ABB - Installation Products SSP 2 FN 750K - Storm-Safe Pin Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 750 Pound Break Force

ABB Installation Products SSP 2 FN 750K Storm-Safe Pin Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway…

UPC: 783786753369


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Minimum Qty: 60

Multiplier: 60

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Storm-Safe Pin Kits, SKU SSP 2 FN 750K, are designed for secure and reliable neutral assembly in demanding electrical installations. This triplex block configuration features a full neutral assembly, ensuring proper grounding and system stability. A key specification is its 750 Pound Break Force, indicating robust mechanical integrity capable of withstanding significant stress. This product is manufactured by ABB, a recognized name in installation products, ensuring adherence to quality standards. The Storm-Safe designation implies enhanced resilience against environmental factors, making it suitable for outdoor or exposed applications where reliability is paramount. Its UNSPSC code is 39121447. The triplex block design facilitates efficient wiring and connection management for three-phase systems. The 750 lb break force rating provides a quantifiable measure of its mechanical strength, crucial for applications where external forces or fault conditions might be encountered. This component is essential for maintaining the integrity of electrical distribution systems, particularly in environments prone to adverse weather or physical impact. The full neutral assembly is critical for balanced load distribution and safety.
  • ABB Storm-Safe Triplex Block configuration
  • Full neutral assembly for balanced systems
  • 750 Pound Break Force for mechanical strength
  • Designed for reliable electrical installations
  • Manufacturer: ABB - Installation Products

Specifications

Application
Mechanical breakaway link separates service at the pole to prevent damage to utility equi[ment and customer premises
Insulation
Yes
Special Features
Crew Safety - The correction is made well below the high-voltage bushings, making it safer for crews to work during a storm outage. Downed-Line Safety - separates at the pole not the weatherhead. The line always comes down de-energized. Quick restoration of power. Simply replace the mechanical breakaway link and reinsert the contacts
Type
Storm-Safe Pin Kits
Wire Size
#2 AWG
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.8600 L
Package Weight (Metric)
0.3900 kg
Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 500 Pound Break Force

SS1 2 FN 500K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 500 Pound Break Force
Storm-Safe Pin Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 500 Pound Break Force

SSP 4 FN 500K

Storm-Safe Pin Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 500 Pound Break Force
Polycarbonate Insulated Female Disconnect Terminal, Wire Range 0.5-1.5 millimeters squared, Tab Size 4.8mm x 0.5mm

RA48V

Polycarbonate Insulated Female Disconnect Terminal, Wire Range 0.5-1.5 millimeters squared, Tab Size 4.8mm x 0.5mm
Polycarbonate Insulated Female Disconnect Non-Brazed with Support Sleeve Wire Range 1.5-2.5 millimeters squared Tab Size 4.8 x .5 mm

RB48

Polycarbonate Insulated Female Disconnect Non-Brazed with Support Sleeve Wire Range 1.5-2.5 millimeters squared Tab Size 4.8 x .5 mm
Aluminum Set-Screw Bar Pedestal Connectors - Double-Row Bar, cable range 6-500, length 2-1/16 inch, width 2-3/4 inch, boot no. FB 33, outlets 4

ABC 500-22

Aluminum Set-Screw Bar Pedestal Connectors - Double-Row Bar, cable range 6-500, length 2-1/16 inch, width 2-3/4 inch, boot no. FB 33, outlets 4
Aluminum Lay-In Pedestal Connector Kit, #2-600 kcmil, Aluminum-Copper, (4) Six Conductor Connectors, (24) Keepers and (24) Tin-Plated Aluminum Set Screws, (3) Black PVC Boots and (1) Single Outlet Lug, Contains Oxide Inhibiting Compound and is Stretch Wrapped for shipping. 8.915 inch x 1.25 inch x 1.608 inch.

ABCK 6600 CK W/7191

Aluminum Lay-In Pedestal Connector Kit, #2-600 kcmil, Aluminum-Copper, (4) Six Conductor Connectors, (24) Keepers and (24) Tin-Plated Aluminum Set Screws, (3) Black PVC Boots and (1) Single Outlet Lug, Contains Oxide Inhibiting Compound and is Stretch Wrapped for shipping. 8.915 inch x 1.25 inch x 1.608 inch.
Aluminum Set Screw Bar Pedestal Connector, Dual Rated, ABC Series, In-Line Bar, Conductor Range #12-350, 4 Outlets, BB 10 Yellow Boot

ABC 4350 BB 10YW

Aluminum Set Screw Bar Pedestal Connector, Dual Rated, ABC Series, In-Line Bar, Conductor Range #12-350, 4 Outlets, BB 10 Yellow Boot
Aluminum Lay In Pedestal Connector, 6 Positions, 2-Holes per Conductor, Cable Size 1/0-1000 MCM, Dual Rated for Aluminum and Copper. 11.546 inch long

ABCK 61000 MH

Aluminum Lay In Pedestal Connector, 6 Positions, 2-Holes per Conductor, Cable Size 1/0-1000 MCM, Dual Rated for Aluminum and Copper. 11.546 inch long

Frequently Asked Questions

What conductors are compatible with Storm-Safe systems?

The Blackburn Storm-Safe service entrance breakaway disconnect system is dual rated for use with both aluminum and copper conductors.

What is the breakaway force for SSL 500 link kits?

The SSL 500 link kit has a breakaway force of 500 lbs.

What conductor sizes are supported by SSP 2 FN 750 K?

The SSP 2 FN 750 K pin kit supports #2, #2, #2 ACSR conductors with a full neutral and a 750 lbs breakaway force.

How many pin kits are needed for a three-service base kit?

A three-service base kit (SS 3 K) requires three SSP pin kits.

How many pin kits are needed for a two-service base kit?

A two-service base kit (SS 2 K) requires two SSP pin kits.

What is the breakaway force for SSL 750 link kits?

The SSL 750 link kit has a breakaway force of 750 lbs.

What is included in a single-service breakaway kit?

A single-service kit includes two sockets, one neutral socket, two pin terminals, one neutral pin terminal, one SSL link kit, two Flood-Seal insulating splice covers, and one Flood-Seal insulating rocket.

How does the Storm-Safe system prevent moisture intrusion?

The system uses an internal O-ring to prevent moisture into the contact and external Flood-Seal insulating rockets to seal the entire system from the elements.

What specifications does the Storm-Safe system meet?

The Blackburn Storm-Safe service entrance breakaway disconnect system meets ANSI C119.4-2004 specifications.

What is included in an SSP pin kit?

An SSP pin kit consists of two pin terminals, one neutral pin terminal, one SSL link kit (breakaway link and bail), and two Flood-Seal insulating rockets.

How to Install the SSP Series Service Entrance Disconnect System

This guide provides step-by-step instructions for installing the SSP Series Service Entrance Disconnect System. Ensure all work is performed by trained installers in accordance with all applicable local, state, and national electrical codes, installation standards, and safety rules.

Estimated time: 1h 30m

Tools needed:

Torque wrench, Approved safety cutting device, Appropriate crimping tool, 5/8 crimping die (or equivalent), Insulated gloves (rated to appropriate voltage)

Supplies needed:

CS 2011 Flood-Seal® insulating rockets, Silicone grease, Appropriately sized compression lugs, Pin connectors, CS 2277 Flood-Seal® insulating rockets, Replacement service cables (if needed)

  1. Disconnect Power and Ensure Safety

    WARNING: Danger of Electric Shock! Ensure power cables are disconnected from the transformer or feed and the service drop is secured. This installation must be performed by trained installers in accordance with all applicable electrical codes and safety rules. Wear insulated gloves rated to the appropriate voltage when working on live conductors.

  2. Prepare Service Drop

    Open the neutral wedge clamp and install the breakaway link between the wedge clamp and pole hardware. Tighten the service drop as required.

  3. Mount Contact Block

    Install the contact block to the eyebolt using the included U-Bolt. Tighten the nuts from the pole side of the contact block.

  4. Prepare Feed Cables

    Cut the service cables from the transformer or feed. If existing cables are not large enough for multiple loads, replace them with the proper size. Ensure the feed cables have sufficient slack when held alongside the pads to allow the contact block to swing.

  5. Prepare Feed-Side Hot Leg Insulating Rockets and Lugs

    Cut two CS 2011 Flood-Seal® Insulating rockets at the appropriate ring using an approved safety cutting device. Install these rockets on the two hot legs, applying silicone grease to the cables to ease installation. Crimp appropriately sized compression lugs onto all three cables (two hot, one neutral) using an appropriate crimping tool and listed dies.

  6. Connect Feed-Side Neutral and Hot Legs

    First, terminate the neutral lug onto the center pad of the contact block, ensuring the barrel is over the pad. Torque the connection to 480 in-lb. Next, install one of the hot (energized) legs as per the neutral leg. Slide a Flood-Seal® insulating rocket over this connection. Repeat for the other hot leg. Note: A rocket is not required for the Neutral leg.

  7. Position Load-Side Triplex Service Cable

    Position the load-side triplex service cable alongside the Storm-Safe® contact block. Ensure the neutral conductor is 6 to 12 inches longer than the phase conductors to ensure it pulls out last in a storm event.

  8. Prepare Load-Side Hot Leg Insulating Rockets

    Cut two CS 2277 Flood-Seal® insulating rockets at the appropriate ring with an approved safety cutting device. Install these rockets on the two load-side hot conductors.

  9. Prepare Load-Side Pin Connectors

    Position the load-side cables alongside the pin connectors and mark the cables at 1/8 inch beyond the knurl mark. Mark and strip the cable. If a reduced neutral is present, determine which is the neutral socket. Crimp the Pin Connectors onto the conductors using a 5/8 or equivalent die as shown on the crimp body. Fill the crimp body between the knurl marks with crimps spaced 1/8 inch apart (five crimps with a 5/8 die).

  10. Insert Load-Side Neutral Pin

    Insert the Neutral Pin into the contact block. The neutral is the center row and is identified with a white marker. The neutral body is oversized and cannot be inserted into a hot leg tower.

  11. Insert Load-Side Hot Leg Pins

    Insert one of the hot leg pins into one of the outer contact block towers. Slide the Flood-Seal® insulating rockets over the towers. Do not use silicone grease for these rockets. Repeat this process for the other services. Note: A rocket is not required for the Neutral leg.

  12. Reconnect Power

    Reconnect the transformer or feed to restore power to the system.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.