Panduit E42G02LTAA - TAA EL2P MSPO PDU, 60 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 2P+E 6h 60A (IP44)-3M, BLACK
Panduit

E42G02LTAA

UPC: 613056915893


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit E42G02LTAA is a TAA-compliant, 60 Amp, 240V (typical for 60A IEC 60309 2P+E 6h 60A) 2-Phase Metered Strip Power Distribution Unit (PDU) designed for robust power management in data centers and industrial environments. This unit features a comprehensive outlet configuration, including (21) C13/C15 outlets and (21) C13/C15/C19/C21 outlets, providing a total of 42 outlets to support a diverse range of IT and industrial equipment. The PDU is equipped with a 3-meter power cord terminated with an IEC 60309 2P+E 6h 60A plug, ensuring secure and high-current power delivery. The IP44 rating indicates protection against solid objects larger than 1mm and water splashes from any direction, suitable for environments where dust and moisture are present. The E42G02LTAA facilitates efficient power distribution and monitoring, crucial for maintaining operational uptime and managing energy consumption. Its construction and specifications are aligned with industry standards for reliability and safety. Manufacturer: Panduit. SKU: E42G02LTAA. UNSPSC Code: 39121031.
  • TAA Compliant for government and regulated environments.
  • 60 Amp, 2-Phase Metered Strip PDU for high-density power distribution.
  • Total of 42 outlets: (21) C13/C15 and (21) C13/C15/C19/C21.
  • Includes IEC 60309 2P+E 6h 60A plug with a 3-meter power cord.
  • IP44 rating provides protection against solid objects and water splashes.

Specifications

Color
Black
Current Rating
60 A
Frequency Rating, Maximum
240 V
Frequency Rating, Minimum
240 V
Ip Rating
IP44
Material
Metal
Mounting
Vertical
Phase
1
Poles
2P+E
Series
TAA EL2P MSPO PDU
Standard
UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
70.08 IN x 3 IN x 3 IN
Package Dimensions (L x W x H)
178.0032 cm x 7.62 cm x 7.62 cm
Package Weight (Imperial)
29.7600 L
Package Weight (Metric)
13.4991 kg
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.

CPP24FMWBLY

The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
Ethernet SHDSL Extender

DDW-120

Ethernet SHDSL Extender
24U 21.34W 31.5D CABINET BLK

REFK1904231BK1

24U 21.34W 31.5D CABINET BLK
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!

CUSTOMDIN

DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What is the maximum operating temperature for Panduit PDUs?

Panduit PDUs are built with premium components to withstand 140°F (60°C) at full load, ensuring reliable operation in high-temperature environments.

Are Panduit PDUs compatible with Cisco Nexus Dashboard?

Yes, Panduit's intelligent PDUs seamlessly integrate with Cisco Nexus Dashboard software to enhance energy savings and sustainability insights.

Do Panduit PDUs support hot-swappable controllers?

Yes, many Panduit PDUs feature hot-swappable controllers that can be replaced or reoriented without affecting outlet status or losing power.

Can Panduit PDUs be mounted without tools?

Yes, vertical Panduit PDUs feature tool-less mounting buttons for quick and secure setup, allowing effortless attachment to rack keyhole slots.

What types of outlets are available on Panduit PDUs?

Panduit PDUs offer various outlet types including C13, C19, and NEMA 5-20R. Some models feature combination outlets that can be used as C21, C19, C15, or C13.

What is the power capacity range for Universal PDUs?

Panduit Universal PDUs support power requirements from 3.3kW to 27.6kW, offering flexibility to adapt to changing power needs by swapping the input cord.

Do Panduit PDUs offer environmental monitoring?

Yes, many Panduit PDUs support environmental monitoring, allowing real-time tracking of temperature, humidity, and leak detection to protect IT assets.

Can Panduit PDUs be managed with software?

Yes, Panduit SiteCommand Utility software enables bulk configuration and firmware updates for ES2P and EL2P series iPDU management.

What is the maximum daisy chain capacity for Panduit PDUs?

The maximum daisy chain capacity varies by series: ES2P supports 16, G6 supports 32, and EL2P supports 64 PDUs.

Are Panduit PDUs suitable for global deployment?

Yes, Universal PDUs feature a universal inlet design and broad voltage compatibility, allowing global deployment by simply swapping the appropriate facility type cord.

How to Install and Connect a Panduit EL2P PDU

This guide provides step-by-step instructions for installing, grounding, and connecting a Panduit EL2P Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet, including optional network controller rotation and initial configuration.

Estimated time: 45m

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Cage nuts, Ground bonding cable, Mounting screws

  1. Prepare for PDU Installation

    Before beginning, ensure all circuit breakers are in the off position. Verify that the PDU will be connected to a circuit providing appropriate branch circuit overcurrent protection. Gather all required tools and ensure the installation environment is temperature and humidity controlled, free of conductive contaminants.

  2. Install PDU Mounting Hardware

    For vertical (0U) PDUs, install the mounting buttons into the keyhole slots on the rack's PDU mounting bracket. For horizontal (1U/2U) PDUs, install cage nuts at the desired U location on both front and rear equipment rails, then screw the mounting bracket ears into these rail surfaces. If necessary, rotate or adjust the mounting ears for horizontal PDUs before fastening.

  3. Mount the PDU

    For vertical (0U) PDUs, insert the PDU's mounting buttons into the keyhole slots on the rack's PDU mounting bracket and secure using a #2 Phillips screwdriver to 3.0Nm. Ensure outlets face the center of the rack. For horizontal (1U/2U) PDUs, screw the PDU chassis to the pre-installed mounting brackets using a 2.5mm hex key Allen wrench, tightening the socket head screws. Ensure proper clearance to avoid blocking airflow.

  4. Ground the PDU

    Connect a ground bonding cable from the external ground bonding point on the PDU chassis to a known earthed reference terminal in the building or to the rack's grounding strip/bus bar. Ensure conductor sizes meet national or local electrical codes (e.g., 14 AWG for up to 15A, 12 AWG for up to 20A).

  5. Rotate Network Controller (Optional)

    If a specific orientation of the network controller's physical ports is desired, use a T10 Torx screwdriver to remove the two retaining screws. Disconnect the ribbon cable to prevent damage, manually rotate the controller, then carefully reconnect the ribbon cable, avoiding crimping or pinching. Reinstall and torque the screws to 2.2–3.1 lbf-in [0.25–0.35 N-M].

  6. Connect PDU to Power Source

    Ensure the feed circuit breaker is OFF and all PDU circuit breakers are ON. Connect the PDU's input power cord to an appropriately rated, grounded branch circuit, adhering to all local and national electrical codes. Verify the PDU's input ratings from its compliance label. Turn the feed circuit breaker ON and wait for the operating system to load.

  7. Perform Initial Configuration (Optional)

    For dual-rated PDUs, an additional CLI configuration step is required to enable the Web interface to report the correct power capacity. Refer to the PDU User Manual for specific CLI Commands to complete this configuration.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.