Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*
Overview
- Pre-polished LC-APC connector for singlemode 9/125µm OS2 fiber
- Field termination in ~2 minutes using standard fusion splice machines
- Compatible with 250µm loose-tube fiber with 900µm build-up tubing
- Meets ISO/IEC 11801, ANSI/TIA-568.3-D, and IA/EIA-604 standards
- RoHS-compliant with corrosion-resistant materials for harsh environments
Specifications
Boot Color* | Green |
Color | Green |
Connection | Fusion Splice |
Fiber Type | OS2 |
Insertion Loss | 0.3 dB |
Temperature Rating, Maximum | 108 F |
Temperature Rating, Maximum | 42.2222 C |
Temperature Rating, Minimum | 108 F |
Temperature Rating, Minimum | 42.2222 C |
Type | Fusion Splice |
Package Dimensions (L x W x H) | 12 IN x 6 IN x 1.5 IN |
Package Weight (Imperial) | 0.166 lbs |

FSCSLT9SOCA9AG
The fusion splice SC-APC Fiber Optic Connector is a singlemode 9/125?m OS2 fiber connector, intended for 250um loose-tube fiber with 900-micron build-up tubing. Field termination can be done in about two minutes using common fusion splice machines (not sold by Panduit). The pre-polished fiber endface eliminates time-consuming field polishing, reducing installation costs. The LC connector has a green-colored front assembly, with a green- and grey-colored rear assembly/boot.
FLCSLT9SOCU9BU
The fusion splice LC Fiber Optic Connector is a singlemode 9/125?m OS2 fiber connector, intended for 250um loose-tube fiber with 900-micron build-up tubing. Field termination can be done in about two minutes using common fusion splice machines (not sold by Panduit). The pre-polished fiber endface eliminates time-consuming field polishing, reducing installation costs. The LC connector has a blue-colored front assembly, with a blue- and grey-colored rear assembly/boot.
FSOCLCX
The OmniSplice LC-PC Fiber Optic Connector is a multimode 50/125?m OM3/OM4 simplex fiber connector. Termination can be done in about two minutes on several common splice machine brands. The connector consists of a ferrule assembly with a bare fiber stub, a black front housing, a rear housing with integral aqua boot, and a splice protection sleeve.
FSOCLCA
The OmniSplice LC-APC Fiber Optic Connector is a singlemode 9/125?m OS2 simplex fiber connector. Termination can be done in about two minutes on several common splice machine brands. The connector consists of a ferrule assembly with a bare fiber stub, a green front housing, a rear housing with integral green boot, and a splice protection sleeve.
FSOCLC9
The OmniSplice LC-UPC Fiber Optic Connector is a singlemode 9/125?m OS2 simplex fiber connector. Termination can be done in about two minutes on several common splice machine brands. The connector consists of a ferrule assembly with a bare fiber stub, a blue front housing, a rear housing with integral blue boot, and a splice protection sleeve.
FSOCSC9
The OmniSplice SC-UPC Fiber Optic Connector is a singlemode 9/125?m OS2 simplex fiber connector. Termination can be done in about two minutes on several common splice machine brands. The connector consists of a ferrule assembly with a bare fiber stub, a blue front housing, a rear housing with integral blue boot, and a splice protection sleeve.
FSOCSCX
The OmniSplice SC-PC Fiber Optic Connector is a multimode 50/125?m OM3/OM4 simplex fiber connector. Termination can be done in about two minutes on several common splice machine brands. The connector consists of a ferrule assembly with a bare fiber stub, a black front housing, a rear housing with integral aqua boot, and a splice protection sleeve.
FSOCSCA
The OmniSplice SC-APC Fiber Optic Connector is a singlemode 9/125?m OS2 simplex fiber connector. Termination can be done in about two minutes on several common splice machine brands. The connector consists of a ferrule assembly with a bare fiber stub, a green front housing, a rear housing with integral green boot, and a splice protection sleeve.Frequently Asked Questions
What is the return loss for the FLCSLT9SOCA9AG connector?
The FLCSLT9SOCA9AG connector has a return loss greater than 65dB. This is specific to its APC polish for singlemode fiber.
What is the insertion loss for the FLCSLT9SOCA9AG connector?
The FLCSLT9SOCA9AG connector has an average insertion loss of 0.15dB. The maximum insertion loss for singlemode fiber is 0.30dB.
What fiber types are compatible with this connector?
This connector is compatible with 9/125μm Singlemode fiber for OS1/OS2 applications. It uses 250μm coated fiber with a 900μm build-up tube.
What is the connector type for FLCSLT9SOCA9AG?
The FLCSLT9SOCA9AG is a Simplex LC connector with an APC polish. It is green in color and designed for 9/125μm OS1/OS2 fiber.
What fiber types are compatible with this connector?
This connector is compatible with 9/125μm Singlemode fiber for OS1/OS2 applications. It uses 250μm coated fiber with a 900μm build-up tube.
What is the connector type for FLCSLT9SOCA9AG?
The FLCSLT9SOCA9AG is a Simplex LC connector with an APC polish. It is green in color and designed for 9/125μm OS1/OS2 fiber.
What is the return loss for the FLCSLT9SOCA9AG connector?
The FLCSLT9SOCA9AG connector has a return loss greater than 65dB. This is specific to its APC polish for singlemode fiber.
What is the insertion loss for the FLCSLT9SOCA9AG connector?
The FLCSLT9SOCA9AG connector has an average insertion loss of 0.15dB. The maximum insertion loss for singlemode fiber is 0.30dB.
Do these connectors require index-matching gel?
No, the factory pre-polished end-faces mean no index-matching gel is needed for installation.
What is the length of the splice protection sleeve?
The LT9 style connectors, including FLCSLT9SOCA9AG, have a 1.5-inch splice protection sleeve.
How to Install the Panduit Fusion-Splice Connectors
This guide provides step-by-step instructions for installing Panduit Fusion-Splice Connectors for loose tube fiber with a 900μm build-up.
Estimated time: 1h
Tools needed:
Screwdriver, Fiber cleaver, Multimeter
Supplies needed:
Fusion-splice connectors, Build-up tubing, Splice protection sleeves, Lint-free wipes, Fiber cleaning solution
- Prepare the fiber
Strip at least 45 inches (115cm) of the outer jacket from the fiber and remove any aramid. Ensure there is approximately 1 inch (3cm) of inner jacket to encapsulate in the fanout kit.
- Clean the fiber
Clean the bare fiber with lint-free wipes and fiber cleaning solution, following proper safety precautions necessary when dealing with bare optical fiber.
- Cleave the fiber
Cleave the bare fiber to a length of 10mm using a fiber cleaver.
- Assemble the connector
Place the connector rear housing and boot assembly onto the field fiber, then slide the splice protection sleeve onto the field fiber.
- Insert the fiber into the splice machine
Place the cleaved fiber into the left-side fiber holder of the splice machine according to the specific instructions for your machine.
- Initiate the splice process
Close the wind cover of the splice stage and start the splice process as per your machine's instructions.
- Complete the splice
After the splice is completed, gently slide the splice protection sleeve up to the rear of the fiber holder and open both holders.
- Heat the splice
Place the splice point in the heater of the splice machine and close the heater cover. Follow the on-screen instructions for the heating and cooling process.
- Final assembly
Once the heating cycle is complete, snap the front housing together with the rear housing, ensuring the red alignment dot on top of the connector assembly faces up for APC connectors.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.