Authorized Hammond Power Distributor
Hammond Power CD1X0108F - dV/dT filter 108 amperes up to 600 volts open style
More images

Hammond Power CD1X0108F dV/dT filter 108 amperes up to 600 volts open style

UPC: 803423168285


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CD1X0108F is an open-style dV/dT filter designed to protect motors from voltage spikes generated by Variable Frequency Drives (VFDs). This filter features a three-phase iron core reactor and is rated for 108 amperes and a maximum fundamental voltage of 600VAC. It is suitable for VFD carrier frequencies up to 4kHz and can accommodate cable lengths up to 1000 feet (with 600ft models available). The dV/dT filter reduces peak voltages at the motor terminals, mitigating stress on motor insulation and preventing premature failure, especially critical for long cable runs between the VFD and motor. The reactor winding is designed for 150% RMS overload for 60 seconds every 10 minutes. The filter operates effectively in ambient temperatures up to 50 degrees C. The CD1X0108F is constructed in accordance with UL, CSA, and NEMA standards. This filter is an essential component for ensuring motor longevity and reliable operation in VFD-driven systems.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Supports motor cable lengths up to 1000 feet
  • Designed for operation in ambient temperatures up to 50 degrees C

Specifications

Altitude
<1000 m
Ambient Operating Temperature
-25C to 40C (suitable to 50C) Deg C
Application
Designed for applications with long cables between the VFD and the motor
Connection Type
Open style
Cooling
Natural Convection
Current Rating
108 A
Enclosure
Open Frame
Height
7 in
Inverter Operating Frequency
up to 60Hz
Inverter Specification
Switching Frequency: 2kHz - 4kHz, Operating Frequency: up to 60Hz
Inverter Switching Frequency
2kHz - 4kHz
Length
7.5 IN
Maximum Ambient Temperature
40C (suitable to 50C)
Minimum Ambient Temperature
-25C
Mounting
Wall/Ceiling/Floor Mount
Mounting Type
Open Style
NEC 480 HP
75
NEC 600 HP
100
Peak Voltage
at Motor: 150% of DC bus voltage
Series
CD1X
Special Features
Peak Voltage at Motor: 150% of DC bus voltage
Standard
cUL
System Voltage
up to 600V
Voltage Rating
600 V
Voltage Rating
up to 600V
Watts Loss
315
Weight
28 lbs
Width
9 IN
Package Dimensions (L x W x H)
7.5 IN x 9 IN x 7 IN
Package Dimensions (L x W x H)
190.5 mm x 228.6 mm x 177.8 mm
Package Weight (Imperial)
28.000 L
Package Weight (Metric)
12.400 kg
dV/dT filter 80 amperes up to 600 volts open style

CD1X0080F

dV/dT filter 80 amperes up to 600 volts open style
POE INJECTOR OUTDOOR LORA GTW

48290940

POE INJECTOR OUTDOOR LORA GTW
dV/dT filter 27 amperes up to 600 volts open style

CD1X0027F

dV/dT filter 27 amperes up to 600 volts open style
Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Open Style

CP1P6G0025F

Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Open Style
dV/dT filter 45 amperes up to 600 volts open style

CD1X0045F

dV/dT filter 45 amperes up to 600 volts open style
Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Open Style

CP1P6G0040F

Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Open Style
dV/dT filter 35 amperes up to 600 volts open style

CD1X0035F

dV/dT filter 35 amperes up to 600 volts open style
Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Open Style

CP1P6G0049F

Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Open Style

Frequently Asked Questions

What is the purpose of the HPS Centurion D1 dV/dT filter?

The D1 filter mitigates high frequency components and voltage spikes between a VFD and motor, protecting the motor by slowing voltage increase and minimizing peak voltages.

When should HPS Centurion D1 dV/dT filters be used?

These filters are designed for applications with long cables between the VFD and the motor and should always be installed next to the IGBT variable frequency drive.

What system voltages are supported by the HPS Centurion D1 filter?

The filter is rated for system voltages up to 600V, specifically for 480V and 600V applications.

What is the current rating range for HPS Centurion D1 filters?

The current rating ranges from 2A to 108A. Consult HPS for higher ratings.

What is the maximum recommended motor lead length for this filter?

The maximum recommended motor lead length is 600 ft. Consult HPS for longer lengths.

What is the ambient operating temperature range for the dV/dT filter?

The filter can operate in ambient temperatures from -25°C to 40°C, and is suitable up to 50°C.

What is the voltage drop across the HPS Centurion D1 filter?

The voltage drop across the filter is less than 3%.

What inverter switching and operating frequencies are supported?

The inverter switching frequency is between 2kHz - 4kHz, and the operating frequency is up to 60Hz.

What insulation system temperature ratings are available?

Insulation systems are rated at 130°C for 2A-54A models and 180°C for models greater than 55A.

What is the enclosure type for the HPS Centurion D1 filter?

The filter is available in an Open, Type 1 enclosure.

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and proper operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Immediately after receiving the dV/dT filter, inspect it for any transit damage and ensure it matches the shipping documents. If any damage is found, do not energize the unit and contact the manufacturer.

  2. Mount the filter

    Secure the dV/dT filter to a stable surface or DIN rail using the provided mounting screws. Ensure it is level and firmly attached to prevent movement.

  3. Connect the wiring

    Connect the output phases U, V, and W from the variable frequency drive to terminals A1, B1, and C1 on the dV/dT filter. Connect terminals A2, B2, and C2 to T1, T2, and T3 of the motor, ensuring all connections are tight and secure.

  4. Ground the filter

    Ensure the dV/dT filter is properly grounded according to local codes. Verify that all ground connections are secure before energizing the unit.

  5. Verify connections

    Use a multimeter to check that all electrical connections are tight and that there are no short circuits. Confirm that the unit is dry and free from moisture before proceeding.

  6. Energize the unit

    Once all connections are verified and secure, replace all covers and doors. Turn on the power supply to the dV/dT filter and monitor for any unusual sounds or behaviors.

  7. Calibrate the filter

    Follow the manufacturer's guidelines to calibrate the dV/dT filter settings as necessary for your specific application.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.