wires
If cross-connecting, terminate the wires to the top of the connecting blocks or install GP6 PLUS patch cords as needed, referencing the wiring scheme for color placement.
- Label the installation
Add cable identification to the label, fold it, and slide it into the label holder. Snap the label holder into position on the base between the rows of connecting blocks.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.