Overview
- Multimode 50/125µm OM3/OM4 simplex fiber connector
- Rapid termination in approximately 2 minutes
- Compatible with common splice machine brands
- Includes ferrule assembly, front/rear housing, integral aqua boot, and splice protection sleeve
- LC-PC polish for low insertion loss and high return loss
Specifications
Boot Color* | Aqua |
Color | Black, Aqua |
Color | Black |
Connection | Fusion Splice |
Connection Type | LC-PC |
Connection Type | LC-PC Fiber Optic Connector |
Connection Type | LC-PC Fiber Optic |
Fiber Type | OM3/OM4/OM5 |
Insertion Loss | 0.25 |
Material | Ceramic (Ferrule), Plastic (Housings) |
Material | Fiber Optic Connector (LC-PC) |
Material | Ceramic (Ferrule), Plastic (Housing) |
Material | Ferrule assembly, Fiber (50/125µm OM3/OM4), PVC |
Material | Fiber Optic Components |
Material | Fiber Optic Components (Ferrule, Housing, Boot) |
Series | OmniSplice |
Size | 50/125µm |
Size | 50/125µm OM3/OM4 simplex |
Temperature Rating, Maximum | 167 F |
Temperature Rating, Maximum | 75 C |
Temperature Rating, Minimum | 167 F |
Temperature Rating, Minimum | 75 C |
Package Dimensions (L x W x H) | 12.5 IN x 9 IN x 10.1 IN |
Package Dimensions (L x W x H) | 31.75 cm x 22.86 cm x 25.654 cm |
Package Weight (Imperial) | 19.9200 L |
Package Weight (Metric) | 9.0357 kg |

FLCSMCXGVL
The OptiCam Keyed LC Fiber Optic Connector is a multimode 50/125?m OM3/OM4/OM5 simplex fiber connector, intended for 900-micron tight-buffered fiber installation. The connector is keyed (Keyed G, Violet) for network security when used with other Keyed LC products. The LC connector has a natural-colored body with a violet-colored backbone and aqua 900?m boot.Frequently Asked Questions
What fiber types are compatible with FSOCLCX connectors?
FSOCLCX connectors are compatible with 50/125μm Multimode fiber for OM2, OM3, and OM4 applications.
What is the operating temperature range for these connectors?
The OmniSplice connectors have a functional temperature range from -40°C to 75°C.
What is the average insertion loss for multimode FSOCLCX?
For multimode fiber, the average insertion loss is 0.10dB, with a maximum of 0.25dB.
What is the minimum return loss for multimode FSOCLCX?
For multimode fiber (UPC), the return loss is greater than 30dB.
Which fusion splice brands are compatible with the OmniSplice holder?
The OmniSplice holder is compatible with common fusion splice brands like AFL (Fujikura), Fiber Fox, Sumitomo, and UCL Swift.
How long does it take to install an OmniSplice LC connector?
LC splice-on connectors can be terminated in an average of about two minutes per connector.
What type of ferrule do OmniSplice connectors use?
OmniSplice connectors utilize a factory polished zirconia ceramic ferrule.
What standards do OmniSplice connectors comply with?
They exceed Telcordia GR-326-CORE and ANSI/TIA-568.3-E, and comply with ANSI/TIA-604-10-D (LC) and 604-3-D (SC).
What are the dimensions of the OmniSplice LC Splice-On Connector?
The LC Splice-On Connector is 2.43 in long, 0.39 in wide, and 0.24 in high.
What fiber sizes and types are supported by OmniSplice connectors?
They support 900μm tight-buffered, 250μm loose-tube, and 250μm with 900μm build-up tubing.
How to Install the OmniSplice Fusion Splice Connector
This guide provides step-by-step instructions for installing the OmniSplice Fusion Splice Connector, ensuring proper handling and termination of optical fibers.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Splice protection sleeves, Handling sticks, Lint-free wipes, Fiber cleaning solution
- Open the connector package
Gently push the tray bottom tab down while lifting the tray lid tab up. Open the blister pack carefully and remove the connector assembly by the handling stick.
- Prepare the fiber
Mark and strip approximately 35mm of buffer and acrylate from the fiber. Clean the bare fiber with lint-free wipes and fiber cleaning solution, following safety precautions.
- Cleave the fiber
Cleave the bare fiber to 10mm. Ensure all acrylate coating has been removed for a successful cleave.
- Insert the fiber into the splice holder
Place the cleaved fiber into the left-side fiber holder according to the splice machine's instructions.
- Set up the OmniHolder
Place the OmniHolder on the right side of the splice stage. Ensure it is securely positioned.
- Insert the connector assembly
Place the connector assembly into the OmniHolder with the fiber stub protruding to the left and the handling stick protruding to the right.
- Start the splice process
Close the wind cover of the splice stage. Depending on the machine, the splice process may begin automatically or require pressing a start button.
- Complete the splice
After the splice is completed, wait for the machine to provide an estimated insertion loss value. Do not touch the fiber or connector assembly until the tension test is complete.
- Prepare for heating
Gently slide the splice protection sleeve up to the rear of the fiber holder and open the fiber holder.
- Lift the ferrule assembly
Press down on the holder lever to lift the ferrule assembly out of the OmniHolder for ease of handling.
- Position the splice point
Grasp the field fiber and raise the left side slightly to ensure the splice protection sleeve is flush against the connector subassembly.
- Heat the splice
Place the splice point in the heater of the splice machine, ensuring the splice protection sleeve is centered. Close the heater cover.
- Remove the assembly
Once the heating/cooling cycle is complete, carefully remove the assembly from the heating area and allow a 30-second cool time.
- Assemble the connector
Slide the rear assembly up, align the side tabs, and snap the front housing together with the rear housing. Ensure the key feature on APC-style connectors faces up.
- Finalize the installation
Cut off the handling stick to remove it from the dust cap if desired.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.