ABB Installation Products SSP 1/0 FN 500K Storm-Safe Pin Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral assembly - full neutral…
UPC: 783786753321
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Triplex block configuration for 1/0, 1/0, 1/0 ACSR conductors
- Full neutral assembly for reliable electrical connectivity
- 500 Pound Breakaway Force for enhanced safety and integrity
- Manufactured by ABB - Installation Products
- Designed for demanding overhead power distribution applications
Specifications
Application | Mechanical breakaway link separates service at the pole to prevent damage to utility equi[ment and customer premises |
Insulation | Yes |
Series | SSP |
Size | 1/0 |
Special Features | Crew Safety - The correction is made well below the high-voltage bushings, making it safer for crews to work during a storm outage. Downed-Line Safety - separates at the pole not the weatherhead. The line always comes down de-energized. Quick restoration of power. Simply replace the mechanical breakaway link and reinsert the contacts |
Type | Storm-Safe Pin Kits |
Wire Size | 1/0 ACSR AWG |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.8500 L |
Package Weight (Metric) | 0.3860 kg |

SS1 1/0 FN 750K
Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral assembly - full neutral, breakaway force - 750 Pound Break Force
SSP 4 RN 750K
Storm-Safe Pin Kits, triplex block - 4,4,6, neutral assembly - reduced neutral, breakaway force - 750 Pound Break Force
SSP 4 FN 750K
Storm-Safe Pin Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 750 Pound Break Force
SSP 2 FN 750K
Storm-Safe Pin Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 750 Pound Break Force
SSP 4 FN 500K
Storm-Safe Pin Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 500 Pound Break Force
RA48V
Polycarbonate Insulated Female Disconnect Terminal, Wire Range 0.5-1.5 millimeters squared, Tab Size 4.8mm x 0.5mm
RB48
Polycarbonate Insulated Female Disconnect Non-Brazed with Support Sleeve Wire Range 1.5-2.5 millimeters squared Tab Size 4.8 x .5 mm
ABC 500-22
Aluminum Set-Screw Bar Pedestal Connectors - Double-Row Bar, cable range 6-500, length 2-1/16 inch, width 2-3/4 inch, boot no. FB 33, outlets 4Frequently Asked Questions
What conductor sizes does the SSP 1/0 FN 500K support?
The SSP 1/0 FN 500K is designed for triplex block configurations supporting 1/0, 1/0, 1/0 gauge ACSR conductors.
What is the breakaway force rating for this pin kit?
The ABB Storm-Safe Pin Kits SSP 1/0 FN 500K has a breakaway force rating of 500 pounds.
What type of neutral assembly does this product feature?
This product features a full neutral assembly.
Who is the manufacturer of the Storm-Safe Pin Kits SSP 1/0 FN 500K?
The manufacturer of the Storm-Safe Pin Kits SSP 1/0 FN 500K is ABB - Installation Products.
How to Install the Service Entrance Disconnect System Multiple Service Kit (SSP Series)
This guide provides step-by-step instructions for the safe installation and wiring of the SSP Series Service Entrance Disconnect System, including preparing cables, connecting components, and ensuring proper insulation. Installation must be performed by trained installers.
Estimated time: 1h 30m
Tools needed:
Approved safety cutting device, Crimping tool with 5/8 or equivalent die, Wire strippers, Torque wrench, Insulated gloves rated to appropriate voltage
Supplies needed:
Breakaway link, U-Bolt, CS 2011 Flood-Seal® Insulating rockets, Silicone grease, Compression lugs, Neutral lug, CS 2277 Flood-Seal® insulating rockets, Pin Connectors, Service cables (if replacement needed), Storm-Safe® contact block
- Disconnect Power and Secure Service Drop
WARNING: Danger of Electric Shock! Ensure all applicable local, state, and national electrical codes, installation standards, and safety rules are followed. Disconnect the power cables from the transformer or feed and secure the service drop. Wear insulated gloves rated to the appropriate voltage when working on energized circuits.
- Install Breakaway Link and Contact Block
Open the neutral wedge clamp and install the breakaway link between the wedge clamp and pole hardware. Tighten the service drop as required. Then, install the contact block to the eyebolt using the included U-Bolt and tighten the nuts from the pole side of the contact block.
- Prepare Feed-Side Service Cables
Cut the service cables from the transformer or feed. If the cables are not large enough for multiple loads, replace them with the proper size. Ensure the feed cables have some slack when held alongside the pads to allow the contact block to swing. Cut two CS 2011 Flood-Seal® Insulating rockets at the appropriate ring with an approved safety cutting device and install them on the two hot legs, applying silicone grease to ease installation. Crimp appropriately sized compression lugs onto the three cables using an appropriate crimping tool and listed dies.
- Terminate Feed-Side Neutral and Hot Legs
First, terminate the neutral lug onto the center pad of the contact block, ensuring the barrel is over the pad as shown in the diagram. Torque the connection to 480 in-lb. Next, install one of the hot (energized) legs as per the neutral leg, then slide a Flood-Seal® insulating rocket over the connection. Repeat this process for the other hot leg. Note that a rocket is not required for the Neutral leg.
- Prepare Load-Side Triplex Service Cable
Position the load-side triplex service cable alongside the Storm-Safe® contact block. Ensure the neutral conductor is 6 to 12 inches longer than the phase conductors to ensure it pulls out last in a storm event. Cut two CS 2277 Flood-Seal® insulating rockets at the appropriate ring with an approved safety cutting device and install them on the two load-side hot conductors. Position the load-side cables alongside the pin connectors and mark them at 1/8 inch beyond the knurl mark. Mark and strip the cable. Determine the neutral socket in a reduced neutral configuration. Crimp the Pin Connectors onto the conductors using a 5/8 or equivalent die as shown on the crimp body, filling the crimp body between the knurl marks with crimps spaced 1/8 inch apart (five crimps with a 5/8 die).
- Insert Load-Side Pins into Contact Block
Insert the Neutral Pin into the contact block; the neutral is the center row and is identified with a white marker. The neutral body is oversized and cannot be inserted into a hot leg tower. Then, insert one of the hot leg pins into one of the outer contact block towers. Slide the Flood-Seal® insulating rockets over the towers. Do not use silicone grease for these rockets. Repeat this process for the other services.
- Reconnect Transformer or Feed
Reconnect the transformer or feed. Ensure that the connection to the service is made with the contact block energized but not under load.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.