- 24-fiber capacity for high-density fiber management.
- Multimode OM5 fiber support for advanced applications.
- LC Duplex connectors to discrete pigtails for flexible termination.
- Ultra Low Insertion Loss (Ultra IL) for superior signal integrity.
- Designed for integration with Molex Fiber Management Systems and enclosures.
Specifications
Application | FlexCore ODF/OSF |
Color | Black |
Connection | LC |
Connector 1 Type* | LC Duplex |
Connector 2 Type* | Unterminated |
Fiber Type | OM5 |
Insertion Loss | 0.1 dB |
Material | Polycarbonate |
Standard | ISO/IEC 11801, ANSI/TIA-568-C.3, TIA-604-5, (FOCIS-5), TIA-604-10 (FOCIS-10), RoHS 2002/95/EC compliant, supports IEEE802.3 and ANSI T11.2 (Fiber Channel) |
Type | Fiber Cassette |
Package Dimensions (L x W x H) | 9.9 IN x 13 IN x 1.3 IN |
Package Weight (Imperial) | 0.81 lbs |

F9UYBXLNNSNM015
OS2 Single Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC Cassette, Left side Blunt end, Standard Insertion Loss, No pulling Eye - 15 Meters
FSUYPXRNNNNF050
OM4+ Signature Cord Multi Mode 24 Fiber Indoor Small Diameter Trunk, Plenum, FlexCore Front Access ODF LC Cassette, Right side Blunt end, Ultra Insertion Loss, No pulling Eye - 50 Feet
FDC9N-24-10ASRH
FlexCore Front Access ODF Fiber Optic Cassette, Singlemode (OS2) 24-fiber LC Duplex to 2xMPO-12, Method A Straight, Standard IL, Right Hand Orientation
FDC9N-24-LAASLH
FlexCore Front Access ODF Fiber Optic Cassette, Singlemode (OS2) 24-fiber LC/APC Duplex to 2xMPO-12, Method A Straight, Standard IL, Left Hand Orientation
FDCSA-24-10ASLH
FlexCore Front Access ODF Fiber Optic Cassette, Signature Core (OM4+) 24-fiber LC Duplex to 2xMPO-12, Method A Straight, Ultra IL, Left Hand Orientation
FZUYBXRNNONM015
OM4 Multi Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC Cassette, Right side Blunt end, Optimized Insertion Loss, No pulling Eye - 15 Meters
FDCSA-24-10ASRH
FlexCore Front Access ODF Fiber Optic Cassette, Signature Core (OM4+) 24-fiber LC Duplex to 2xMPO-12, Method A Straight, Ultra IL, Right Hand OrientationFrequently Asked Questions
What is the maximum fiber capacity of a single FlexCore frame?
A single FlexCore frame (600mm) has a maximum capacity of 3168 fibers when using 24F LC cassettes.
What are the dimensions of a single FlexCore frame?
A single FlexCore frame is 2133mm high (2159-2200mm with leveling feet), 1050mm wide, and 300mm deep.
What are the seismic requirements met by the ODF frame?
The robust ODF frame with configuration options meets Telcordia Zone 3 seismic requirements.
How many 4 RU enclosures can each frame hold?
Each FlexCore frame can hold up to eleven 4 RU enclosures, with each enclosure containing twelve sliding trays.
What types of cassettes are compatible with FlexCore frames?
FlexCore frames accept MPO-LC, LC-Tethered, LC-Splice, and Splice-Through cable cassettes.
What is the recommended patch cord length for a single cross connect frame?
The recommended patch cord length for a single cross connect frame is 4m.
What type of patch cords are required for a Double Frame (Compact) Cross Connect?
Duplex LC patch cords must be less than 2mm outside diameter unitary cable (Uniboot patch cord) for this configuration.
Are locks available for the FlexCore enclosures and ODF doors?
Yes, multi-layer security with lock capability is available as an option for both 4 RU enclosures and ODF doors.
What are the available modular building block widths for the frame units?
The modular building blocks for the frame units are available in 150mm, 300mm, and 600mm widths.
What is the maximum insertion loss for OS2 pre-terminated ODF enclosures?
The maximum insertion loss for OS2 pre-terminated ODF enclosures is 0.5dB for LC/APC Duplex and 0.6dB for LC Duplex.
How to Install the FDSWA-24-10P Fiber Splice Cassette
This guide provides step-by-step instructions for installing and configuring the FDSWA-24-10P Fiber Splice Cassette, ensuring proper fiber management and splicing.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Pan-Ty cable ties, Splice sleeves, Electrical tape
- Prepare the fiber cable
Strip the incoming outer cable field jacket to 39 inches [990mm] and secure it with Pan-Ty cable ties and aramid yarn using screws if necessary.
- Install the splice cassette
Mount the FDSWA-24-10P splice cassette onto the designated area, ensuring it is securely attached and level.
- Expose fiber ends for splicing
Expose all fiber ends by sliding a splice sleeve onto either the pigtail or field fiber, then splice all fibers and heat the splice sleeves according to the splicer manufacturer's instructions.
- Install the cover
Place the cover on the base of the splice cassette, aligning the side cover latches, and slide the cover forward until the latch engages with the base.
- Verify installation
Use a multimeter to check the continuity of the fibers and ensure that all connections are secure and functioning properly.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.