Overview

The Hammond Power CD1X0515F1 dV/dT filter (SKU: CD1X0515F1) is a three-phase iron core line reactor with integrated resistors designed to mitigate voltage spikes and reflected wave phenomena in motors driven by variable frequency drives (VFDs). Rated for 515 amperes continuous current and 600 volts maximum, this open-style filter supports cable lengths up to 1000 feet, reducing peak voltages at the motor to prevent insulation stress and premature failure. The filter features differential mode inductance with a three-phase iron core reactor, suitable for fundamental frequencies up to 60Hz (90Hz with de-rating) and VFD carrier frequencies up to 4kHz. Terminals are marked A1, B1, C1, A2, B2, and C2, with construction allowing 150% RMS overload for 60 seconds once every 10 minutes. Ideal for large industrial facilities with extended cable runs between VFDs and motors, the CD1X0515F1 is designed for high-performance applications requiring reliable motor protection and extended service life. The open-style construction provides efficient heat dissipation, while the integrated resistors enhance voltage spike suppression.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Differential mode inductance with 150% RMS overload capability for 60 seconds
  • Open-style construction with terminal markings A1, B1, C1, A2, B2, C2

Specifications

Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
515 A
Enclosure Type
Open Frame
Height
12.75 in
Length
12.5 in
Length
317.5 mm
Maximum Operating Temperature
50
Mounting Type
Open Style
Nema Rating
Open Style
Series
dV/dT Filter
Series
CD1X
Size
1000 ft
Standard
cUL
Type
dV/dT Filter
Voltage Drop
Less than 3%
Voltage Rating
480/600 V
Voltage Rating
600 V
Weight
135 lbs
Width
16.5 in
Package Dimensions (L x W x H)
12.5 IN x 16.5 IN x 12.75 IN
Package Dimensions (L x W x H)
317.5 mm x 419.1 mm x 323.85 mm
Package Weight (Imperial)
135.000 L
Package Weight (Metric)
61.235 kg
dV/dT filter 415 amperes up to 600 volts open style 1000 feet

CD1X0415F1

dV/dT filter 415 amperes up to 600 volts open style 1000 feet
DIGIBOX A200 RS_ETH 600V PC

USDBPA200RJ

DIGIBOX A200 RS_ETH 600V PC
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0130E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0415E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0600E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0250E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 200 amperes up to 600 volts open style 1000 feet

CD1X0200F1

dV/dT filter 200 amperes up to 600 volts open style 1000 feet
dV/dT filter 160 amperes up to 600 volts Type 1 1000 feet

CD1X0160E1

dV/dT filter 160 amperes up to 600 volts Type 1 1000 feet

Frequently Asked Questions

What is the primary function of the HPS Centurion D1 dV/dT filter?

The filter mitigates high frequency components and voltage spikes between a VFD and motor, protecting motor windings and cables from damaging peak voltages.

When should HPS Centurion D1 dV/dT filters be used?

They are designed for applications with long cables between the VFD and the motor, and should always be installed next to the IGBT variable frequency drive.

What system voltages are supported by the HPS Centurion D1 filter?

The filter is rated for system voltages up to 600V, specifically for 480V and 600V applications.

What is the current rating range for HPS Centurion D1 filters?

Current ratings range from 2A to 108A. Consult HPS for higher ratings.

What is the maximum recommended motor lead length for this filter?

The maximum recommended motor lead length is 600 ft. Consult HPS for longer lengths.

What is the ambient operating temperature range for the dV/dT filter?

The filter can operate in ambient temperatures from -25°C to 40°C, and is suitable up to 50°C.

What type of enclosure does the CD1X0003F1 model have?

The CD1X0003F1 model has an 'F' enclosure, which signifies an Open Frame type.

How does the dV/dT filter protect the motor?

It slows down the rate of voltage increase and minimizes damaging peak voltages by reducing peak voltage, rise time, and pulse ringing.

What is the voltage drop across the HPS Centurion D1 filter?

The voltage drop across the filter is less than 3%.

What are the typical applications for HPS Centurion D1 series dV/dT filters?

Typical applications include Oil & Gas Pumps, Wastewater Treatment Plants, HVAC Systems, Pulp & Paper, and Irrigation Fields.

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and effective operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Immediately after receiving the dV/dT filter, inspect it for any transit damage and ensure it matches the shipping documents. If any damage is found, do not energize the unit and contact the manufacturer.

  2. Mount the filter

    Securely mount the dV/dT filter in a dry area with adequate ventilation, using the provided mounting screws. Ensure it is positioned correctly in relation to the Variable Frequency Drive (VFD) as per the installation diagram.

  3. Connect the wiring

    Connect the filter's terminals A1, B1, and C1 to the output phases U, V, and W of the VFD. Connect terminals A2, B2, and C2 to T1, T2, and T3 of the motor. Ensure all connections are tight and secure.

  4. Ground the filter

    Ensure the dV/dT filter is properly grounded according to local electrical codes. Verify that all ground connections are secure before proceeding.

  5. Verify connections

    Before energizing the unit, use a multimeter to check that all electrical connections are tight and that there are no short circuits. Confirm that the filter has not been exposed to moisture.

  6. Energize the unit

    Once all checks are complete and the unit is dry, restore power to the dV/dT filter. Monitor for any unusual sounds or overheating during initial operation.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.