Panduit E36G33LTAA - TAA EL2P MSPO PDU, 30/32 AMP, (18)C13/C15, (18)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK

Panduit E36G33LTAA TAA EL2P MSPO PDU, 30/32 AMP, (18)C13/C15, (18)C13/C15/C19/C21, IEC 60309 3P+N+E 6h…

UPC: 613056916111


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit TAA EL2P MSPO PDU (SKU: E36G33LTAA) is a 30/32 amp power distribution unit designed for mission-critical industrial and commercial applications. This unit features (18) C13/C15 outlets and supports additional compatibility with C19/C21 plugs, providing flexibility for high-power equipment. The IEC 60309 3P+N+E 6h 30A/32A input connector ensures compatibility with standard industrial power infrastructure. With an IP44 ingress protection rating, the PDU is protected against solid objects over 1mm and water splashes from any direction, making it suitable for harsh environments. The 3-meter cord length allows for flexible installation in data centers, manufacturing floors, or temporary power setups. This PDU meets TAA compliance requirements, making it ideal for government and enterprise procurement. The black housing provides a professional appearance while resisting corrosion and UV exposure. Use this PDU to distribute stable, high-current power to servers, networking equipment, or industrial machinery with confidence in its safety and reliability.
  • 30/32 amp rated power distribution unit
  • 18 C13/C15 outlets with C19/C21 compatibility
  • IEC 60309 3P+N+E 6h 30A/32A input connector
  • IP44 rated for protection against dust and water splashes
  • 3-meter cord length for flexible installation

Specifications

Color
Black
Connection Type
IEC 60309
Connection Type
IEC 60309 3P+N+E 6h
Current Rating
30/32 A
Frequency Rating, Maximum
240 V
Frequency Rating, Minimum
240 V
Ip Rating
IP44
Material
Metal
Mounting
Vertical
Phase
3
Poles
3P+N+E
Series
EL2P MSPO
Series
TAA EL2P MSPO PDU
Standard
UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
70.08 IN x 3 IN x 3 IN
Package Dimensions (L x W x H)
178.0032 cm x 7.62 cm x 7.62 cm
Package Weight (Imperial)
20.9400 L
Package Weight (Metric)
9.4984 kg
This Panduit G5 Basic PDU features (12) 5-20R outlets. It is a 20 amp, 120 V, single phase PDU with a NEMA 5-20P input plug and a 10 foot (3m) power cord. The PDU is black.

P12B19M

This Panduit G5 Basic PDU features (12) 5-20R outlets. It is a 20 amp, 120 V, single phase PDU with a NEMA 5-20P input plug and a 10 foot (3m) power cord. The PDU is black.
MI 208V 30A 42CX

EN1851

MI 208V 30A 42CX
19-inch Rack Mount Outlet Strip, 20A, 8 Switches & 8 Outlets, 15 ft cord, Black

1589W8G1BKRR

19-inch Rack Mount Outlet Strip, 20A, 8 Switches & 8 Outlets, 15 ft cord, Black
TAA EL2P MS PDU, 60/63 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 60A/63A (IP44)-3M, BLACK

E48E25LTAA

TAA EL2P MS PDU, 60/63 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 60A/63A (IP44)-3M, BLACK
TAA EL2P MSPO PDU, 20/16 AMP, (18)C13/C15, (18)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 20A/16A (IP44)-3M, BLACK

E36G32LTAA

TAA EL2P MSPO PDU, 20/16 AMP, (18)C13/C15, (18)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 20A/16A (IP44)-3M, BLACK
TAA EL2P MS PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L15-30P-3M, BLACK

E48E22LTAA

TAA EL2P MS PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L15-30P-3M, BLACK
TAA EL2P MSPO PDU, 60 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 2P+E 6h 60A (IP44)-3M, BLACK

E42G02LTAA

TAA EL2P MSPO PDU, 60 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 2P+E 6h 60A (IP44)-3M, BLACK
TAA EL2P MSPO PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L15-30P-3M, BLACK

E48G32LTAA

TAA EL2P MSPO PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L15-30P-3M, BLACK

Frequently Asked Questions

What is the standard warranty for Panduit PDUs?

Panduit PDUs come with a 3-year standard warranty, which can be extended to 5 years.

What is the maximum operating temperature?

Panduit PDUs are built with premium components to withstand 140°F (60°C) at full load.

Do Panduit PDUs feature hot-swappable controllers?

Yes, Panduit PDUs feature hot-swappable controllers that can be removed without affecting outlet status, ideal for service or repair.

What network connectivity options are available?

PDUs offer single or dual Gigabit Ethernet and serial connectivity. Some models also support Wi-Fi and Bluetooth via CNT06.

What can Panduit PDUs monitor in real-time?

Panduit PDUs provide real-time monitoring of power, environmental conditions, and cabinet security.

Are Panduit PDUs compatible with Cisco systems?

Yes, Panduit's intelligent PDUs are compatible with Cisco Nexus Dashboard software for enhanced energy savings and sustainability insights.

Do Panduit PDUs integrate with DCIM solutions?

Yes, intelligent PDUs offer integration with monitoring software for data management and analytics, with EL2P series having native Cisco Nexus Dashboard and Redfish API integration.

What is the maximum daisy chain capacity?

Daisy chain capacity varies by model, with ES2P supporting 16, G6 supporting 32, and EL2P supporting up to 64 PDUs.

What is the metering accuracy of Panduit PDUs?

Metering accuracy is ± 2% for ES2P and G6 models, and ± 0.5% for EL2P models.

How are vertical PDUs mounted?

Vertical PDUs feature tool-less mounting buttons for quick and secure attachment to rack keyhole slots, simplifying setup.

How to Install and Connect a Panduit Rack PDU

This guide provides step-by-step instructions for mounting, grounding, and connecting a Panduit Rack Power Distribution Unit (PDU) in a datacenter rack or cabinet, including optional network controller rotation.

Estimated time: 45m

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Mounting hardware, Cage nuts, Ground bonding cable, Power cord

  1. Mount the PDU in the Rack

    For vertical PDUs, insert the pre-installed mounting buttons into the keyhole slots on the rack's PDU mounting bracket. Secure with a #2 Phillips screwdriver to a recommended torque of 3.0Nm. For horizontal PDUs, install cage nuts at the desired U location on both front and rear rails, then screw the mounting bracket ears into the RETMA rail surfaces. Use a 2.5mm hex key Allen wrench to fasten front mounting brackets to the PDU chassis. Ensure a minimum clearance of 2 to 3 inches between the PDU chassis and cabinet frame to avoid blocking airflow.

  2. Ground the PDU

    Connect a ground bonding cable from the external ground bonding point on the PDU chassis to a known earthed reference terminal in the building or the rack's grounding strip/bus bar. Ensure the conductor size meets national or local electrical codes (e.g., 14 AWG for up to 15A, 12 AWG for up to 20A). This is critical to reduce the risk of electric shock due to high leakage currents. Use the external earthing screw with a star washer for supplementary Earth bonding to the rack metalwork.

  3. Connect the PDU to a Power Source

    WARNING: Ensure all circuit breakers are in the off position before connecting input power. Turn the feed circuit breaker Off. Verify all circuit breakers on the PDU are set to On. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) branch circuit, adhering to all local and national electrical codes. Ensure the outlet is near the equipment and easily accessible. Turn the feed circuit breaker On. Wait for the operating system to load; the Main Menu will display on the screen.

  4. Rotate the Network Controller (Optional)

    If a specific orientation of the physical ports is preferred, use a T10 Torx screwdriver to remove the two screws holding the network controller. Disconnect the ribbon cable to prevent damage. Rotate the controller to the desired orientation, then carefully reconnect the ribbon cable, avoiding crimping or pinching. Reinstall and torque the two screws to 2.2–3.1 lbf-in [0.25–0.35 N-M]. Overtightening may cause metal deformation.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.