Hammond Power CD1X0160F1 - dV/dT filter 160 amperes up to 600 volts open style 1000 feet
Hammond Power

CD1X0160F1

UPC: 803423203443


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power CD1X0160F1 is an open-style dV/dT filter designed for industrial applications. This filter is specifically engineered for use between variable frequency drives (VFDs) and motors, particularly when longer cable lengths are employed. Its primary function is to mitigate the damaging voltage spikes and reflections that can occur over extended motor leads, thereby protecting the motor's insulation system. With a robust current rating of 160 amperes and a voltage rating of up to 600 volts, the CD1X0160F1 is suitable for a wide range of motor control systems. The open-style construction allows for efficient heat dissipation and easy integration into existing control panels. This filter helps to extend the operational life of motors by reducing stress on their windings, which is crucial for maintaining uptime and reducing maintenance costs in demanding industrial environments. The 1000-foot designation likely refers to the maximum recommended cable length it can effectively manage, ensuring reliable motor operation even at greater distances from the VFD. Utilizing this dV/dT filter is a proactive measure to prevent premature motor failure and ensure consistent performance. SKU: CD1X0160F1. Manufacturer: Hammond Power. UNSPSC: 83101808. Country of Origin: FR.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • 160 ampere current rating
  • 600 volt voltage rating

Specifications

Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
160 A
Enclosure Type
Open Frame
Height
7.5 IN
Length
9 IN
Maximum Operating Temperature
50
Standard
cUL
Type
dV/dT Filter
Voltage Drop
Less than 3%
Voltage Rating
600 V
Voltage Rating
480/600 V
Weight
55 lbs
Width
12.63 in
Package Dimensions (L x W x H)
9 IN x 12.63 IN x 7.5 IN
Package Dimensions (L x W x H)
228.6 mm x 320.802 mm x 190.5 mm
Package Weight (Imperial)
55.000 L
Package Weight (Metric)
24.948 kg
dV/dT filter 130 amperes up to 600 volts open style 1000 feet

CD1X0130F1

dV/dT filter 130 amperes up to 600 volts open style 1000 feet
dV/dT filter 200 amperes up to 600 volts open style 1000 feet

CD1X0200F1

dV/dT filter 200 amperes up to 600 volts open style 1000 feet
dV/dT filter 108 amperes up to 600 volts open style

CD1X0108F

dV/dT filter 108 amperes up to 600 volts open style
dV/dT filter 80 amperes up to 600 volts open style

CD1X0080F

dV/dT filter 80 amperes up to 600 volts open style
dV/dT filter 65 amperes up to 600 volts open style

CD1X0065F

dV/dT filter 65 amperes up to 600 volts open style
dV/dT filter 250 amperes up to 600 volts open style 1000 feet

CD1X0250F1

dV/dT filter 250 amperes up to 600 volts open style 1000 feet
dV/dT filter 365 amperes up to 600 volts open style 1000 feet

CD1X0365F1

dV/dT filter 365 amperes up to 600 volts open style 1000 feet
dV/dT filter 415 amperes up to 600 volts open style 1000 feet

CD1X0415F1

dV/dT filter 415 amperes up to 600 volts open style 1000 feet
dV/dT filter 54 amperes up to 600 volts open style

CD1X0054F

dV/dT filter 54 amperes up to 600 volts open style
dV/dT filter 305 amperes up to 600 volts open style 1000 feet

CD1X0305F1

dV/dT filter 305 amperes up to 600 volts open style 1000 feet
dV/dT filter 108 amperes up to 600 volts type 1

CD1X0108E

dV/dT filter 108 amperes up to 600 volts type 1
dV/dT filter 80 amperes up to 600 volts type 1

CD1X0080E

dV/dT filter 80 amperes up to 600 volts type 1

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and effective operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Immediately after receiving the dV/dT filter, inspect it for any transit damage and ensure it matches the shipping documents. If any damage is found, do not energize the unit and contact the manufacturer.

  2. Mount the filter

    Secure the dV/dT filter to the designated mounting bracket or surface using appropriate mounting screws. Ensure it is level and firmly attached.

  3. Connect the wiring

    Connect the output phases A1, B1, and C1 to the corresponding phases U, V, and W on the variable frequency drive. Connect A2, B2, and C2 to T1, T2, and T3 of the motor, ensuring all connections are tight and secure.

  4. Ground the filter

    Ensure the dV/dT filter is properly grounded according to local electrical codes. Verify that all ground connections are secure before energizing the unit.

  5. Verify connections

    Use a multimeter to check the tightness and integrity of all electrical connections. Confirm that there is no moisture present in the unit before energization.

  6. Energize the unit

    Once all connections are verified and the unit is dry, restore power to the dV/dT filter. Monitor for any unusual sounds or behavior during initial operation.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.