Authorized Hammond Power Distributor
Hammond Power CD1X0130F1 - dV/dT filter 130 amperes up to 600 volts open style 1000 feet
More images

Hammond Power CD1X0130F1 dV/dT filter 130 amperes up to 600 volts open style 1000 feet

UPC: 803423203436


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CD1X0130F1 is a three-phase iron core dV/dT filter designed to mitigate voltage spikes and reduce motor insulation stress in variable frequency drive (VFD) applications. This open-style filter is rated for a maximum fundamental voltage of 600VAC and can handle up to 130 amperes. The CD1X0130F1 is suitable for VFD carrier frequencies up to 4kHz and supports motor operation with cable lengths up to 1000 feet. Its construction includes a three-phase iron core reactor with differential mode inductance and resistors. The reactor windings are designed for 150% RMS overload for 60 seconds every 10 minutes. This filter operates effectively in ambient temperatures up to 50 degrees C. The Hammond Power CD1X0130F1 is an essential component for ensuring the reliability and longevity of motor systems operating under VFD control, particularly in installations with extended VFD-to-motor cable runs. It helps prevent premature motor failure by reducing the rate of voltage rise (dV/dt) at the motor terminals.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Reduces voltage spikes and motor insulation stress
  • Open-style construction for efficient heat dissipation

Specifications

Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
130 A
Enclosure Type
Open Frame
Height
7.5 IN
Length
9 IN
Maximum Operating Temperature
50
Mounting Type
Open Style
Standard
cUL
Type
dV/dT Filter
Voltage Drop
Less than 3%
Voltage Rating
480/600 V
Voltage Rating
600 V
Weight
45 lbs
Width
11.25 in
Package Dimensions (L x W x H)
9 IN x 11.25 IN x 7.5 IN
Package Dimensions (L x W x H)
228.6 mm x 285.75 mm x 190.5 mm
Package Weight (Imperial)
45.000 L
Package Weight (Metric)
20.412 kg
dV/dT filter 160 amperes up to 600 volts open style 1000 feet

CD1X0160F1

dV/dT filter 160 amperes up to 600 volts open style 1000 feet
DIGIBOX A200 RS_ETH 600V PC

USDBPA200RJ

DIGIBOX A200 RS_ETH 600V PC
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0305E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 515 amperes up to 600 volts open style 1000 feet

CD1X0515F1

dV/dT filter 515 amperes up to 600 volts open style 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0130E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0415E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0600E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0250E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

Frequently Asked Questions

What is the maximum operating voltage for this dV/dT filter?

The Hammond Power CD1X0130F1 dV/dT filter has a fundamental maximum voltage rating of 600VAC.

What is the maximum current rating for the CD1X0130F1 filter?

This dV/dT filter is rated for a continuous current of up to 130 amperes.

What is the maximum cable length supported by this filter?

The CD1X0130F1 filter is suitable for VFD to motor cable lengths up to 1000 feet.

What is the maximum VFD carrier frequency this filter can handle?

The filter is suitable for a maximum VFD carrier frequency of 4kHz.

What is the ambient temperature rating for this filter?

The filter is suitable for operation in an ambient temperature of up to 50 degrees C.

What is the purpose of a dV/dT filter?

A dV/dT filter reduces the rate of voltage rise (dV/dt) at the motor terminals, mitigating voltage spikes caused by VFDs and long cable lengths, thereby preventing motor failures.

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Carefully inspect the dV/dT filter for any transit damage and ensure all parts are accounted for according to the shipping documents.

  2. Mount the filter

    Securely mount the dV/dT filter to a clean, dry surface using the appropriate mounting screws. Ensure it is positioned for optimal ventilation and accessibility.

  3. Connect wiring

    Connect the filter's terminals A1, B1, and C1 to the output phases U, V, and W of the variable frequency drive, and connect A2, B2, and C2 to T1, T2, and T3 of the motor, following the connection diagram.

  4. Ground the filter

    Ensure that the dV/dT filter is properly grounded according to local electrical codes before energizing the unit.

  5. Verify connections

    Use a multimeter to check the tightness and integrity of all electrical connections, ensuring there are no loose wires or potential short circuits.

  6. Perform insulation resistance test

    Conduct an insulation resistance test to confirm that the filter is dry and safe to energize. The resistance should be greater than 10k ohms.

  7. Energize the filter

    Once all checks are complete and the unit is confirmed to be dry, restore power to the dV/dT filter and monitor for any irregularities.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.