Hammond Power CD1X0365F1 - dV/dT filter 365 amperes up to 600 volts open style 1000 feet
Hammond Power

CD1X0365F1

UPC: 803423203481


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power CD1X0365F1 dV/dT filter is engineered to mitigate voltage spikes and reduce motor insulation stress when used with variable frequency drives (VFDs) and motors, particularly over extended cable lengths. This open-style filter is rated for 365 amperes and operates up to 600 volts, making it suitable for a variety of industrial applications. The inclusion of 1000 feet of cable in this configuration provides significant flexibility for installations requiring greater separation between the VFD and the motor. dV/dT filters are crucial for protecting motor windings from the damaging effects of high-frequency switching that can occur with VFD operation, especially when motor lead lengths exceed recommended limits. By absorbing these voltage transients, the CD1X0365F1 helps to extend motor life and improve overall system reliability. This unit, manufactured by Hammond Power, is designed for robust performance in demanding environments where VFDs are employed. Its open style allows for efficient heat dissipation and integration into existing control panels or enclosures. The SKU CD1X0365F1 signifies a specific configuration designed for high current and voltage applications, ensuring compatibility with powerful motor systems.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Includes 1000 feet of cable for extended motor runs
  • Designed to reduce motor insulation stress from VFDs

Specifications

Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
365 A
Enclosure Type
Open Frame
Height
12.75 in
Length
12.5 in
Length
317.5 mm
Maximum Operating Temperature
50
Standard
cUL
Type
dV/dT Filter
Voltage Drop
Less than 3%
Voltage Rating
600 V
Voltage Rating
480/600 V
Weight
105 lbs
Width
16.5 in
Package Dimensions (L x W x H)
12.5 IN x 16.5 IN x 12.75 IN
Package Dimensions (L x W x H)
317.5 mm x 419.1 mm x 323.85 mm
Package Weight (Imperial)
105.000 L
Package Weight (Metric)
47.627 kg
dV/dT filter 415 amperes up to 600 volts open style 1000 feet

CD1X0415F1

dV/dT filter 415 amperes up to 600 volts open style 1000 feet
dV/dT filter 305 amperes up to 600 volts open style 1000 feet

CD1X0305F1

dV/dT filter 305 amperes up to 600 volts open style 1000 feet
dV/dT filter 515 amperes up to 600 volts open style 1000 feet

CD1X0515F1

dV/dT filter 515 amperes up to 600 volts open style 1000 feet
dV/dT filter 600 amperes up to 600 volts open style 1000 feet

CD1X0600F1

dV/dT filter 600 amperes up to 600 volts open style 1000 feet
dV/dT filter 750 amperes up to 600 volts open style 1000 feet

CD1X0750F1

dV/dT filter 750 amperes up to 600 volts open style 1000 feet
dV/dT filter 200 amperes up to 600 volts open style 1000 feet

CD1X0200F1

dV/dT filter 200 amperes up to 600 volts open style 1000 feet
dV/dT filter 250 amperes up to 600 volts open style 1000 feet

CD1X0250F1

dV/dT filter 250 amperes up to 600 volts open style 1000 feet
dV/dT filter 160 amperes up to 600 volts open style 1000 feet

CD1X0160F1

dV/dT filter 160 amperes up to 600 volts open style 1000 feet
dV/dT filter 130 amperes up to 600 volts open style 1000 feet

CD1X0130F1

dV/dT filter 130 amperes up to 600 volts open style 1000 feet
Active Harmonic Filter 480V 50A 60Hz ETH open style

WAHF1K050F

Active Harmonic Filter 480V 50A 60Hz ETH open style
Active Harmonic Filter 480V 50A 60Hz ETH open;used on 400V

WAHF1K050F-E6H

Active Harmonic Filter 480V 50A 60Hz ETH open;used on 400V
Active Harmonic Filter 480V 50A 60Hz ETH open;used on 600V w/auto

WAHF1K050F-E6P1

Active Harmonic Filter 480V 50A 60Hz ETH open;used on 600V w/auto

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and proper operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Carefully inspect the dV/dT filter for any transit damage and ensure all parts are included according to the shipping documents. If any damage is found, do not energize the unit and contact the manufacturer.

  2. Mount the filter

    Securely mount the dV/dT filter to a suitable surface using the provided mounting screws. Ensure it is positioned in a dry area with adequate ventilation.

  3. Connect wiring

    Connect the output phases A1, B1, and C1 to the corresponding phases U, V, and W of the variable frequency drive. Connect A2, B2, and C2 to T1, T2, and T3 of the motor, ensuring all connections are tight and secure.

  4. Ground the filter

    Ensure the dV/dT filter is properly grounded according to local electrical codes. Verify that all ground connections are secure before proceeding.

  5. Verify connections

    Use a multimeter to check that all electrical connections are tight and that there are no shorts. Confirm that power is turned off before proceeding.

  6. Energize the filter

    Once all connections are verified and secure, replace all covers and doors, then turn on the power to the dV/dT filter. Monitor for any unusual sounds or issues.

  7. Perform initial calibration

    Follow the manufacturer's guidelines to perform any necessary calibration procedures to ensure the dV/dT filter operates within specified parameters.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.