- Simplex LC-UPC connector for OS1/OS2 9/125µm singlemode fiber
- Supports 900µm tight-buffered or 250µm loose-tube fiber installations
- Field termination in ~2 minutes using common splice machine brands
- Meets ISO/IEC 11801, ANSI/TIA-568.3-D, and FOCIS standards
- RoHS-compliant with corrosion-resistant materials for outdoor use
Specifications
Application | Used for initial installation of fiber links, MAC work, or repairs to existing links to minimize downtime. |
Color | Blue |
Standard | RoHS compliant. Exceed TIA/EIA-568-B.3 requirements, TIA/EIA-604 FOCIS-10 |
Type | Fiber Optic Connector |
Width | NA In. |
Package Dimensions (L x W x H) | 12 IN x 6 IN x 1.5 IN |
Package Weight (Imperial) | 0.166 lbs |

CJ688TGBU-24
The Mini-Com Cat 6 UTP RJ45 TG Jack Module is designed to terminate 4-pair, 22-26 AWG twisted pair cable. Each module is 100% factory tested to exceed industry standard performance requirements. TG style termination eliminates the need for a termination tool. Each jack is individually serialized for traceability and is compatible with Mini-Com Modular Patch Panels and Faceplates. The jack module is blue and includes 24 per package.Frequently Asked Questions
What standards do these connectors meet?
The connectors are TIA/EIA-604 FOCIS-3 (SC) and FOCIS-10 (LC) compatible, and exceed TIA/EIA-568-D.3 performance requirements.
What are the specifications for FLCS2/9SOCU9BU?
FLCS2/9SOCU9BU is a Simplex LC, UPC, Blue connector for 9/125μm OS1/OS2 fiber, with 0.15dB average IL and >55dB RL.
Do these connectors require index-matching gel?
No, these connectors do not require index-matching gel due to factory pre-polished end-faces.
What are the return loss specifications?
Singlemode fiber has >55dB (UPC) or >65dB (APC) return loss; multimode fiber has >30dB (UPC) return loss.
What are the insertion loss specifications?
Singlemode fiber has an average insertion loss of 0.15dB (max 0.30dB), and multimode fiber has an average of 0.10dB (max 0.25dB).
What type of ferrule is used?
The connectors use a factory polished zirconia ceramic ferrule.
What fiber types and sizes are compatible?
They are compatible with 9/125μm Singlemode (OS1/OS2) and 50/125 Multimode (OM2, OM3, OM4) fibers, supporting 250μm coated or 900μm tight buffered fiber.
Are these connectors compatible with Sumitomo splice units?
Yes, these splice-on connectors are compatible with Sumitomo brand splice units.
What is the operating temperature range?
The functional temperature range for these connectors is from -40°C to 75°C.
Do these connectors require field polishing or adhesives?
No, the connectors include a pre-polished fiber, eliminating the need for field polishing and adhesives.
How to Install the Panduit Fusion-Splice Connectors
This guide provides step-by-step instructions for installing Panduit fusion-splice connectors using compatible splice machines.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Fusion-splice connectors, Splice protection sleeves, Lint-free wipes, Fiber cleaning solution
- Prepare the splice machine
Follow the initiation steps specific to your splice machine, including powering up, performing arc tests, and ensuring proper cleaning and maintenance.
- Strip the fiber
Strip approximately 35mm of buffer and acrylate off of the fiber using wire strippers. Ensure that the fiber is clean and free from any debris.
- Cleave the fiber
Cleave the bare fiber to a length of 10mm. If the fiber does not cleave, ensure that all acrylate coating has been removed.
- Insert the fiber into the splice holder
Place the cleaved fiber into the left-side fiber holder of the splice machine according to the manufacturer's instructions.
- Prepare the connector assembly
Open the connector assembly blister pack from right to left, ensuring to grab the handling stick rather than the fiber stub end.
- Position the connector in the holder
Insert the connector assembly into the disposable plastic holder with the fiber stub protruding to the left and the handling stick to the right.
- Initiate the splice process
Close the holder on the right side of the splice area and then close the wind cover of the splice stage. Start the splice process if required by your machine.
- Complete the splice
Once the splice is completed, gently slide the splice protection sleeve up to the rear of the fiber holder and open both holders.
- Heat the splice
Place the splice point in the heater of the splice machine, ensuring the splice protection sleeve is centered. Close the heater cover and start the heating process.
- Assemble the connector
After the heating and cooling cycle is complete, remove the assembly from the heating area and snap the front housing together with the rear housing.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.