Contact for Pricing
Overview
- 24-fiber Singlemode (OS2) LC Duplex to 2xMPO-12 conversion with Method A straight polarity
- Standard insertion loss performance optimized for OS2 singlemode fiber
- Right-hand orientation for clear labeling and front-access cable management
- Factory-terminated, low-loss MPO-12 connectors for reliable, repeatable deployments
- Compatible with Panduit FlexCore and standard rack/wall-mount enclosures
Specifications
Application | FlexCore ODF/OSF |
Color | Black |
Connection | MPO |
Connector 1 Type* | LC Duplex |
Connector 2 Type* | MPO-12 Male |
Fiber Type | OS2 |
Insertion Loss | 0.75 |
Material | Polycarbonate |
Standard | ISO/IEC 11801, ANSI/TIA-568-C.3, TIA-604-5, (FOCIS-5), TIA-604-10 (FOCIS-10), RoHS 2002/95/EC compliant, supports IEEE802.3 and ANSI T11.2 (Fiber Channel) |
Type | Fiber Cassette |
Package Dimensions (L x W x H) | 9.9 IN x 13 IN x 1.3 IN |
Package Weight (Imperial) | 0.81 lbs |

FDS9N-24-10R
FlexCore Front Access ODF Fiber Optic Splice Cassette, Singlemode (OS2) 24-fiber LC Duplex to Ribbon Pigtails, Standard IL
FDC9N-24-LAASLH
FlexCore Front Access ODF Fiber Optic Cassette, Singlemode (OS2) 24-fiber LC/APC Duplex to 2xMPO-12, Method A Straight, Standard IL, Left Hand Orientation
FDCSA-24-10ASLH
FlexCore Front Access ODF Fiber Optic Cassette, Signature Core (OM4+) 24-fiber LC Duplex to 2xMPO-12, Method A Straight, Ultra IL, Left Hand Orientation
FZUYBXRNNONM015
OM4 Multi Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC Cassette, Right side Blunt end, Optimized Insertion Loss, No pulling Eye - 15 Meters
FDCSA-24-10ASRH
FlexCore Front Access ODF Fiber Optic Cassette, Signature Core (OM4+) 24-fiber LC Duplex to 2xMPO-12, Method A Straight, Ultra IL, Right Hand Orientation
FDCZO-24-10URH
FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM4) 24-fiber LC Duplex to 2xMPO-12, Universal, Optimized IL, Right Hand Orientation
FDSZO-24-10P
FlexCore Front Access ODF Fiber Optic Splice Cassette, Multimode (OM4) 24-fiber LC Duplex to Discrete Pigtails, Optimized IL
FDCZO-24-10ASLH
FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM4) 24-fiber LC Duplex to 2xMPO-12, Method A Straight, Optimized IL, Left Hand OrientationFrequently Asked Questions
What type of cassette is FDCZA-24-10ULH?
It is a FlexCore MPO-LC Cassette, designed for connecting LC Duplex to 2 MPO12 connectors.
How many fibers does the FDCZA-24-10ULH cassette support?
The FDCZA-24-10ULH cassette supports 24 fibers.
What fiber type does the FDCZA-24-10ULH cassette use?
The FDCZA-24-10ULH cassette uses OM4 fiber type.
What is the insertion loss performance of FDCZA-24-10ULH?
The FDCZA-24-10ULH cassette offers ULTRA IL (Ultra Insertion Loss) performance.
What polarity method does the FDCZA-24-10ULH cassette use?
The FDCZA-24-10ULH cassette uses Universal Polarity.
Is the FDCZA-24-10ULH cassette left-handed or right-handed?
The FDCZA-24-10ULH cassette is a left-hand configuration.
What are the connector types on the FDCZA-24-10ULH cassette?
The FDCZA-24-10ULH cassette features LC Duplex connectors on one side and 2 MPO12 connectors on the other.
Are FlexCore cassettes compatible with HD Flex™ Cassette styles?
No, FlexCore cassette styles are not suitable for HD Flex™ Cassette styles with both front and rear facing connectivity.
Can FlexCore cassettes be field terminated?
Yes, FlexCore cassettes can be either factory or field terminated.
How many 4 RU enclosures can a FlexCore frame hold?
Each FlexCore frame can hold up to eleven 4 RU enclosures.
How to Install the FlexCore 4RU Universal Enclosure
This guide provides step-by-step instructions for installing the FlexCore 4RU Universal Enclosure in a rack, ensuring proper mounting and cable management.
Estimated time: 45m
Tools needed:
Phillips Head Screwdriver, Wire Strippers, Multimeter
Supplies needed:
#12-24 screws, #10-32 x 1/4” screws, Cable ties, Labels
- Remove the shipping bracket
Unscrew the Phillips head screws on the top and bottom of the enclosure to remove the shipping bracket.
- Mount the enclosure brackets
Position the enclosure mounting brackets between existing rack screws, aligning the bottom flanges with the RU tick marks. Partially install two #12-24 screws to secure the brackets without fully tightening.
- Secure the enclosure
Slide the enclosure onto the mounting brackets and install eight #10-32 x 1/4” screws through the brackets into the enclosure. Fully tighten the #12-24 screws to secure the brackets to the rack.
- Install cassettes
Open the enclosure door and slide the tray out to the second stop position. Disconnect any patch cords if replacing cassettes, lift the cassette up to disengage, and install the new cassette.
- Label the installation
Apply the provided labels to the tray surfaces according to the cassette configuration, ensuring proper identification as per EIA606-B standards.
- Verify installation
Check all screws are tightened and that the enclosure is securely mounted. Use a multimeter to verify proper electrical connections if applicable.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.