Authorized Hammond Power Distributor
Hammond Power CD1X0600F1 - dV/dT filter 600 amperes up to 600 volts open style 1000 feet
More images

Hammond Power CD1X0600F1 dV/dT filter 600 amperes up to 600 volts open style 1000 feet

UPC: 803423203511


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CD1X0600F1 dV/dT filter is a three-phase iron core line reactor designed to protect motors from damaging voltage spikes and high-frequency harmonics generated by variable frequency drives (VFDs). Rated for 600A and 600VAC, this open-style filter mitigates PWM switching transients and impedance mismatches between VFDs and motors, particularly over extended cable runs up to 1000 feet. The filter features differential mode inductance with a single iron core and three coils, ensuring robust performance in industrial environments. It supports a maximum fundamental frequency of 60Hz at 600V (90Hz with de-rating) and is suitable for VFD carrier frequencies up to 4kHz. The reactor winding handles 150% RMS overload for 60 seconds once every 10 minutes, while resistors are rated up to 60% of the wattage. Terminals are marked A1, B1, C1, A2, B2, and C2 for clear wiring.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Handles 150% RMS overload for 60 seconds (once every 10 minutes)
  • Open style mounting for flexible integration

Specifications

Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
600 A
Enclosure Type
Open Frame
Height
14.75 in
Length
13.5 in
Maximum Operating Temperature
50
Mounting Type
Open Style
Series
CD1X
Standard
cUL
Type
dV/dT Filter
Voltage Drop
Less than 3%
Voltage Rating
480/600 V
Voltage Rating
600 V
Weight
170 lbs
Width
16.5 in
Package Dimensions (L x W x H)
13.5 IN x 16.5 IN x 14.75 IN
Package Dimensions (L x W x H)
342.9 mm x 419.1 mm x 374.65 mm
Package Weight (Imperial)
170.000 L
Package Weight (Metric)
77.111 kg
dV/dT filter 750 amperes up to 600 volts open style 1000 feet

CD1X0750F1

dV/dT filter 750 amperes up to 600 volts open style 1000 feet
DIGIBOX A200 RS_ETH 600V PC

USDBPA200RJ

DIGIBOX A200 RS_ETH 600V PC
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0365E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 415 amperes up to 600 volts open style 1000 feet

CD1X0415F1

dV/dT filter 415 amperes up to 600 volts open style 1000 feet
The industrial software, IntraVUE Edge, is a permanently licensed appliance. IntraVUE Edge continuously monitors the status of all devices and switches within the network. IntraVUE Software will run perpetually, offering long term insights into network functionality, performance, and utilization statistics. Easy to deploy, there is no virtual machine or server commissioning required. IntraVUE Edge only requires IP configuration on the client network.

PNPIV

The industrial software, IntraVUE Edge, is a permanently licensed appliance. IntraVUE Edge continuously monitors the status of all devices and switches within the network. IntraVUE Software will run perpetually, offering long term insights into network functionality, performance, and utilization statistics. Easy to deploy, there is no virtual machine or server commissioning required. IntraVUE Edge only requires IP configuration on the client network.
SmartZone Cloud is a cloud-native, digital infrastructure management software that combines power and environmental monitoring with asset management. It tracks infrastructure data and provides relevant information to data center operations. This is a 1-year subscription per power and environmental infrastructure asset (UPS, RPP/PDU, rack PDU, cooling, etc.). There is no limit on the number of assets that can be added to SmartZone Cloud.

SZC-PEIA1Y

SmartZone Cloud is a cloud-native, digital infrastructure management software that combines power and environmental monitoring with asset management. It tracks infrastructure data and provides relevant information to data center operations. This is a 1-year subscription per power and environmental infrastructure asset (UPS, RPP/PDU, rack PDU, cooling, etc.). There is no limit on the number of assets that can be added to SmartZone Cloud.
SmartZone Cloud is a cloud-native, digital infrastructure management software that combines power and environmental monitoring with asset management. It tracks infrastructure data and provides relevant information to data center operations. This is a 3-year subscription per power and environmental infrastructure asset (UPS, RPP/PDU, rack PDU, cooling, etc.). There is no limit on the number of assets that can be added to SmartZone Cloud.

SZC-PEIA3Y

SmartZone Cloud is a cloud-native, digital infrastructure management software that combines power and environmental monitoring with asset management. It tracks infrastructure data and provides relevant information to data center operations. This is a 3-year subscription per power and environmental infrastructure asset (UPS, RPP/PDU, rack PDU, cooling, etc.). There is no limit on the number of assets that can be added to SmartZone Cloud.
DIRIS MCM-48 with disco.

48270549

DIRIS MCM-48 with disco.

Frequently Asked Questions

What is the maximum VFD carrier frequency this filter can handle?

The filter is suitable for VFD carrier frequencies up to 4kHz.

What is the overload capacity of the reactor winding?

The reactor winding is designed to handle 150% RMS overload for 60 seconds once every 10 minutes.

What are the terminal markings for this filter?

Terminals are marked A1, B1, C1, A2, B2, and C2 for clear identification and wiring.

What is the maximum fundamental frequency this filter supports?

The filter is rated for a maximum fundamental frequency of 60Hz at 600V, with de-rating up to 90Hz.

What standards does this filter comply with?

The filter is designed, constructed, and rated in accordance with UL, CSA, and NEMA standards.

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Immediately after receiving the dV/dT filter, inspect it for any transit damage and ensure it matches the shipping documents. If any damage is found, do not energize the unit and contact the manufacturer.

  2. Mount the filter

    Secure the dV/dT filter to a suitable mounting surface using the provided mounting screws. Ensure it is installed in a dry area with adequate ventilation.

  3. Connect the wiring

    Connect the output phases U, V, and W from the variable frequency drive to terminals A1, B1, and C1 on the dV/dT filter. Connect terminals A2, B2, and C2 to T1, T2, and T3 of the motor. Ensure all connections are tight and secure.

  4. Ground the filter

    Ensure the dV/dT filter is properly grounded according to local codes. Verify that all ground connections are secure before proceeding.

  5. Verify connections

    Use a multimeter to check that all electrical connections are secure and that there are no shorts. Confirm that the unit is de-energized before performing this check.

  6. Perform a dry-out if necessary

    If the dV/dT filter has been exposed to moisture, dry it out using warmed air for at least 24 hours before energizing. Ensure that the insulation resistance is greater than 10k ohms.

  7. Energize the unit

    Once all connections are verified and the unit is dry, replace all covers and doors. Turn on the power supply to the dV/dT filter and monitor for any abnormal conditions.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.